BS5467 Cable

SWA Cable - BS5467 Steel Wire Armoured PVC

BASECRestriction of the use of Hazardous SubstancesBritish Standards InstituteInternational Electrotechnical Commission

Eland Product Group: A9S

Application: SWA Cable - power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting.

Standards: BS5467, IEC 60502

Conductor: Class 2 stranded plain copper conductor to BS EN 60228:2005 (previously BS6360)

Insulation: XLPE (Cross-Linked Polyethylene)

Bedding: PVC (Polyvinyl Chloride)

Armouring:
Single Core: AWA (Aluminium Wire Armour)
Multi Core: SWA (Steel Wire Armour)

Sheath: PVC (Polyvinyl Chloride)

Sheath Colour: Black

Voltage Rating: 600/1000V

Temperature Rating: 0°C to +90°C

Minimum Bending Radius:
1.5mm² - 16mm²:
6 x overall diameter

25mm² and above:
8 x overall diameter

Core Identification:
1 Core: Brown
2 Cores: Brown, Blue
3 Cores: Brown, Black, Grey
4 Cores: Blue, Brown, Black, Grey;
5 Cores: Green/Yellow, Blue, Brown, Black, Grey
Alternative core identification: White Cores with Black numbers

For more information please consult a member of the Sales Team.

SWA Cable - BS5467 Steel Wire Armoured PVC

Eland Part Number
No. of Cores x Nominal Cross Sectional Area
# x mm2
Nominal Overall Diameter
mm
A9AWA150 1 x 50.0 17.5
A9AWA170 1 x 70.0 20.2
A9AWA195 1 x 95.0 22.3
A9AWA1120 1 x 120.0 24.2
A9AWA1150 1 x 150.0 27.4
A9AWA1185 1 x 185.0 30.0
A9AWA1240 1 x 240.0 32.8
A9AWA1300 1 x 300.0 35.6
A9AWA1400 1 x 400.0 40.4
A9AWA1500 1 x 500.0 44.2
A9AWA1630 1 x 630.0 48.8
A9AWA1800 1 x 800.0 55.4
A9AWA1800 1 x 1000.0 60.6
A9SWA2015 2 x 1.5 12.1
A9SWA2025 2 x 2.5 13.6
A9SWA2040 2 x 4.0 14.7
A9SWA2060 2 x 6.0 15.9
A9SWA210 2 x 10.0 18.0
A9SWA216 2 x 16.0 20.4
A9SWA225 2 x 25.0 20.4
A9SWA235 2 x 35.0 23.3
A9SWA250 2 x 50.0 25.8
A9SWA270 2 x 70.0 29.0
A9SWA295 2 x 95.0 33.1
A9SWA2120 2 x 120.0 36.1
A9SWA2150 2 x 150.0 39.3
A9SWA3015 3 x 1.5 12.6
A9SWA3025 3 x 2.5 14.1
A9SWA3040 3 x 4.0 15.3
A9SWA3060 3 x 6.0 16.6
A9SWA310 3 x 10.0 19.5
A9SWA316 3 x 16.0 21.6
A9SWA325 3 x 25.0 25.5
A9SWA335 3 x 35.0 28.0
A9SWA350 3 x 50.0 28.5
A9SWA370 3 x 70.0 32.2
A9SWA395 3 x 95.0 37.0
A9SWA3120 3 x 120.0 40.4
A9SWA3150 3 x 150.0 45.5
A9SWA3185 3 x 185.0 49.8
A9SWA3240 3 x 240.0 55.1
A9SWA3300 3 x 300.0 60.2
A9SWA3400 3 x 400.0 66.6
A9SWA4015 4 x 1.5 13.5
A9SWA4025 4 x 2.5 15.0
A9SWA4040 4 x 4.0 16.4
A9SWA4060 4 x 6.0 18.7
A9SWA410 4 x 10.0 21.1
A9SWA416 4 x 16.0 22.9
A9SWA425 4 x 25.0 27.6
A9SWA435 4 x 35.0 30.4
A9SWA450 4 x 50.0 32.0
A9SWA470 4 x 70.0 37.7
A9SWA495 4 x 95.0 41.7
A9SWA4120 4 x 120.0 47.1
A9SWA4150 4 x 150.0 51.4
A9SWA4185 4 x 185.0 56.6
A9SWA4240 4 x 240.0 63.0
A9SWA4300 4 x 300.0 68.8
A9SWA4400 4 x 400.0 78.1
A9SWA5015 5 x 1.5 14.3
A9SWA5025 5 x 2.5 16.3
A9SWA5040 5 x 4.0 17.8
A9SWA5060 5 x 6.0 20.0
A9SWA510 5 x 10.0 22.9
A9SWA516 5 x 16.0 26.6
A9SWA525 5 x 25.0 31.5
A9SWA535 5 x 35.0 34.8
A9SWA550 5 x 50.0 40.4
A9SWA0715 7 x 1.5 15.2
A9SWA7025 7 x 2.5 17.1
A9SWA1215 12 x 1.5 19.4
A9SWA12025 12 x 2.5 22.4
A9SWA1915 19 x 1.5 22.2
A9SWA1925 19 x 2.5 26.6
A9SWA2715 27 x 1.5 26.7
A9SWA2725 27 x 2.5 30.7
A9SWA3715 37 x 1.5 29.0
A9SWA3725 37 x 2.5 33.8

Copper Tube Terminals

Copper Tube Terminals

Cable Gland CW

Cable Gland CW

Cable Gland BW

Cable Gland BW