
Armoured Cable
Control Flexible Cable
Rubber Flexible Cable
PVC Flexible Cable
High Temperature Cable
Fixed Wiring Cable
LSZH Flexible Cable
BS5308 Instrumentation Cable
Belden Cable
Belden Alternative Cable
Fire Performance Cable
Coaxial Cable
Data Cable
Telephone Cable
Defence Standard Cable
Aluminium Conductors
Profibus and Profinet Cable
Welding Cable
Solar Cable
Signalling Cable
Power Cable
Earthing Cable
Telecom Cable
Points Heating Cable
Overhead Line Cable
Rolling Stock
PVC Flexible Cable
Tri-rated Cable (H07V2-K) to BS6231
Eland Product Group: A2T
Application: Tri-rated Cable panel wiring is a high temperature, flame retardant cable designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers. Tri-rated Cable is sometimes referred to as BS6231 Cable, H07V2-K or Panel Wire.
Standards:
BS6231 Type CK
UL Subj.758
CSA C22.2 No. 210
HD 21.7 S2*
Ul Style Number:
1015: 0.50mm² - 6.00mm²
1015(1028): 10.00mm²
1015(1283): 16.00mm² - 35.00mm²
1015(1284): 50.00mm² - 240.00mm²
Conductor: Class 5 flexible plain copper conductors to BS EN 60228:2005 (previously BS6360)
Insulation: PVC (Polyvinyl Chloride)
Insulation Colour: Black, Red, Blue, Light Blue, Dark Blue, Yellow, Green/Yellow, Grey, Brown, Orange, White, Violet, Green, Pink
Voltage Rating:
BS6231: 600/1000V
UL, CSA: 600V
HD21.7 S2: 300V / 500V, 450V / 750V
Temperature Rating:
BS6231: 90°C (105°C for 15,000 hours)
UL, CSA: 105°C
Minimum Bending Radius: 6 x overall diameter
Note:
HD 21.7 S2 covers conductor sizes up to 35mm”, cables above this size are generally to the specification.
Where it is intended to connect cables contained within this datasheet to equipment or accessories confirmation should be obtained to ensure that they are capable of withstanding the operating temperature of the cable.
In the event of the equipment or accessories having a lower temperature range the cables should be de-rated accordingly as per BS 7671 Regulation 512.1.5.
For more information please consult a member of the Sales Team.
Tri-rated Cable (H07V2-K) to BS6231
| Eland Part Number |
No. of Cores x Nominal Cross Sectional Area # x mm² |
Nominal Overall Diameter mm |
|---|---|---|
| A2T*0005 | 1 x 0.50 | 2.50 |
| A2T*00075** | 1 x 0.75 | 2.70 |
| A2T*0010 | 1 x 1.00 | 2.95 |
| A2T*0015 | 1 x 1.50 | 3.20 |
| A2T*0025 | 1 x 2.50 | 3.65 |
| A2T*0040 | 1 x 4.00 | 4.20 |
| A2T*0060 | 1 x 6.00 | 4.70 |
| A2T*010 | 1 x 10.00 | 6.50 |
| A2T*016L | 1 x 16.00 | 8.00 |
| A2T*025D | 1 x 25.00 | 9.40 |
| A2T*035 | 1 x 35.00 | 10.60 |
| A2T*050 | 1 x 50.00 | 12.90 |
| A2T*070 | 1 x 70.00 | 14.60 |
| A2T*095 | 1 x 95.00 | 16.10 |
| A2T*120 | 1 x 120.00 | 17.90 |
| A2T*150 | 1 x 150.00 | 20.20 |
| A2T*185 | 1 x 185.00 | 22.85 |
| A2T*240 | 1 x 240.00 | 24.40 |



