BS6500 Cable
YY LSZH Control Flexible Cable to BS6500
Eland Product Group: A5L
Application: For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
Standards: Generally to BS6500, VDE0250, IEC 60332-3, IEC 60754-1
Conductor: Class 5 flexible plain copper conductors to BS EN 60228:2005 (previously BS6360), DIN VDE 0295:1995-06 or IEC 60228
Insulation: XLPE (Cross-Linked Polyethylene)
Sheath: LSZH (Low Smoke Zero Halogen)
Sheath Colour: Grey
Voltage Rating: 300/500V
Temperature Rating:
Fixed: -35°C to +85°C
Flexing: -5°C to +85°C
Minimum Bending Radius: 10 x overall diameter
Core Identification: Black with White numbers. (3 cores and above to include Green/Yellow). Coloured cores available.
For more information please consult a member of the Sales Team.
YY LSZH Control Flexible Cable to BS6500
| Eland Part Number |
No. of Cores x Nominal Cross Sectional Area # x mm² |
Nominal Overall Diameter mm |
|---|---|---|
| A5L020005 | 2 x 0.50 | 5.20 |
| A5L020075 | 2 x 0.75 | 5.70 |
| A5L02010 | 2 x 1.00 | 5.90 |
| A5L02015 | 2 x 1.50 | 7.10 |
| A5L02025 | 2 x 2.50 | 8.30 |
| A5L030005 | 3 x 0.50 | 5.50 |
| A5L030075 | 3 x 0.75 | 6.04 |
| A5L03010 | 3 x 1.00 | 6.26 |
| A5L03015 | 3 x 1.50 | 7.54 |
| A5L03025 | 3 x 2.50 | 9.04 |
| A5L03040 | 3 x 4.00 | 10.40 |
| A5L03060 | 3 x 6.00 | 11.90 |
| A5L0310 | 3 x 10.00 | 14.70 |
| A5L0316 | 3 x 16.00 | 17.70 |
| A5L040005 | 4 x 0.50 | 5.98 |
| A5L040075 | 4 x 0.75 | 6.58 |
| A5L04010 | 4 x 1.00 | 7.02 |
| A5L04015 | 4 x 1.50 | 8.23 |
| A5L04025 | 4 x 2.50 | 9.87 |
| A5L04040 | 4 x 4.00 | 11.40 |
| A5L04060 | 4 x 6.00 | 13.30 |
| A5L0410 | 4 x 10.00 | 16.60 |
| A5L0416 | 4 x 16.00 | 19.70 |
| A5L050005 | 5 x 0.50 | 6.53 |
| A5L050075 | 5 x 0.75 | 7.41 |
| A5L05010 | 5 x 1.00 | 7.68 |
| A5L05015 | 5 x 1.50 | 9.23 |
| A5L05025 | 5 x 2.50 | 11.05 |
| A5L05040 | 5 x 4.00 | 12.90 |
| A5L05060 | 5 x 6.00 | 14.80 |
| A5L0510 | 5 x 10.00 | 18.20 |
| A5L0516 | 5 x 16.00 | 21.70 |
| A5L0525 | 5 x 25.00 | 26.70 |
| A5L070005 | 7 x 0.50 | 7.30 |
| A5L070075 | 7 x 0.75 | 8.05 |
| A5L07010 | 7 x 1.00 | 8.55 |
| A5L07015 | 7 x 1.50 | 10.05 |
| A5L07025 | 7 x 2.50 | 12.25 |
| A5L10005 | 12 x 0.50 | 9.70 |
| A5L120075 | 12 x 0.75 | 10.94 |
| A5L12010 | 12 x 1.00 | 11.36 |
| A5L12015 | 12 x 1.50 | 13.00 |
| A5L12025 | 12 x 2.50 | 16.54 |
| A5L180005 | 18 x 0.50 | 11.50 |
| A5L18075 | 18 x 0.75 | 12.95 |
| A5L18010 | 18 x 1.00 | 13.65 |
| A5L18015 | 18 x 1.50 | 15.61 |
| A5L18025 | 18 x 2.50 | 19.75 |
| A5L250005 | 25 x 0.50 | 13.80 |
| A5L250075 | 25 x 0.75 | 15.50 |
| A5L25010 | 25 x 1.00 | 16.10 |
| A5L25015 | 25 x 1.50 | 19.50 |
| A5L25025 | 25 x 2.50 | 23.50 |