CY LSZH Control Flexible Cable to BS6500CY LSZH Control Flexible Cable to BS6500 Toggle

Eland Product Group: A5B

Application: For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use when temporarily moved, and in conditions of medium mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.

Standards: Generally to BS6500, IEC 60754-1

Full Product Specification

YY LSZH Control Flexible Cable to BS6500YY LSZH Control Flexible Cable to BS6500 Toggle

Eland Product Group: A5L

Application: For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.

Standards: Generally to BS6500, VDE0250, IEC 60332-3, IEC 60754-1

Full Product Specification

Cat 5E UTP LSZH CableCat 5E UTP LSZH Cable Toggle

Eland Product Group: A8N

Application: A multipair (usually 4 pair) high performance cable that consists of twisted pair conductors, used mainly for data transmission. Category 5 E is recommended for all new and existing installations, supports a frequency range of up to 100MHz and is designed for transmission speeds of up to 1 gigabit per second (Gigabit Ethernet).

Read more about LAN Cables and the differences between these types of data cables.

Standards: ISO/IEC11801, TIA/EIA 568B

Full Product Specification

Cat 6 LSZH CableCat 6 LSZH Cable Toggle

Eland Product Group: A8N

Application: A multipair (usually 4 pair) high performance cable that consists of twisted pair conductors, used mainly for data transmission. Category 6 is recommended for all new and existing installations, supports a frequency range of up to 250MHz and is designed for transmission speeds of up to 1 gigabit per second (Gigabit Ethernet).

Read more about LAN Cables and the differences between these types of data cables.

Standards: ISO/IEC11801, TIA/EIA 568B

Full Product Specification

Cat 5E PE FTP GSWB LSZH CableCat 5E PE FTP GSWB LSZH Cable Toggle

Eland Product Group: A8N

Application: Also known as Armoured Cat 5E Cable, this cable is used for horizontal wiring in a local area network (LAN) in areas requiring mechanical protection.

Read more about LAN Cables and the differences between these types of data cables.

Standards: ISO/IEC11801, TIA/EIA 568B

Full Product Specification

RZ1-K LSZH CableRZ1-K LSZH Cable Toggle

Eland Product Group: A9R

Application: For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. A flexible power and control cable designed for fixed applications. Manufactured with flexible conductors in order to facilitate installations with sinuous courses.

Standards: UNE 21123-2, 60502-1, EN 50265, IEC 60332-1

Full Product Specification

2491B / 6701B Flexible Cable H05Z-K/H07Z-K to BS72112491B / 6701B Flexible Cable H05Z-K/H07Z-K to BS7211 Toggle

Eland Product Group: A2Z

Application: In pipes or ducts and internal wiring of appliances with maximum operating temperatures of 90°C, and generally in areas (such as public and government buildings) where smoke and toxic fumes may cause a threat to life and equipment. The cables produce no corrosive gasses when burnt which is particularly important where electronic equipment is installed.

Standards: BS7211, CENELEC HD22.9, IEC 60332-3-24

Full Product Specification

318-B LSZH Cable H05Z1Z1-F318-B LSZH Cable H05Z1Z1-F Toggle

Eland Product Group: A5Z

Application: Used as an indoor general wiring cable primarily for installations in public areas. Examples include use on pendant lighting drops or as a general supply lead within hospital or airport projects. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment.

Standards: IEC 60092-353

Full Product Specification

6381 LSZH Cable6381 LSZH Cable Toggle

Eland Product Group: A1F LS

Application: Suitable for D.C. power supplies on Telecom equipment and power applications where flexibility is required. The cables produce no corrosive gases when burnt which is important where electronic equipment is installed.

Conductor: Class 5 flexible annealed plain copper conductors to BS EN 60228:2005 (previously BS6360)

Full Product Specification

H07ZZ-F CableH07ZZ-F Cable Toggle

Eland Product Group: A6G and A5G

Application: For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Examples of use include supplying mobile power units, UPS installations, stage lighting and audio visual equipment. This cable will withstand medium mechanical stresses and is suitable for both installation indoors and outdoors.

Standards:
CENELEC HD22-13
NFC 032-131
IEC 60332-3

Full Product Specification