BS6195 Cable

Coil End Lead Cable to BS6195

Restriction of the use of Hazardous SubstancesBritish Standards Institute

Eland Product Group: A6K

Application: Coil leads are used mainly in electrical machinery and panel wiring. The HOFR sheath resists oil and varnish and the stranding is designed as a compromise between flexibility and positional stability. Also suitable as an alternative to tri-rated and bi-rated cable in certain applications.

Standards: BS6195 Type 4

Conductor: Class 5 flexible tinned copper to BS EN 60228:2005 (previously BS6360)

Separator: PETP (Polyethelene Terephthalate) tape

Insulation:
4A, 4C: EPR-HOFR (Ethylene Propylene Rubber - Heat and Oil Resistant and Flame Retardant) Type FR1 to BS7655

4D, 4E, 4F: EPR-HOFR (Ethylene Propylene Rubber - Heat and Oil Resistant and Flame Retardant) Type FR2 to BS7655

Sheath: CPE (Chlorinated Polyethylene) rubber compound

Sheath Colour: Black

Voltage Rating:
Type 4A: 300/500V
Type 4C: 600/1000V
Type 4D: 1900/3300V
Type 4E: 3800/6600V
Type 4F: 6350/11000V

Temperature Rating: -30°C to +90°C

Minimum bending radius: 4 x overall diameter

For more information please consult a member of the Sales Team.

Coil End Lead Cable to BS6195

Eland Part Number
Cable Type - No. of Cores x Nominal Cross Sectional Area
# x mm²
Cable Type
Overall Diameter Max.
mm
A6K00075A 1 x 0.75 4A 3.5
A6K0010A 1 x 1.00 4A 3.7
A6K0015A 1 x 1.50 4A 4.0
A6K0025A 1 x 2.50 4A 4.6
A6K0040A 1 x 4.00 4A 5.4
A6K006A 1 x 6.00 4A 6.5
A6K010A 1 x 10.00 4A 7.9
A6K0010 1 x 1.00 4C 4.9
A6K0015 1 x 1.50 4C 5.2
A6K0025 1 x 2.50 4C 5.6
A6K0040 1 x 4.00 4C 6.3
A6K006 1 x 6.00 4C 7.5
A6K010 1 x 10.00 4C 8.5
A6K016 1 x 16.00 4C 9.6
A6K025 1 x 25.00 4C 11.4
A6K035 1 x 35.00 4C 12.8
A6K050 1 x 50.00 4C 14.8
A6K070 1 x 70.00 4C 17.2
A6K095 1 x 95.00 4C 19.7
A6K120 1 x 120.00 4C 21.9
A6K150 1 x 150.00 4C 24.1
A6K185 1 x 185.00 4C 26.3
A6K240 1 x 240.00 4C 28.3
A6K300 1 x 300.00 4C 33.0
A6K400 1 x 400.00 4C 37.4
A6K0025D 1 x 2.50 4D 8.5
A6K0040D 1 x 4.00 4D 9.1
A6K006D 1 x 6.00 4D 10.3
A6K010D 1 x 10.00 4D 11.3
A6K016D 1 x 16.00 4D 12.4
A6K025D 1 x 25.00 4D 13.8
A6K035D 1 x 35.00 4D 15.2
A6K050D 1 x 50.00 4D 17.1
A6K070D 1 x 70.00 4D 19.2
A6K095D 1 x 95.00 4D 22.0
A6K120D 1 x 120.00 4D 23.5
A6K150D 1 x 150.00 4D 25.5
A6K185D 1 x 185.00 4D 27.5
A6K240D 1 x 240.00 4D 30.6
A6K300D 1 x 300.00 4D 33.8
A6K400D 1 x 400.00 4D 37.8
A6K016E 1 x 16.00 4E 17.2
A6K025E 1 x 25.00 4E 18.6
A6K035E 1 x 35.00 4E 20.0
A6K050E 1 x 50.00 4E 22.1
A6K070E 1 x 70.00 4E 24.2
A6K095E 1 x 95.00 4E 26.3
A6K120E 1 x 120.00 4E 27.8
A6K150E 1 x 150.00 4E 29.8
A6K185E 1 x 185.00 4E 32.1
A6K240E 1 x 240.00 4E 35.1
A6K025F 1 x 25.00 4F 24.1
A6K035F 1 x 35.00 4F 25.5
A6K050F 1 x 50.00 4F 27.3
A6K070F 1 x 70.00 4F 29.4
A6K095F 1 x 95.00 4F 31.5
A6K120F 1 x 120.00 4F 33.3
A6K150F 1 x 150.00 4F 35.3
A6K185F 1 x 185.00 4F 37.3
A6K240F 1 x 240.00 4F 40.3