Twinflex Battery Cable
- Eland Product Group:
- A1T
- Application:
- For indoors and outdoors, in dry as well as wet location on motorised vehicles, or battery powered equipment such as fork lifts and field conveyors. Also in high quality booster cables.
- Standards:
- Figure 8 configuration based on VDE0250
- Conductor:
- Extra flexible class 6 copper conductors to BS6360
- Insulation:
- Red and Black TPE
- Sheath:
- Transparent PVC (Type TM2 to VDE0207)
- Colour:
- Red and Black
- Voltage Rating:
- 300/500V
- Temperature Rating:
- -25 to +70°C
- Minimum Bending Radius:
- 6 x overall diameter
Specifications Data
Download detailed Twinflex Battery Cable specifications as a PDF file (171kb)
| No. of Cores x Nominal Cross Sectional Area # x mm² | No. and Nominal Diameter of Strands # x mm | Nominal Thickness of Insulationmm | Nominal Thickness of Sheathmm | Nominal Overall Diametermm | Nominal Weightkg/Km |
|---|---|---|---|---|---|
| 2 x 2.5 | 133 x 0.15 | 0.8 | 0.8 | 4.4 x 10.8 | 90 |
| 2 x 4.0 | 217 x 0.15 | 0.8 | 0.8 | 4.7 x 11.4 | 120 |
| 2 x 6.0 | 189 x 0.20 | 0.8 | 0.8 | 5.3 x 12.6 | 160 |
| 2 x 10.0 | 315 x 0.20 | 1.0 | 0.8 | 6.0 x 13.8 | 270 |
| 2 x 16.0 | 494 x 0.20 | 1.0 | 0.8 | 6.7 x 15.2 | 400 |
| 2 x 25.0 | 779 x 0.20 | 1.2 | 1.0 | 8.1 x 18.0 | 605 |
| 2 x 35.0 | 1083 x 0.20 | 1.2 | 1.0 | 9.1 x 20.0 | 780 |
| 2 x 50.0 | 1554 x 0.20 | 1.4 | 1.0 | 14.6 x 30.6 | 1150 |
| 2 x 70.0 | 2220 x 0.20 | 1.4 | 1.0 | 16.4 x 34.4 | 1580 |
| 2 x 95.0 | 2950 x 0.20 | 1.6 | 1.0 | 18.4 x 38.6 | 2080 |