NYCY Power Cable
- Eland Product Group:
- A9N
- Application:
- For use indoors, in cable ducts, outdoors and in earth for power plants, industrial plants, as well as in local power networks, if increased mechanical and electrical protection is required.
- Standards:
- VDE0276 part 603, CENELEC HD603 S1, IEC 60502
7 cores and above to VDE0276 part 627, CENELEC HD627 S1, IEC 60502 - Conductor:
- Class 1 solid plain copper to BS EN 60228:2005 (previously BS6360), VDE0295, IEC 60228, CENELEC HD383
- Insulation:
- PVC (Polyvinyl Chloride) to CENELEC HD603.1
- Bedding:
- PVC (Polyvinyl Chloride)
- Concentric Conductor:
- Copper wires and helical copper tape
- Sheath:
- PVC (Polyvinyl Chloride) to CENELEC HD603.1
- Sheath Colour:
- Black
- Voltage Rating:
- 600/1000V
- Temperature Rating:
Fixed: -40°C to +70°C
Flexing: -5°C to +50°C- Minimum Bending Radius:
Single Core: 15 x overall diameter
Multi-Core: 12 x overall diameter- Core Identification:
- Up to and including 5 cores: colour coded or number coded 7 cores and above: number coded
| No. of Cores x Nominal Cross Sectional Area# x mm² | Stranded Conductor Type | Nominal Overall Diametermm | Nominal Weightkg/Km |
|---|---|---|---|
| 1 x 10.0 | re / 10.0 | 11.0 | 280.0 |
| 1 x 16.0 | re / 16.0 | 12.0 | 440.0 |
| 2 x 1.5 | re / 1.5 | 13.0 | 205.0 |
| 2 x 2.5 | re / 2.5 | 13.5 | 270.0 |
| 2 x 4.0 | re / 4.0 | 15.5 | 360.0 |
| 2 x 6.0 | re / 6.0 | 17.0 | 435.0 |
| 2 x 10.0 | re / 10.0 | 19.5 | 590.0 |
| 2 x 16.0 | re / 16.0 | 20.5 | 820.0 |
| 3 x 1.5 | re / 1.5 | 13.5 | 225.0 |
| 3 x 2.5 | re / 2.5 | 14.5 | 290.0 |
| 3 x 4.0 | re / 4.0 | 16.5 | 400.0 |
| 3 x 6.0 | re / 6.0 | 17.5 | 510.0 |
| 3 x 10.0 | re / 10.0 | 20.0 | 850.0 |
| 3 x 16.0 | re / 16.0 | 23.0 | 1080.0 |
| 4 x 1.5 | re / 1.5 | 14.5 | 260.0 |
| 4 x 2.5 | re / 2.5 | 15.5 | 350.0 |
| 4 x 4.0 | re / 4.0 | 17.0 | 470.0 |
| 4 x 6.0 | re / 6.0 | 18.5 | 590.0 |
| 4 x 10.0 | re / 10.0 | 21.0 | 900.0 |
| 4 x 16.0 | re / 16.0 | 23.0 | 1250.0 |
| 5 x 1.5 | re / 1.5 | 15.0 | 330.0 |
| 5 x 2.5 | re / 2.5 | 16.0 | 400.0 |
| 5 x 4.0 | re / 4.0 | 19.0 | 560.0 |
| 5 x 6.0 | re / 6.0 | 21.0 | 710.0 |
| 5 x 10.0 | re / 10.0 | 23.0 | 1000.0 |
| 7 x 1.5 | re / 1.5 | 15.0 | 320.0 |
| 7 x 1.5 | re / 2.5 | 16.0 | 350.0 |
| 7 x 2.5 | re / 2.5 | 17.5 | 450.0 |
| 7 x 4.0 | re / 4.0 | 21.0 | 670.0 |
| 7 x 6.0 | re / 6.0 | 24.0 | 790.0 |
| 8 x 1.5 | re / 1.5 | 17.0 | 380.0 |
| 8 x 1.5 | re / 2.5 | 17.0 | 400.0 |
| 8 x 2.5 | re / 2.5 | 18.0 | 510.0 |
| 10 x 1.5 | re / 2.5 | 19.0 | 440.0 |
| 10 x 2.5 | re / 4.0 | 20.5 | 600.0 |
| 12 x 1.5 | re / 2.5 | 20.0 | 500.0 |
| 12 x 2.5 | re / 4.0 | 21.0 | 660.0 |
| 14 x 1.5 | re / 2.5 | 20.5 | 540.0 |
| 14 x 2.5 | re / 4.0 | 22.0 | 760.0 |
| 14 x 2.5 | re / 6.0 | 22.5 | 800.0 |
| 16 x 1.5 | re / 4.0 | 22.0 | 600.0 |
| 16 x 2.5 | re / 6.0 | 23.0 | 910.0 |
| 19 x 1.5 | re / 4.0 | 23.0 | 690.0 |
| 19 x 2.5 | re / 6.0 | 23.5 | 950.0 |
| 21 x 1.5 | re / 6.0 | 24.0 | 810.0 |
| 21 x 2.5 | re / 10.0 | 26.0 | 1100.0 |
| 24 x 1.5 | re / 6.0 | 26.0 | 860.0 |
| 24 x 2.5 | re / 10.0 | 28.0 | 1300.0 |
| 30 x 1.5 | re / 6.0 | 27.0 | 1230.0 |
| 30 x 2.5 | re / 10.0 | 30.0 | 1610.0 |
| 40 x 1.5 | re / 10.0 | 30.0 | 1590.0 |
| 40 x 2.5 | re / 10.0 | 35.0 | 2100.0 |
| 52 x 1.5 | re / 10.0 | 32.0 | 1820.0 |
| 52 x 2.5 | re / 10.0 | 38.0 | 2500.0 |
| 61 x 1.5 | re / 10.0 | 33.0 | 2000.0 |
| 61 x 2.5 | re / 10.0 | 40.0 | 2850.0 |