SWA Cable - BS5467 Steel Wire Armoured PVC
Eland Product Group: A9S
Application: SWA BS 5467 Cable - power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting.
Standards: BS5467, IEC 60502, BSEN (IEC) 60332-1-2
Conductor: Class 2 stranded plain copper conductor to BS EN 60228:2005 (previously BS6360)
Insulation: XLPE (Cross-Linked Polyethylene)
Bedding: PVC (Polyvinyl Chloride)
Armouring:
Single Core: AWA (Aluminium Wire Armour)
Multi Core: SWA (Steel Wire Armour)
Sheath: PVC (Polyvinyl Chloride)
Sheath Colour: Black (Carbon loaded for UV stability)
Voltage Rating: 600/1000V
Temperature Rating: 0ºC to +90ºC
Minimum Bending Radius:
1.5mm² - 16mm²
6 x overall diameter
25mm² and above:
8 x overall diameter
Core Identification:
1 Core: Brown
2 Cores: Brown, Blue
3 Cores: Brown, Black, Grey
4 Cores: Blue, Brown, Black, Grey
5 Cores: Green/Yellow, Blue, Brown, Black, Grey
Alternative core identification: White Cores with Black numbers
For more information please consult a member of the Sales Team.
SWA Cable - BS5467 Steel Wire Armoured PVC
| Eland Part Number # x mm |
No. of Cores x Nominal Cross Sectional Area | Nominal Overall Diameter |
|---|---|---|
| A9AWA150 | 1 x 50.0 | 17.5 |
| A9AWA170 | 1 x 70.0 | 20.2 |
| A9AWA195 | 1 x 95.0 | 22.3 |
| A9AWA1120 | 1 x 120.0 | 24.2 |
| A9AWA1150 | 1 x 150.0 | 27.4 |
| A9AWA1185 | 1 x 185.0 | 30.0 |
| A9AWA1240 | 1 x 240.0 | 32.8 |
| A9AWA1300 | 1 x 300.0 | 35.6 |
| A9AWA1400 | 1 x 400.0 | 40.4 |
| A9AWA1500 | 1 x 500.0 | 44.2 |
| A9AWA1630 | 1 x 630.0 | 48.8 |
| A9AWA1800 | 1 x 800.0 | 55.4 |
| A9AWA1800 | 1 x 1000.0 | 60.6 |
| A9SWA2015 | 2 x 1.5 | 12.1 |
| A9SWA2025 | 2 x 2.5 | 13.6 |
| A9SWA2040 | 2 x 4.0 | 14.7 |
| A9SWA2060 | 2 x 6.0 | 15.9 |
| A9SWA210 | 2 x 10.0 | 18.0 |
| A9SWA216 | 2 x 16.0 | 20.4 |
| A9SWA225 | 2 x 25.0 | 20.4 |
| A9SWA235 | 2 x 35.0 | 23.3 |
| A9SWA250 | 2 x 50.0 | 25.8 |
| A9SWA270 | 2 x 70.0 | 29.0 |
| A9SWA295 | 2 x 95.0 | 33.1 |
| A9SWA2120 | 2 x 120.0 | 36.1 |
| A9SWA2150 | 2 x 150.0 | 39.3 |
| A9SWA3015 | 3 x 1.5 | 12.6 |
| A9SWA3025 | 3 x 2.5 | 14.1 |
| A9SWA3040 | 3 x 4.0 | 15.3 |
| A9SWA3060 | 3 x 6.0 | 16.6 |
| A9SWA310 | 3 x 10.0 | 19.5 |
| A9SWA316 | 3 x 16.0 | 21.6 |
| A9SWA325 | 3 x 25.0 | 25.5 |
| A9SWA335 | 3 x 35.0 | 28.0 |
| A9SWA350 | 3 x 50.0 | 28.5 |
| A9SWA370 | 3 x 70.0 | 32.2 |
| A9SWA395 | 3 x 95.0 | 37.0 |
| A9SWA3120 | 3 x 120.0 | 40.4 |
| A9SWA3150 | 3 x 150.0 | 45.5 |
| A9SWA3185 | 3 x 185.0 | 49.8 |
| A9SWA3240 | 3 x 240.0 | 55.1 |
| A9SWA3300 | 3 x 300.0 | 60.2 |
| A9SWA3400 | 3 x 400.0 | 66.6 |
| A9SWA4015 | 4 x 1.5 | 13.5 |
| A9SWA4025 | 4 x 2.5 | 15.0 |
| A9SWA4040 | 4 x 4.0 | 16.4 |
| A9SWA4060 | 4 x 6.0 | 18.7 |
| A9SWA410 | 4 x 10.0 | 21.1 |
| A9SWA416 | 4 x 16.0 | 22.9 |
| A9SWA425 | 4 x 25.0 | 27.6 |
| A9SWA435 | 4 x 35.0 | 30.4 |
| A9SWA450 | 4 x 50.0 | 32.0 |
| A9SWA470 | 4 x 70.0 | 37.7 |
| A9SWA495 | 4 x 95.0 | 41.7 |
| A9SWA4120 | 4 x 120.0 | 47.1 |
| A9SWA4150 | 4 x 150.0 | 51.4 |
| A9SWA4185 | 4 x 185.0 | 56.6 |
| A9SWA4240 | 4 x 240.0 | 63.0 |
| A9SWA4300 | 4 x 300.0 | 68.8 |
| A9SWA4400 | 4 x 400.0 | 78.1 |
| A9SWA5015 | 5 x 1.5 | 14.3 |
| A9SWA5025 | 5 x 2.5 | 16.3 |
| A9SWA5040 | 5 x 4.0 | 17.8 |
| A9SWA5060 | 5 x 6.0 | 20.0 |
| A9SWA510 | 5 x 10.0 | 22.9 |
| A9SWA516 | 5 x 16.0 | 26.6 |
| A9SWA525 | 5 x 25.0 | 31.5 |
| A9SWA535 | 5 x 35.0 | 34.8 |
| A9SWA550 | 5 x 50.0 | 40.4 |
| A9SWA0715 | 7 x 1.5 | 15.2 |
| A9SWA7025 | 7 x 2.5 | 17.1 |
| A9SWA1215 | 12 x 1.5 | 19.4 |
| A9SWA12025 | 12 x 2.5 | 22.4 |
| A9SWA1915 | 19 x 1.5 | 22.2 |
| A9SWA1925 | 19 x 2.5 | 26.6 |
| A9SWA2715 | 27 x 1.5 | 26.7 |
| A9SWA2725 | 27 x 2.5 | 30.7 |
| A9SWA3715 | 37 x 1.5 | 29.0 |
| A9SWA3725 | 37 x 2.5 | 33.8 |