Armoured Cable
Control Flexible Cable
Rubber Flexible Cable
PVC Flexible Cable
High Temperature Cable
Fixed Wiring Cable
LSZH Flexible Cable
BS5308 Instrumentation Cable
Belden Cable
Belden Alternative Cable
Fire Performance Cable
Coaxial Cable
Data Cable
Telephone Cable
Defence Standard Cable
Aluminium Conductors
Profibus and Profinet Cable
Welding Cable
Solar Cable
Signalling Cable
Power Cable
Earthing Cable
Telecom Cable
Points Heating Cable
Overhead Line Cable
Rolling Stock
Telephone, Data, and Coaxial
CW1128 Telephone Cable
Toggle
Eland Product Group: A8T
Application: Cables primarily designed for the interconnection of telephone equipment. In addition these cables may be used for interconnection of other communication and control equipment or low level signalling applications.
Standards: CW1128
Coaxial CT Cable
Toggle
Eland Product Group: A7E
Application: Ideal for professional TV and CCTV system installations including digital satellite, terrestrial and Cable TV.
Which CT Cable is right for me?
Read more about Coaxial Cable.
Conductor: Solid plain copper
Coaxial BT3002/RA7000 Eq. Cable
Toggle
Eland Product Group: A7E
Application: Manufactured to BT specifications and used for interconnecting of data or telecoms equipment.
Read more about Coaxial Cable.
Conductor: Solid plain copper
Coaxial RG/URM/Composite Cable
Toggle
Eland Product Group: A7E
Application: High quality RG Type Coaxial cables, 50 or 75 Ohm is suitable for many applications, including low power video, video signal, and broadband signals. Many types are available in Duct Grade, LSF or LSZH versions.
Conductor:
RG6: CCS (Copper Clad Steel)
RG11: TCW (Tinned Copper Wire)
RG58: TCW (Tinned Copper Wire)
RG59: CCS (Copper Clad Steel)
RG179: TCW (Tinned Copper Wire)
RG213 PVC: PCW (Plain Copper Wire)
RG213 LSZH: PCW (Plain Copper Wire)
URM67: PCW (Plain Copper Wire)
URM70: PCW (Plain Copper Wire)
75 Ohm Coax + 1Pair: PCW (Plain Copper Wire)
+ TCW (Tinned Copper Wire)
75 Ohm Coax + 1Pair: PCW (Plain Copper Wire)
+ TCW (Tinned Copper Wire)
Cat 5E FTP PVC Cable
Toggle
Eland Product Group: A8N
Application: A multipair (usually 4 pair) high performance cable that consists of twisted pair conductors, used mainly for data transmission. Category 5E is recommended for all new and existing installations, supports a frequency range of up to 100MHz and is designed for transmission speeds of up to 1 gigabit per second (Gigabit Ethernet).
Read more about LAN Cables and the differences between these types of data cables.
Standards: ISO/IEC11801, TIA/EIA 568B
Cat 5E PE FTP GSWB LSZH Cable
Toggle
Eland Product Group: A8N
Application: Also known as Armoured Cat 5E Cable, this cable is used for horizontal wiring in a local area network (LAN) in areas requiring mechanical protection.
Read more about LAN Cables and the differences between these types of data cables.
Standards: ISO/IEC11801, TIA/EIA 568B
Cat 5E UTP Moulded and Booted Patch Leads
Toggle
Eland Product Group: A8P
Application:
Each patch lead is manufactured, tested and independently verified to ISO 11801 Cat 5E and EIA/TIA standards.
Each patch lead has 8 colour-coded cores that are made from stranded 24 AWG and twisted together to form 4 pairs with different lay lengths. The soft PVC outer sheath together with the stranded copper cores, gives a very flexible cable. Because the patch leads are available in different colours, different departments or applications can be identified.
The patch leads are fitted with a strain relief boot for applications that may need a small amount of stress relief applied to each cable—or for applications where continuous patching is necessary.
These items come individually bagged.
Conductor: Stranded bare copper
Cat 5E UTP PE External Cable
Toggle
Eland Product Group: A8N
Application: A multipair (usually 4 pair) high
performance cable that consists of
twisted pair conductors, used mainly
for data transmission. Category
5 E is recommended for all new and existing
installations, supports a frequency
range of up to 100MHz and is
designed for transmission speeds of
up to 1 gigabit per second (Gigabit
Ethernet). Cat 5E UTP is suitable for
outdoor use.
Read more about LAN Cables and the differences between these types of data cables.
