Twinflex Battery Cable
- Eland Product Group:
- A1T
- Application:
- For indoors and outdoors, in dry as well as wet location on motorised vehicles, or battery powered equipment such as fork lifts and field conveyors. Also in high quality booster cables.
- Standards:
- Figure 8 configuration based on VDE0250
- Conductor:
- Class 6 extra flexible plain copper conductors to BS EN 60228:2005 (previously BS6360)
- Insulation:
- TPE (Thermoplastic Elastomer)
- Sheath:
- PVC (Polyvinyl Chloride) Type TM2 to VDE0207
- Insulation Colour:
- Red and Black
- Sheath Colour:
- Transparent
- Voltage Rating:
- 300/500V
- Temperature Rating:
- -25°C to +70°C
- Minimum Bending Radius:
- 6 x overall diameter
RoHS Compliant
| No. of Cores x Nominal Cross Sectional Area # x mm² | No. and Nominal Diameter of Strands # x mm | Nominal Thickness of Insulationmm | Nominal Thickness of Sheathmm | Nominal Overall Diametermm | Nominal Weightkg/Km |
|---|---|---|---|---|---|
| 2 x 2.5 | 133 x 0.15 | 0.8 | 0.8 | 4.4 x 10.8 | 90 |
| 2 x 4.0 | 217 x 0.15 | 0.8 | 0.8 | 4.7 x 11.4 | 120 |
| 2 x 6.0 | 189 x 0.20 | 0.8 | 0.8 | 5.3 x 12.6 | 160 |
| 2 x 10.0 | 315 x 0.20 | 1.0 | 0.8 | 6.0 x 13.8 | 270 |
| 2 x 16.0 | 494 x 0.20 | 1.0 | 0.8 | 6.7 x 15.2 | 400 |
| 2 x 25.0 | 779 x 0.20 | 1.2 | 1.0 | 8.1 x 18.0 | 605 |
| 2 x 35.0 | 1083 x 0.20 | 1.2 | 1.0 | 9.1 x 20.0 | 780 |
| 2 x 50.0 | 1554 x 0.20 | 1.4 | 1.0 | 14.6 x 30.6 | 1150 |
| 2 x 70.0 | 2220 x 0.20 | 1.4 | 1.0 | 16.4 x 34.4 | 1580 |
| 2 x 95.0 | 2950 x 0.20 | 1.6 | 1.0 | 18.4 x 38.6 | 2080 |