Telecom Accessories

2, 5, 10 Way Connection Boxes

2, 5, 10 Way Connection Boxes

Restriction of the use of Hazardous Substances

Eland Product Group: ATA

Application: 2 Way
The ATA2WAY Connection Box is a wall-mounted 20 pair voice connection box manufactured in mid grey flame retardant PVC (Polyvinyl Chloride). It is primarily used for connection of CW1308 voice cabling. It can have up to 2 x 10 pair IDC disconnection strips and designation strips.

Features and Benefits:

  • Cables access is via lid knockout features
  • Internal cable management features incorporating integral jumper rings and a 10 way earth bar
  • Two captive screws ensure the lid is kept firmly in place.
  • Mark up field to underside of lid for labelling and identification

Application: 5 Way
The ATA5WAY Connection Box is a wall-mounted 50 pair voice connection box manufactured in mid grey flame retardant PVC (Polyvinyl Chloride). It is primarily used for connection of CW1308 voice cabling. It can have up to 5 x 10 pair IDC disconnection strips and designation strips.

Features and Benefits:

  • Cables access is via side panel tear-out features.
  • Internal cable management via 4 off 37B jumper rings
  • The earth bar assembly provides a common earthing point
  • Side and end panels can be removed to allow side-by-side mounting
  • Captive quarter turn locking posts ensure that the lid can be easily removed and locked.

Application: 10 Way
The ATA10WAY Connection Box is a wall-mounted 100 pair voice connection box manufactured in mid grey flame retardant PVC (Polyvinyl Chloride). It is primarily used for connection of CW1308 voice cabling. It can have up to 10 x 10 pair IDC disconnection strips and designation strips.

Features and Benefits:

  • Cables access is via side panel tear out features
  • Internal cable management via 4 off 37B jumper rings
  • The earth bar assembly provides a common earthing point
  • Side and end panels can be removed to allow side-by-side mounting
  • Captive quarter turn locking posts ensure that the lid can be easily removed and locked

For more information please consult a member of the Sales Team.

2, 5, 10 Way Connection Boxes

Eland Part Number
Description
ATA2WAY 2 Way Connection Box
ATA5WAY 5 Way Connection Box
ATA10WAY 10 Way Connection Box

CW1308B Internal/External Telecom Cable

CW1308B Internal/External Telecom Cable

CW1128 Telephone Cable

CW1128 Telephone Cable

CW1308 Internal Telecom Cable

CW1308 Internal Telecom Cable

CW1128/1198 Direct Burial Telephone Cable

CW1128/1198 Direct Burial Telephone Cable