BS5308 Instrumentation Cable Part 1 Type 2
Eland Product Group: A3I
Application: BS5308 cables are used to carry voice and data services, they also serve as the interconnection between electrical equipment and instruments, particularly in and around process plants, where transducer generated signals are transmitted through to panels, controllers and other devices.
Standards: BS5308 Part 1, BS EN/IEC 60228
Conductor: Class 1 solid, class 2 stranded or class 5 flexible plain copper to BS EN 60228:2005 (previously BS6360)
Pairing: Two insulated conductors uniformly twisted together with a lay not exceeding 100mm
Insulation: PE (Polyethylene) to BS6234 or XLPE (Cross Linked Polyethylene) to BS5308 or LSZH (Low Smoke Zero Halogen).
Drain wire: Tinned copper
Screen:
Individually Screened Pairs:
Aluminium/polyester tape is applied to each pair, metallic side down and in continuous contact with a 0.5mm² tinned copper drain wire
Collectively Screened Cables:
Aluminium/polyester tape is applied over the laid up pairs metallic side down and in continuous contact with a 0.5mm² tinned copper drain wire
Bedding: PE (Polyethylene) to BS6234
Armouring: GSWA (Galvanised Steel Wire Armour) to BS1442
Sheath: PVC (Polyvinyl Chloride) to BS7655 or LSZH (Low Smoke Zero Halogen)
Sheath Colour: Blue or Black
Voltage Rating: 300/500V
Temperature Rating:
Fixed: -30°C to + 70°C
Flexing: -5°C to + 50°C
Pair Identification - Individually Pair Screened: See Pair Identification table on page 2 of the data-sheet pdf
Note: These cables are not suitable for direct connection to the public mains supply
For more information please consult a member of the Sales Team.
BS5308 Instrumentation Cable Part 1 Type 2
| Eland Part Number |
No. of Pairs x Nominal Cross Sectional Area # x mm2 |
Nominal No. and Nominal Diameter of Strands #/mm |
Nominal Overall Diameter mm |
|---|---|---|---|
| A3I0105CP1T2* | 1 x 0.50 | 16/0.2 | 11.4 |
| A3I0175CP1T2* | 1 x 0.75** | 24/0.2 | 11.7 |
| A3I0110CP1T2* | 1 x 1.00 | 1/1.13 | 11.8 |
| A3I0115CP1T2* | 1 x 1.50 | 7/0.53 | 12.9 |
| A3I0205CP1T2* | 2 x 0.50 | 16/0.2 | 12.3 |
| A3I0275CP1T2* | 2 x 0.75** | 24/0.2 | 12.9 |
| A3I0210CP1T2* | 2 x 1.00 | 1/1.13 | 13.0 |
| A3I0215CP1T2* | 2 x 1.50 | 7/0.53 | 14.3 |
| A3I0505CP1T2* | 5 x 0.50 | 16/0.2 | 17.9 |
| A3I0575CP1T2* | 5 x 0.75** | 24/0.2 | 19.8 |
| A3I0510CP1T2* | 5 x 1.00 | 1/1.13 | 19.7 |
| A3I0515CP1T2* | 5 x 1.50 | 7/0.53 | 22.1 |
| A3I1005CP1T2* | 10 x 0.50 | 16/0.2 | 22.9 |
| A3I1075CP1T2* | 10 x 0.75** | 24/0.2 | 25.3 |
| A3I1010CP1T2* | 10 x 1.00 | 1/1.13 | 24.3 |
| A3I1015CP1T2* | 10 x 1.50 | 7/0.53 | 28.4 |
| A3I2005CP1T2* | 20 x 0.50 | 16/0.2 | 29.1 |
| A3I2075CP1T2* | 20 x 0.75** | 24/0.2 | 31.3 |
| A3I2010CP1T2* | 20 x 1.00 | 1/1.13 | 31.2 |
| A3I2015CP1T2* | 20 x 1.50 | 7/0.53 | 36.5 |
| A3I3005CP1T2* | 30 x 0.50 | 16/0.2 | 33.9 |
| A3I3075CP1T2* | 30 x 0.75** | 24/0.2 | 37.5 |
| A3I3010CP1T2* | 30 x 1.00 | 1/1.13 | 36.2 |
| A3I3015CP1T2* | 30 x 1.50 | 7/0.53 | 42.5 |
| A3I5005CP1T2* | 50 x 0.50 | 16/0.2 | 42.1 |
| A3I5075CP1T2* | 50 x 0.75** | 24/0.2 | 47.0 |
| A3I5010CP1T2* | 50 x 1.00 | 1/1.13 | 45.7 |
| A3I5015CP1T2* | 50 x 1.50 | 7/0.53 | 53.4 |
| A3I0205IP1T2* | 2 x 0.50 | 16/0.2 | 16.8 |
| A3I0275CP1T2* | 2 x 0.75** | 24/0.2 | 17.6 |
| A3I0210CP1T2* | 2 x 1.00 | 1/1.13 | 17.6 |
| A3I0215CP1T2* | 2 x 1.50 | 7/0.53 | 20.4 |
| A3I0505CP1T2* | 5 x 0.50 | 16/0.2 | 20.9 |
| A3I0575CP1T2* | 5 x 0.75** | 24/0.2 | 22.0 |
| A3I0510CP1T2* | 5 x 1.00 | 1/1.13 | 21.9 |
| A3I0515CP1T2* | 5 x 1.50 | 7/0.53 | 25.4 |
| A3I1005CP1T2* | 10 x 0.50 | 16/0.2 | 27.9 |
| A3I1075CP1T2* | 10 x 0.75** | 24/0.2 | 29.5 |
| A3I1010CP1T2* | 10 x 1.00 | 1/1.13 | 29.4 |
| A3I1015CP1T2* | 10 x 1.50 | 7/0.53 | 33.5 |
| A3I2005CP1T2* | 20 x 0.50 | 16/0.2 | 34.3 |
| A3I2075CP1T2* | 20 x 0.75** | 24/0.2 | 37.8 |
| A3I2010CP1T2* | 20 x 1.00 | 1/1.13 | 37.8 |
| A3I2015CP1T2* | 20 x 1.50 | 7/0.53 | 42.6 |
| A3I3005CP1T2* | 30 x 0.50 | 16/0.2 | 40.5 |
| A3I3075CP1T2* | 30 x 0.75** | 24/0.2 | 43.9 |
| A3I3010CP1T2* | 30 x 1.00 | 1/1.13 | 43.8 |
| A3I3015CP1T2* | 30 x 1.50 | 7/0.53 | 50.8 |
| A3I5005CP1T2* | 50 x 0.50 | 16/0.2 | 51.5 |
| A3I5075CP1T2* | 50 x 0.75** | 24/0.2 | 55.0 |
| A3I5010CP1T2* | 50 x 1.00 | 1/1.13 | 54.9 |
| A3I5015CP1T2* | 50 x 1.50 | 7/0.53 | 62.6 |