Standards: ISO/IEC 11801, TIA/EIA 568B
Cat 5E UTP PVC Cable
Toggle
Eland Product Group: A8N
Application: A multipair (usually 4 pair) high performance cable that consists of twisted pair conductors, used mainly for data transmission. Category 5E is recommended for all new and existing installations, supports a frequency range of up to 100MHz and is designed for transmission speeds of up to 1 gigabit per second (Gigabit Ethernet).
Read more about LAN Cables and the differences between these types of data cables.
Standards: ISO/IEC11801, TIA/EIA 568B
Cat 6 LSZH Cable
Toggle
Eland Product Group: A8N
Application: A multipair (usually 4 pair) high
performance cable that consists of
twisted pair conductors, used mainly
for data transmission.
Category 6 is recommended for
all new and existing installations, supports a
frequency range of up to 250MHz
and is designed for transmission
speeds of up to 1 gigabit per
second (Gigabit Ethernet).
Read more about LAN Cables and the differences between these types of data cables.
Standards: ISO/IEC11801, TIA/EIA 568B
CAT 6 PE Cable
Toggle
Eland Product Group: A8N
Application: A multipair (usually 4 pair) high performance cable that consists of twisted pair conductors, used mainly for data transmission. Category 6 is recommended for all new installations, supports a frequency range of up to 250MHz and is designed for transmission speeds of up to 1 gigabit per second(Gigabit Ethernet).
Standards:
ISO/IEC11801
TIA/EIA 568B
EN 50173
YD/T1019-2001
Cat 5E UTP LSZH Cable
Toggle
Eland Product Group: A8N
Application: A multipair (usually 4 pair) high performance cable that consists of twisted pair conductors, used mainly for data transmission. Category 5 E is recommended for all new and existing installations, supports a frequency range of up to 100MHz and is designed for transmission speeds of up to 1 gigabit per second (Gigabit Ethernet).
Read more about LAN Cables and the differences between these types of data cables.
Standards: ISO/IEC11801, TIA/EIA 568B
Cat 5E FTP PE Cable
Toggle
Eland Product Group: A8N
Application: A multipair (usually 4 pair) high performance cable that consists of twisted pair conductors, used mainly for data transmission. Category 5E is recommended for all new installations, supports a frequency range of up to 100MHz and is designed for transmission speeds of up to 1 gigabit per second (Gigabit Ethernet).
Standards:
ISO/IEC 11801
TIA/EIA 568B
YD/T1019-2001
Cat 5E 25 Pair UTP Duct Grade Cable
Toggle
Eland Product Group: A8N
Application: This 25 pair high performance backbone cable is suitable for outdoor use (in a duct). It can be installed in 100Base-T, Gigabit Ethernet, 155 Mbps ATM, TP-PMD Audio, Multimedia and Telephone networks.
Read more about LAN Cables and the differences between these types of data cables.
Conductor: Solid bare copper
Cat 5E 25 Pair UTP LSZH Cable
Toggle
Eland Product Group: A8N
Application: This 25 pair LSZH backbone cable is suitable for 100Base-T, Gigabit Ethernet, 155 Mbps ATM, TP-PMD Audio, Multimedia and Telephone networks.
Read more about LAN Cables and the differences between these types of data cables.
Conductor: Class 1 solid plain copper
CW1308B Internal/External Telecom Cable
Toggle
Eland Product Group: A8T
Application: Cables primarily designed for the interconnection of telephone equipment both internally and externally. In addition these cables may be used for the interconnection of other communication and control equipment or low level signalling applications. The cable specification is further enhanced by the use of a Low Smoke Zero Halogen outer sheath.
Standards: CW1308, IEC 60754-1
CW1308 Internal Telecom Cable
Toggle
Eland Product Group: A8T
Application: Cables primarily designed for the interconnection of telephone equipment which is installed indoors. In addition these cables may be used for the interconnection of other communication and control equipment or low level signalling applications.
Standards: CW1308
CW1128/1198 Direct Burial Telephone Cable
Toggle
Eland Product Group: A8T
Application: External armoured cable primarily designed for the interconnection of telephone equipment. Suitable for direct burial. UV and moisture resistant. In addition these cables may be used for interconnection of other communication and control equipment or low level signaling applications
Standards: CW1128/1198
CT100 Pre-terminated
Toggle
Eland Product Group: A7E
Application: CT100 Foam Filled, 25m coil. Pre-terminated with connectors and supplied coiled in a bag. Suitable for set top box installs.
Conductor: Solid plain copper