11kV XLPE LSZH Cable BS7835
Eland Product Group: A9M
Application: Power cables for power networks, underground, outdoors and in cable ducting. In particular for installation where fire, smoke emission and toxic fumes create a potential threat.
Standards: BS7835, IEC 60754-1
Conductor: Class 2 stranded plain copper conductor to BS EN 60228:2005 (previously BS6360)
Conductor screen: Semi-conducting material
Insulation: XLPE (Cross-Linked Polyethylene) Type GP8 to BS7655
Insulation Screen: Semi-conducting material
Metallic Screen: Individual and overall copper tape screen to BS6622
Filler: PETP (Polyethylene Terephthalate) fibres
Separator: Binding tape
Bedding: LSZH (Low Smoke Zero Halogen)
Armouring:
Single Core: Aluminium Wire Armoured (AWA)
MultiCore: Steel Wire Armoured (SWA)
Sheath: LSZH (Low Smoke Zero Halogen)
Colour: Red or Black
Voltage Rating: 6350/11000V
Temperature Rating: 0°C to +90°C
Combustion Characteristics:
Oxygen index: 35
Temperature index: 280°C
HCL emission: 0.5% in accordance
with BS EN 50267-2-1
Low smoke classification based on 3 metre cube test
Completed cables comply with the requirements of fire test BS4066-3 Category 3
Minimum Bending Radius:
Single Core: 15 x overall diameter
Three Core: 12 x overall diameter
(Single Core 12 x overall diameter and 3 core
10 x overall diameter where bands are positioned adjacent to joint or terminations provided that
the bending is carefully controlled by the use
of a former)
For more information please consult a member of the Sales Team.
11kV XLPE LSZH Cable BS7835
| Eland Part Number |
No. of Cores x Nominal Cross Sectional Area # x mm² |
Nominal Overall Diameter mm |
|---|---|---|
| A9M11KV01050L* | 1 x 50 | 28.50 |
| A9M11KV01070L* | 1 x 70 | 30.00 |
| A9M11KV01095L* | 1 x 95 | 31.70 |
| A9M11KV01120L* | 1 x 120 | 33.90 |
| A9M11KV01150L* | 1 x 150 | 35.70 |
| A9M11KV01185L* | 1 x 185 | 37.50 |
| A9M11KV01240L* | 1 x 240 | 40.00 |
| A9M11KV01300L* | 1 x 300 | 43.00 |
| A9M11KV01400L* | 1 x 400 | 45.80 |
| A9M11KV01500L* | 1 x 500 | 50.50 |
| A9M11KV01630L* | 1 x 630 | 54.80 |
| A9M11KV01800L* | 1 x 800 | 59.20 |
| A9M11KV011000L* | 1 x 1000 | 64.30 |
| A9M11KV03025L* | 3 x 25 | 48.80 |
| A9M11KV03035L* | 3 x 35 | 51.60 |
| A9M11KV03050L* | 3 x 50 | 54.60 |
| A9M11KV03070L* | 3 x 70 | 58.50 |
| A9M11KV03095L* | 3 x 95 | 62.60 |
| A9M11KV03120L* | 3 x 120 | 66.60 |
| A9M11KV03150L* | 3 x 150 | 69.80 |
| A9M11KV03185L* | 3 x 185 | 74.10 |
| A9M11KV03240L* | 3 x 240 | 81.20 |
| A9M11KV03300L* | 3 x 300 | 87.00 |