BS5308 Instrumentation Cable

BS5308 Instrumentation Cable Part 1 Type 1

Restriction of the use of Hazardous SubstancesBritish Standards InstituteInternational Electrotechnical Commission

Eland Product Group: A3I

Application: BS5308 cables are used to carry voice and data services, they also serve as the interconnection between electrical equipment and instruments, particularly in and around process plants, where transducer generated signals are transmitted through to panels, controllers and other devices.

Standards: BS5308 Part 1, BS EN/IEC 60228

Conductor: Class 1 solid, class 2 stranded or class 5 flexible plain copper to BS EN 60228:2005 (previously BS6360)

Pairing: Two insulated conductors uniformly twisted together with a lay not exceeding 100mm

Insulation: PE (Polyethylene) to BS6234 or XLPE (Cross Linked Polyethylene) to BS5308 or LSZH (Low Smoke Zero Halogen)

Filler Core: Unspecified material

Drain Wire: Tinned copper

Screen:
Individually Screened Pairs:
Aluminium/polyester tape is applied to each pair, metallic side down and in continuous contact with a 0.5mm² tinned copper drain wire

Collectively Screened Cables:
Aluminium/polyester tape is applied over the laid up pairs metallic side down and in continuous contact with a 0.5mm² tinned copper drain wire

Sheath: PVC (Polyvinyl Chloride) to BS7655 or LSZH (Low Smoke Zero Halogen)

Sheath Colour: Blue or Black

Voltage Rating: 300/500V

Temperature Rating:
Fixed: -30°C to + 70°C
Flexing: -5°C to + 50°C

Pair Identification - Individually Pair Screened: See Pair Identification table on page 2 of the data-sheet pdf

Note: These cables are not suitable for direct connection to the public mains supply

For more information please consult a member of the Sales Team.

BS5308 Instrumentation Cable Part 1 Type 1

Eland Part Number
No. of Pairs x Nominal Cross Sectional Area
# x mm2
Nominal Overall Diameter
mm
A3I0105CP1T1* 1 x 0.50 7.0
A3I0175CP1T1* 1 x 0.75** 7.3
A3I0110CP1T1* 1 x 1.00 7.4
A3I0115CP1T1* 1 x 1.50 8.3
A3I0205CP1T1* 2 x 0.50 7.9
A3I0275CP1T1* 2 x 0.75** 8.3
A3I0210CP1T1* 2 x 1.00 8.4
A3I0215CP1T1* 2 x 1.50 9.7
A3I0505CP1T1* 5 x 0.50 13.1
A3I0575CP1T1* 5 x 0.75** 14.3
A3I0510CP1T1* 5 x 1.00 14.2
A3I0515CP1T1* 5 x 1.50 16.4
A3I1005CP1T1* 10 x 0.50 17.2
A3I1075CP1T1* 10 x 0.75** 18.7
A3I1010CP1T1* 10 x 1.00 18.4
A3I1015CP1T1* 10 x 1.50 21.6
A3I2005CP1T1* 20 x 0.50 22.3
A3I2075CP1T1* 20 x 0.75** 24.5
A3I2010CP1T1* 20 x 1.00 24.4
A3I2015CP1T1* 20 x 1.50 28.5
A3I3005CP1T1* 30 x 0.50 26.9
A3I3075CP1T1* 30 x 0.75** 29.5
A3I3010CP1T1* 30 x 1.00 29.0
A3I3015CP1T1* 30 x 1.50 34.3
A3I5005CP1T1* 50 x 0.50 33.9
A3I5075CP1T1* 50 x 0.75** 37.4
A3I5010CP1T1* 50 x 1.00 37.3
A3I5015CP1T1* 50 x 1.50 43.6
A3I0205IP1T1* 2 x 0.50 12.0
A3I0275IP1T1* 2 x 0.75** 12.8
A3I0210IP1T1* 2 x 1.00 12.8
A3I0215IP1T1* 2 x 1.50 14.7
A3I0505IP1T1* 5 x 0.50 15.2
A3I0575IP1T1* 5 x 0.75** 16.3
A3I0510IP1T1* 5 x 1.00 16.2
A3I0515IP1T1* 5 x 1.50 18.8
A3I1005IP1T1* 10 x 0.50 21.1
A3I1075IP1T1* 10 x 0.75** 22.6
A3I1010IP1T1* 10 x 1.00 22.6
A3I1015IP1T1* 10 x 1.50 26.5
A3I2005IP1T1* 20 x 0.50 27.3
A3I2075IP1T1* 20 x 0.75** 29.8
A3I2010IP1T1* 20 x 1.00 29.8
A3I2015IP1T1* 20 x 1.50 34.4
A3I3005IP1T1* 30 x 0.50 32.3
A3I3075IP1T1* 30 x 0.75** 35.9
A3I3010IP1T1* 30 x 1.00 35.4
A3I3015IP1T1* 30 x 1.50 41.0
A3I5005IP1T1* 50 x 0.50 41.7
A3I5075IP1T1* 50 x 0.75** 45.0
A3I5010IP1T1* 50 x 1.00 44.9
A3I5015IP1T1* 50 x 1.50 52.2

Cable Gland A2

Cable Gland A2