International Standard Cables
Eland Cables stocks a comprehensive range of cables to national and international standards. Our international cables conform to standards such as BASEC, HAR, BSI, IEC, CSA, CENELEC, UL and VDE. International Standards give buyers the reassurance that a product has the standard of performance and high quality that they expect.
H01N2-D Welding Cable to BS638
Toggle
Eland Product Group: A2G
Application: For the transmission of high currents from the electric welding machine to the welding tool. Suitable for flexible use under rough conditions, on assembly lines and conveyor systems, in machine tool and motor car manufacturing, ship building, for manually and automatically operated line and spot welding machines.
Standards: BS638 Part 4, VDE0282-6, CENELEC HD22.6
H01N2-E Welding Cable to BS638
Toggle
Eland Product Group: A2G
Application: For the transmission of high currents from the electric welding machine to the welding tool. Suitable for flexible use under rough conditions, on assembly lines and conveyor systems, in machine tool and motor car manufacturing, ship building, for manually and automatically operated line and spot welding machines.
Standards: BS638 Part 4, DIN VDE 0282-6, CENELEC HD22.6
H07RN-F Cable to BS7919
Toggle
Eland Product Group: A6G and A5G
Application: These cables are designed to provide high flexibility and have
the capacity to withstand weather,
oils/greases, mechanical and thermal stresses. Applications include handling equipment, mobile power supplies, worksites, stage and audio visual equipment, port areas and dams. Also for use in drainage and water treatment, cold environments and severe industrial environments.
Read more about H07RN-F Cables and their applications.
Standards: BS7919, CENELEC HD22.4 S4
Tri-rated Cable (H07V2-K) to BS6231
Toggle
Eland Product Group: A2T
Application: Tri-rated Cable panel wiring is a high temperature, flame retardant cable designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers. Tri-rated Cable is sometimes referred to as BS6231 Cable, H07V2-K or Panel Wire.
Standards:
BS6231 Type CK
UL Subj.758
CSA C22.2 No. 210
HD 21.7 S2*
0361TQ Orange Welding Cable to BS638
Toggle
Eland Product Group: A1E
Application: For the transmission of high currents from the electric welding machine to the welding tool. Suitable for flexible use under rough conditions, on assembly lines and conveyor systems, in machine tool and motor car manufacturing, ship building, for manually and automatically operated line and spot welding machines.
Standards: BS638 Part 4* BS EN 60332-1-2
0361TQ Black Welding Cable to BS638
Toggle
Eland Product Group: A1G
Application: For the transmission of high currents from the electric welding machine to the welding tool. Suitable for flexible use under rough conditions, on assembly lines and conveyor systems, in machine tool and motor car manufacturing, ship building, for manually and automatically operated line and spot welding machines.
Standards: BS638 Part 4* BS EN 60332-1-2
Coil End Lead Cable to BS6195
Toggle
Eland Product Group: A6K
Application: Coil leads are used mainly in electrical machinery and panel wiring. The HOFR sheath resists oil and varnish and the stranding is designed as a compromise between flexibility and positional stability. Also suitable as an alternative to tri-rated and bi-rated cable in certain applications.
Standards: BS6195 Type 4
SWA Cable - BS5467 Steel Wire Armoured PVC
Toggle
Eland Product Group: A9S
Application: SWA Cable - power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting.
Standards: BS5467, IEC 60502
SWA Cable - BS6724 Steel Wire Armoured LSZH
Toggle
Eland Product Group: A9L
Application: SWA Cable - power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment.
Standards: BS6724, IEC 60754-1
CY Control Flexible Cable to BS6500
Toggle
Eland Product Group: A5C
Application: Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use when temporarily moved, and in conditions of medium mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
Standards: Generally to BS6500
CY LSZH Control Flexible Cable to BS6500
Toggle
Eland Product Group: A5B
Application: For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use when temporarily moved, and in conditions of medium mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
Standards: Generally to BS6500, IEC 60754-1
SY Control Flexible Cable to BS6500
Toggle
Eland Product Group: A5J
Application: Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
The braided screen offers the best possible protection against mechanical damage and offers a level of Electro-magnetic shielding. The galvanised coating helps protect against corrosion.
