SWA Cable - BS5467 Steel Wire Armoured PVC
Toggle
Eland Product Group: A9S
Application: SWA Cable - power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting.
Standards: BS5467, IEC 60502
SWA Cable - BS6724 Steel Wire Armoured LSZH
Toggle
Eland Product Group: A9L
Application: SWA Cable - power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment.
Standards: BS6724, IEC 60754-1
6491B Conduit Wiring Cable H07Z-R to BS7211
Toggle
Eland Product Group: A3Z
Application: Suitable for use in conduit and for fixed, protected installation. In particular for installation where fire, smoke emission and toxic fumes create a potential threat.
Standards: BS7211, BASEC approved*, BS EN/IEC 60228
6491X Cable H07V-R/H07V-U to BS6004
Toggle
Eland Product Group: A2X
Application: 6491X Cable H07V-R/H07V-U to BS6004 is suitable for power and lighting circuits and building wiring. The cable is intended for use in semi-flush exposed conduits and embedded conduits as well as in closed installation ducts, and is ideal for the internal wiring of appliances and apparatus.
Standards: BS6004, BASEC approved*
6181Y Double Insulated Wiring Cable to BS6004
Toggle
Eland Product Group: A1Y
Application: Fixed Installation in dry or damp areas for domestic and light industrial wiring.
Standards: BS6004
NYY-J Cable
Toggle
Eland Product Group: A9N
Application: Power and control cable for fixed installation. Can be used indoors, outdoors, underground, in concrete and in water.
Standards: IEC60502-1
Generally to VDE0276 and VDE0271.
RV-K Powerflex Cable
Toggle
Eland Product Group: A9R
Application: A flexible power and control cable designed for fixed applications. Manufactured with flexible conductors in order to facilitate installations with sinuous courses.
Standards: UNE 21123-2, IEC 502-1, EN 50265, IEC 60332-1
NHXMH-J Cable
Toggle
Eland Product Group: A9H
Application: These cables are intended for fixed installation in dry and moist rooms as well as in masonry and concrete, in and under plaster; not for underground installation. NHXMH-J/O are especially used in buildings with a high concentration of persons or valuable property, where improved fire characteristics are needed. This product conforms to 73/23/EW G directive (low voltage directive) CE.
Standards: VDE 0250 (part 214), VDE 0482 (part 266-2-4, test type C)
NYCY Power Cable
Toggle
Eland Product Group: A9N
Application: For use indoors, in cable ducts, outdoors and in earth for power plants, industrial plants, as well as in local power networks, if increased mechanical and electrical protection is required.
Standards: VDE0276 part 603, CENELEC HD603 S1, IEC 60502
7 cores and above to VDE0276 part 627, CENELEC HD627 S1, IEC 60502
NYCWY Power Cable
Toggle
Eland Product Group: A9N
Application: For use where increased electrical and mechanical protection is required, preferably for underground laying, especially in subscriber networks, power stations as well as control cables for the transmission of control impulses and test data.
Standards: VDE0276 part 603, CENELEC HD603 S1, IEC 60502
624-Y Twin and Earth
Toggle
Eland Product Group: A9A
Application: Domestic wiring cable. Can be installed in fixed installations in dry or damp premises clipped to surface, on trays or in free air where mechanical damage would not be an issue. Suitable for laying in conduit or trunking where mechanical protection is required.
Standards: BS 6004:2000 Table 8