Cable Genius

Cable Standards

 

BS5308 Part 1Insulated intrinsically safe instrumentation cables.
BS5308 Cable Part 1 Type 1>
BS5308 Part 2Insulated intrinsically safe instrumentation cables.
BS5308 Cable Part 1 Type 2>
BS5467Power Cables, armoured thermosetting-polymer insulated, for electricty supply.
Steel Wire Armoured (SWA) BS5467 Cable PVC>
BS6004Insulated cables, PVC insulated, non-armoured.
Cables to BS6004>
BS6231 : 2006Electric cables. Single core PVC insulated flexible cables of rated voltage 600/1000 V for switchgear and control gear wiring.
Tri-rated Cable to BS6231>
BS638 : Pt4 : 1996Arc welding power sources, equipment and accessories. Specification for welding cables.
Cables to BS638>
BS6500 : 2000Electric cables. Flexible cords rated up to 300/500 V, for use with appliances and equipment intended for domestic, office and similar environments.
Cables to BS6500>
BS6622 : 1999Cables with extruded cross linked polyethylene or ethylene propylene rubber insulation 3.8/6.6kV to19/33kV.
Cables to BS6622>
BS6724 : 1997600/1000V,1900/3300V armoured electric cable with thermosetting insulation and low emission smoke, gases. Power Cables, armoured thermosetting-polymer insulated, for electricty supply.
Steel Wire Armoured (SWA) BS6724 Cable LSZH>
BS7211 : 1998Thermosetting insulated cables, non armoured, with low smoke and gas.
Cables to BS7211>
BS7835Specification for armoured cables with extruded cross-linked polyethylene or ethylene propylene rubber insulation for rated voltages from 3.8/6.6 kV up to 19/33 kV having low emission of smoke and corrosive gases when affected by fire.
Cables to BS7835>
BS7919 : 2001Electric cables. Flexible cables rated up to 450/750V, for use with appliances and equipment intended for industrial and similar environments.
Cables to BS7919>
BS125Electric conductors, copper and copper-cadmium, for overhead transmission
BS215Electric conductors, aluminium and steel-cored aluminium
BS4066Electric cables, tests under fire conditions
BS 2 E 21Pren type electric cables for aircraft
BS6007 : 2006Electric cables. Single core unsheathed heat resisting cables for voltages up to and including 450/750 V, for internal wiring
BS6141 : 1991Flexible conductors, for high temperature zones - this standard has been withdrawn and replaced by tables in BS 6004:2000, BS 6007:2000, BS 6500:2000 and BS 7919:2001
BS6195 : 2006Electric cables. Rubber or silicone rubber insulated flexible cables and cords for coil end leads
BS6346 : 1997Electric cables. PVC insulated, armoured cables for voltages of 600/1000 V and 1900/3300 V
BS6360 : 1991Specification for conductors in insulated cables and cords . This standard is obsolescent and will be replaced by BS EN 60228
BS6469 : section 99.1 : 1992insulating, sheathing materials of electric cables, non electrical tests
BS6480Specification for impregnated paper-insulated lead or lead alloy sheathed electric cables of rated voltages up to and including 33000 V
BS6883 : 1999Elastomer insulated cables for fixed wiring in ship.
BS60228 : 2005Conductors of insulated cables
BS7629 PART 1Specification for 300/500V fire resistant electric cable having low emission of smoke and corrosive gases when affected by fire - multicore Cables
BS7629 PART 2Specification for 300/500V fire resistant electric cable having low emission of smoke and corrosive gases when affected by fire - multipair Cables
BS7870LV and MV polymeric insulated cables for use by distribution and generation utilities. General
BS7889Electric cables. Thermosetting insulated, unarmoured cables for a voltage of 600/1000 V
BS7884 : 1997Specification for copper and copper-cadmium stranded conductors for overhead electric traction and power transmission systems
DIN VDE 262XLPE insulated and PVC sheathed installation cable up to 0.6/1kV
DIN VDE 266 Part 3 and 4Halogen free cables with improved characteristics in the case of fire - nuclear power plants
DIN VDE 267Halogen free cables with improved characteristics in the case of fire - nominal voltages 6 to 30kV
DIN VDE 271PVC insulated cables rated voltages up to and including 3.6/6 (7.2)kV
DIN VDE 276 Part 603Distribution cables of nominal voltages Uo/U 0.6/1kV
DIN VDE 276 part 604Power cables of nominal voltages Uo/U 0.6/1kV with special fire performance for use in power stations
DIN VDE 276 part 604/605Additional test methods
DIN VDE 276 part 620Distribution cables of nominal voltages Uo/U 3.6kV to 20.8/36kV
DIN VDE 277Airport Lighting
DIN VDE 281 part 1 to part 404PVC cables, wires and flexible cords for power installation
DIN VDE 282 part 1 to part 808Rubber cables and flexible cords for power installation, heat resistant silicon rubber insulated cable, halogen free insulated cable, arc welding cable, rubber insulated lift cable, rubber sheathed flexible cables
EIA RS 232TIA/EIA standard for serial transmission between computers and peripheral devices
RS 422Electrical characteristics of the balanced voltage digital interface circuit
TIA/EIA 568Commercial Building Telecommunications Wiring Standard Part 1 : General Requirements
BS6121Mechanical cable glands
CSA 22.2 No 127 Type TEWEquipment and Lead Wires
CW1128Specification CW 1128 for cable polyethylene twin and polyethylene twin - screened
Generally to BS6004Insulated cables, PVC insulated, non-armoured
Generally to BS6500Flexible cables, insulated cords and cables
H03VV-FCircular, PVC insulation/PVC sheathed, 300/300V, to BS6500.
H05BN4-FSingle Core, Rubber Insulated, HOFR Sheathed, 450/750V
H05V-KSingle Core, PVC Insulated Only, 300/300V
H05VV-FPVC Insulated and Sheathed, 300/500V
H07BN4-FSingle Core, Rubber Insulated, HOFR Sheathed, 450/750V
H07V-KSingle Core, PVC Insulated Only, 450/750V, Flexible Conductor
H07V-RSingle Core, PVC Insulated Only, 450/750V, Stranded Conductor
IEC60598-1Luminaires - General requirements and tests
UL 758Appliance Wiring Material
DIN VDE 250 Part 1 to Part 819Cables, wires and flexible cords for power installation