
Armoured Cable
Control Flexible Cable
Rubber Flexible Cable
PVC Flexible Cable
High Temperature Cable
Fixed Wiring Cable
LSZH Flexible Cable
BS5308 Instrumentation Cable
Belden Cable
Belden Alternative Cable
Fire Performance Cable
Coaxial Cable
Data Cable
Telephone Cable
Defence Standard Cable
Aluminium Conductors
Profibus and Profinet Cable
Welding Cable
Solar Cable
Signalling Cable
Power Cable
Earthing Cable
Telecom Cable
Points Heating Cable
Overhead Line Cable
Rolling Stock
Fixed Wiring Cable
SWA Cable - BS5467 Steel Wire Armoured PVC
Eland Product Group: A9S
Application: SWA Cable - power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting.
Standards: BS5467, IEC 60502
Conductor: Class 2 stranded plain copper conductor to BS EN 60228:2005 (previously BS6360)
Insulation: XLPE (Cross-Linked Polyethylene)
Bedding: PVC (Polyvinyl Chloride)
Armouring:
Single Core: AWA (Aluminium Wire Armour)
Multi Core: SWA (Steel Wire Armour)
Sheath: PVC (Polyvinyl Chloride)
Sheath Colour: Black
Voltage Rating: 600/1000V
Temperature Rating: 0°C to +90°C
Minimum Bending Radius:
1.5mm² - 16mm²:
6 x overall diameter
25mm² and above:
8 x overall diameter
Core Identification:
1 Core: Brown
2 Cores: Brown, Blue
3 Cores: Brown, Black, Grey
4 Cores: Blue, Brown, Black, Grey;
5 Cores: Green/Yellow,
Blue, Brown, Black, Grey
Alternative core identification:
White Cores with Black numbers
For more information please consult a member of the Sales Team.
SWA Cable - BS5467 Steel Wire Armoured PVC
| Eland Part Number |
No. of Cores x Nominal Cross Sectional Area # x mm2 |
Nominal Overall Diameter mm |
|---|---|---|
| A9AWA150 | 1 x 50.0 | 17.5 |
| A9AWA170 | 1 x 70.0 | 20.2 |
| A9AWA195 | 1 x 95.0 | 22.3 |
| A9AWA1120 | 1 x 120.0 | 24.2 |
| A9AWA1150 | 1 x 150.0 | 27.4 |
| A9AWA1185 | 1 x 185.0 | 30.0 |
| A9AWA1240 | 1 x 240.0 | 32.8 |
| A9AWA1300 | 1 x 300.0 | 35.6 |
| A9AWA1400 | 1 x 400.0 | 40.4 |
| A9AWA1500 | 1 x 500.0 | 44.2 |
| A9AWA1630 | 1 x 630.0 | 48.8 |
| A9AWA1800 | 1 x 800.0 | 55.4 |
| A9AWA1800 | 1 x 1000.0 | 60.6 |
| A9SWA2015 | 2 x 1.5 | 12.1 |
| A9SWA2025 | 2 x 2.5 | 13.6 |
| A9SWA2040 | 2 x 4.0 | 14.7 |
| A9SWA2060 | 2 x 6.0 | 15.9 |
| A9SWA210 | 2 x 10.0 | 18.0 |
| A9SWA216 | 2 x 16.0 | 20.4 |
| A9SWA225 | 2 x 25.0 | 20.4 |
| A9SWA235 | 2 x 35.0 | 23.3 |
| A9SWA250 | 2 x 50.0 | 25.8 |
| A9SWA270 | 2 x 70.0 | 29.0 |
| A9SWA295 | 2 x 95.0 | 33.1 |
| A9SWA2120 | 2 x 120.0 | 36.1 |
| A9SWA2150 | 2 x 150.0 | 39.3 |
| A9SWA3015 | 3 x 1.5 | 12.6 |
| A9SWA3025 | 3 x 2.5 | 14.1 |
| A9SWA3040 | 3 x 4.0 | 15.3 |
| A9SWA3060 | 3 x 6.0 | 16.6 |
| A9SWA310 | 3 x 10.0 | 19.5 |
| A9SWA316 | 3 x 16.0 | 21.6 |
| A9SWA325 | 3 x 25.0 | 25.5 |
| A9SWA335 | 3 x 35.0 | 28.0 |
| A9SWA350 | 3 x 50.0 | 28.5 |
| A9SWA370 | 3 x 70.0 | 32.2 |
| A9SWA395 | 3 x 95.0 | 37.0 |
| A9SWA3120 | 3 x 120.0 | 40.4 |
| A9SWA3150 | 3 x 150.0 | 45.5 |
| A9SWA3185 | 3 x 185.0 | 49.8 |
| A9SWA3240 | 3 x 240.0 | 55.1 |
| A9SWA3300 | 3 x 300.0 | 60.2 |
| A9SWA3400 | 3 x 400.0 | 66.6 |
| A9SWA4015 | 4 x 1.5 | 13.5 |
| A9SWA4025 | 4 x 2.5 | 15.0 |
| A9SWA4040 | 4 x 4.0 | 16.4 |
| A9SWA4060 | 4 x 6.0 | 18.7 |
| A9SWA410 | 4 x 10.0 | 21.1 |
| A9SWA416 | 4 x 16.0 | 22.9 |
| A9SWA425 | 4 x 25.0 | 27.6 |
| A9SWA435 | 4 x 35.0 | 30.4 |
| A9SWA450 | 4 x 50.0 | 32.0 |
| A9SWA470 | 4 x 70.0 | 37.7 |
| A9SWA495 | 4 x 95.0 | 41.7 |
| A9SWA4120 | 4 x 120.0 | 47.1 |
| A9SWA4150 | 4 x 150.0 | 51.4 |
| A9SWA4185 | 4 x 185.0 | 56.6 |
| A9SWA4240 | 4 x 240.0 | 63.0 |
| A9SWA4300 | 4 x 300.0 | 68.8 |
| A9SWA4400 | 4 x 400.0 | 78.1 |
| A9SWA5015 | 5 x 1.5 | 14.3 |
| A9SWA5025 | 5 x 2.5 | 16.3 |
| A9SWA5040 | 5 x 4.0 | 17.8 |
| A9SWA5060 | 5 x 6.0 | 20.0 |
| A9SWA510 | 5 x 10.0 | 22.9 |
| A9SWA516 | 5 x 16.0 | 26.6 |
| A9SWA525 | 5 x 25.0 | 31.5 |
| A9SWA535 | 5 x 35.0 | 34.8 |
| A9SWA550 | 5 x 50.0 | 40.4 |
| A9SWA0715 | 7 x 1.5 | 15.2 |
| A9SWA7025 | 7 x 2.5 | 17.1 |
| A9SWA1215 | 12 x 1.5 | 19.4 |
| A9SWA12025 | 12 x 2.5 | 22.4 |
| A9SWA1915 | 19 x 1.5 | 22.2 |
| A9SWA1925 | 19 x 2.5 | 26.6 |
| A9SWA2715 | 27 x 1.5 | 26.7 |
| A9SWA2725 | 27 x 2.5 | 30.7 |
| A9SWA3715 | 37 x 1.5 | 29.0 |
| A9SWA3725 | 37 x 2.5 | 33.8 |