Standards: Generally to BS6500, VDE0250
YY Control Flexible Cable to BS6500
Toggle
Eland Product Group: A5Y
Application: Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
Standards: Generally to BS6500, VDE0250
YY LSZH Control Flexible Cable to BS6500
Toggle
Eland Product Group: A5L
Application: For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
Standards: Generally to BS6500, VDE0250, IEC 60332-3, IEC 60754-1
NYY-J Cable
Toggle
Eland Product Group: A9N
Application: Power and control cable for fixed installation. Can be used indoors, outdoors, underground, in concrete and in water.
Standards: IEC60502-1
Generally to VDE0276 and VDE0271.
BS5308 Instrumentation Cable Part 1 Type 2
Toggle
Eland Product Group: I
Application: BS5308 cables are designed to carry communication and control signals in a variety of installation types including those found in the petrochemical industry. The signals can be of analogue, data or voice type and from a variety of transducers such as pressure, proximity or microphone. BS 5308 cables are designed to form part of an intrinsically safe system and the technical information required to determine their suitability for this application is contained within the datasheet. Part 1 Type 2 cables are designed where a greater degree of mechanical protection is required namely outdoor / exposed or direct burial at suitable depth. Being BS 5308 Part 1 the insulation material is either PE or XLPE. The PVC sheathing material has an OI >30% and HCL <15% and the LSZH material is of type LTS3. Collectively and individually screened pairs are available within the range where further signal security is required.
Standards: BS/PAS 5308, BS EN 60228, BS 6234, BS 50363, IEC 60332-1, IEC 60332-3-24
BS5308 Instrumentation Cable Part 1 Type 1
Toggle
Eland Product Group: I
Application: BS5308 cables are designed to carry communication and control signals in a variety of installation types including those found in the petrochemical industry. The signals can be of analogue, data or voice type and from a variety of transducers such as pressure, proximity or microphone. Transducers. BS 5308 cables are designed to form part of an intrinsically safe system and the technical information required to determine their suitability for this application is contained within the datasheet. Part 1 Type 1 cables are generally designed for indoor use and in environments where mechanical protection is not required. Being BS 5308 Part 1 the insulation material is either PE or XLPE. The PVC sheathing material has an OI >30% and HCL <15% and the LSZH material is of type LTS3. Collectively and individually screened pairs are available within the range where further signal security is required.
Standards: BS/PAS 5308, BS EN 60228, BS 6234, BS 50363, IEC 60332-1, IEC 60332-3-24
318-Y Cable H05VV-F to BS6500
Toggle
Eland Product Group: A5Y and A6Y
Application: For use in household appliances such as washing machines, spin dryers and refrigerators. Generally unsuitable for outdoor use or industrial applications.
Standards:
0.5 - 2.5mm˛ to BS6500,
4.0mm˛ to BS7919
6.0mm˛ generally to BS7919
VDE28
CENELEC HD21.5
NSGAFOU Cable
Toggle
Eland Product Group: A5N
Application: Single core cable for use in switch cabinets, wiring of devices, trains and buses as well as in dry rooms.
Standards: DIN VDE 0250-602
Elandflex Cable
Toggle
Eland Product Group: A2F
Application: Highly flexible single core conductors with a great variety of industrial applications, such as cable harnesses, panel wiring and power generation.
Standards: IEC 60332-1
Multi-Core Data Cables to Def Stan 61/12 Part 5
Toggle
Eland Product Group: A2D
Application: These multicore flexible cables are designed for high density wiring between components and within instruments and electronic equipment. They are extensively used in aircraft, process control systems, computers, data processors, military vehicles and military equipment.
Standards: Generally to Def Stan 61-12 Part 5
Twinflex Battery Cable
Toggle
Eland Product Group: A1T
Application: For indoors and outdoors, in dry as well as wet location on motorised vehicles, or battery powered equipment such as fork lifts and field conveyors. Also in high quality booster cables.
Standards: Figure 8 configuration based on VDE0250
Multi-Core Data Cables to Def Stan 61/12 Part 4
Toggle
Eland Product Group: A2D
Application: These Multi-Core flexible cables are designed for high density wiring between components and within instruments and electronic equipment. They are extensively used in aircraft, process control systems, computers, data processors, military vehicles and military equipment.
Standards: Generally to Def. Stan 61-12 Part 4