BS6500 Cable

SY Control Flexible Cable to BS6500

Restriction of the use of Hazardous SubstancesBritish Standards InstituteVDE (Verband der Elektrotechnik Elektronik Informationstechnik e.V.)

Eland Product Group: A5J

Application: Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
The braided screen offers the best possible protection against mechanical damage and offers a level of Electro-magnetic shielding. The galvanised coating helps protect against corrosion.

Standards: Generally to BS6500, VDE0250

Conductor: Class 5 flexible annealed plain copper conductors to BS EN 60228:2005 (previously BS6360), VDE0295, IEC 60228

Insulation: PVC (Polyvinyl Chloride) Type TI 2 complying with BS EN 50363-3:2005

Bedding: PVC (Polyvinyl Chloride) TM2 as specified in BS EN 50363-4-1:2005

Braiding: GSWB (Galvanised Steel Wire Braid)
Minimum coverage of braiding shall be 50%

Sheath: PVC (Polyvinyl Chloride) conforming to TM 2 as specified in BS EN 50363-4-1:2005

Sheath Colour: Transparent

Voltage Rating: 300/500V

Operating Temperature: -15°C to +70°C

Minimum Bending Radius: 10 x overall diameter

Short Circuit Temperature: +160°C

Core Identification: Black with White numbers. (3 cores and above to include Green/Yellow). Coloured cores available.

Note: SY Cables are not suitable for direct connection to the public mains supply.

For more information please consult a member of the Sales Team.

SY Control Flexible Cable to BS6500

Eland Part Number
No. of Cores x Nominal Cross Sectional Area
# x mm²
Nominal Overall Diameter
mm
FCGCXT Gland
A5J20075 2 x 0.75 7.2 20S
A5J2010 2 x 1.00 7.6 20S
A5J2015 2 x 1.50 8.4 20S
A5J30075 3 x 0.75 7.5 20S
A5J3010 3 x 1.00 7.9 20S
A5J3015 3 x 1.50 8.8 20S
A5J3025 3 x 2.50 10.3 20S
A5J3040 3 x 4.00 11.9 20
A5J3060 3 x 6.00 13.8 25
A5J310 3 x 10.00 16.8 25
A5J316 3 x 16.00 19.8 25/32
A5J325 3 x 25.00 24.2 32
A5J335 3 x 35.00 26.3 40
A5J40075 4 x 0.75 8.1 20S
A5J4010 4 x 1.00 8.7 20S
A5J4015 4 x 1.50 9.4 20S
A5J4025 4 x 2.50 11.1 20S
A5J4040 4 x 4.00 12.9 20
A5J4060 4 x 6.00 15.0 25
A5J410 4 x 10.00 18.3 25
A5J416 4 x 16.00 21.9 32
A5J425 4 x 25.00 26.4 40
A5J435 4 x 35.00 30.2 40
A5J450 4 x 50.00 34.3 50S
A5J470 4 x 70.00 38.5 50
A5J495 4 x 95.00 43.0 50
A5J50075 5 x 0.75 8.9 20S
A5J5010 5 x 1.00 9.4 20S
A5J5015 5 x 1.50 10.4 20S
A5J5025 5 x 2.50 12.2 20
A5J5040 5 x 4.00 13.9 25
A5J5060 5 x 6.00 16.5 25
A5J510 5 x 10.00 20.0 32
A5J516 5 x 16.00 23.9 32
A5J525 5 x 25.00 28.8 40
A5J535 5 x 35.00 32.7 50S
A5J70075 7 x 0.75 9.5 20S
A5J7010 7 x 1.00 10.4 20S
A5J7015 7 x 1.50 11.7 20
A5J7025 7 x 2.50 13.5 20
A5J80075 8 x 0.75 10.5 20S
A5J8010 8 x 1.00 10.8 20S
A5J8015 8 x 1.50 12.4 20
A5J12075 12 x 0.75 13.0 20
A5J12010 12 x 1.00 13.2 20
A5J02515 12 X 1.50 15.1 25
A5J12025 12 x 2.50 17.6 25
A5J180075 18 x 0.75 15.0 25
A5J18010 18 x 1.00 15.9 25
A5J18015 18 x 1.50 17.6 25
A5J18025 18 x 2.50 20.6 32
A5J250075 25 x 0.75 17.6 25
A5J25010 25 x 1.00 18.4 25
A5J1215 25 x 1.5 20.6 32
A5J2525 25 x 2.50 24.2 32