SWA Cable - BS5467 Steel Wire Armoured PVCSWA Cable - BS5467 Steel Wire Armoured PVC Toggle

Eland Product Group: A9S

Application: SWA Cable - power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting.

Standards: BS5467, IEC 60502

Full Product Specification

SWA Cable - BS6724 Steel Wire Armoured LSZHSWA Cable - BS6724 Steel Wire Armoured LSZH Toggle

Eland Product Group: A9L

Application: SWA Cable - power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment.

Standards: BS6724, IEC 60754-1

Full Product Specification

6491B Conduit Wiring Cable H07Z-R to BS72116491B Conduit Wiring Cable H07Z-R to BS7211 Toggle

Eland Product Group: A3Z

Application: Suitable for use in conduit and for fixed, protected installation. In particular for installation where fire, smoke emission and toxic fumes create a potential threat.

Standards: BS7211, BASEC approved*, BS EN/IEC 60228

Full Product Specification

6491X Cable H07V-R/H07V-U to BS60046491X Cable H07V-R/H07V-U to BS6004 Toggle

Eland Product Group: A2X

Application: 6491X Cable H07V-R/H07V-U to BS6004 is suitable for power and lighting circuits and building wiring. The cable is intended for use in semi-flush exposed conduits and embedded conduits as well as in closed installation ducts, and is ideal for the internal wiring of appliances and apparatus.

Standards: BS6004, BASEC approved*

Full Product Specification

6181Y Double Insulated Wiring Cable to BS60046181Y Double Insulated Wiring Cable to BS6004 Toggle

Eland Product Group: A1Y

Application: Fixed Installation in dry or damp areas for domestic and light industrial wiring.

Standards: BS6004

Full Product Specification

NYY-J CableNYY-J Cable Toggle

Eland Product Group: A9N

Application: Power and control cable for fixed installation. Can be used indoors, outdoors, underground, in concrete and in water.

Standards: IEC60502-1
Generally to VDE0276 and VDE0271.

Full Product Specification

RV-K Powerflex CableRV-K Powerflex Cable Toggle

Eland Product Group: A9R

Application: A flexible power and control cable designed for fixed applications. Manufactured with flexible conductors in order to facilitate installations with sinuous courses.

Standards: UNE 21123-2, 60502-1, EN 50265, IEC 60332-1

Full Product Specification

NHXMH-J CableNHXMH-J Cable Toggle

Eland Product Group: A9H

Application: These cables are intended for fixed installation in dry and moist rooms as well as in masonry and concrete, in and under plaster; not for underground installation. NHXMH-J/O are especially used in buildings with a high concentration of persons or valuable property, where improved fire characteristics are needed. This product conforms to 73/23/EW G directive (low voltage directive) CE.

Standards: VDE 0250 (part 214), VDE 0482 (part 266-2-4, test type C)

Full Product Specification

NYCY Power CableNYCY Power Cable Toggle

Eland Product Group: A9N

Application: For use indoors, in cable ducts, outdoors and in earth for power plants, industrial plants, as well as in local power networks, if increased mechanical and electrical protection is required.

Standards: VDE0276 part 603, CENELEC HD603 S1, IEC 60502
7 cores and above to VDE0276 part 627, CENELEC HD627 S1, IEC 60502

Full Product Specification

NYCWY Power CableNYCWY Power Cable Toggle

Eland Product Group: A9N

Application: For use where increased electrical and mechanical protection is required, preferably for underground laying, especially in subscriber networks, power stations as well as control cables for the transmission of control impulses and test data.

Standards: VDE0276 part 603, CENELEC HD603 S1, IEC 60502

Full Product Specification