CY Control Flexible Cable to BS6500
Toggle
Eland Product Group: A5C
Application: Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use when temporarily moved, and in conditions of medium mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
Standards: Generally to BS6500
CY LSZH Control Flexible Cable to BS6500
Toggle
Eland Product Group: A5B
Application: For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use when temporarily moved, and in conditions of medium mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
Standards: Generally to BS6500, IEC 60754-1
YY Control Flexible Cable to BS6500
Toggle
Eland Product Group: A5Y
Application: Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
Standards: Generally to BS6500, VDE0250
YY LSZH Control Flexible Cable to BS6500
Toggle
Eland Product Group: A5L
Application: For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
Standards: Generally to BS6500, VDE0250, IEC 60332-3, IEC 60754-1
SY Control Flexible Cable to BS6500
Toggle
Eland Product Group: A5J
Application: Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
The braided screen offers the best possible protection against mechanical damage and offers a level of Electro-magnetic shielding. The galvanised coating helps protect against corrosion.
Standards: Generally to BS6500, VDE0250
218-Y Flexible Cable H03VV-F to BS6500
Toggle
Eland Product Group: A3Y
Application: Light duty cable for use in domestic premises, kitchens and offices. For use with light portable appliances such as radios, table lamps and office machines.
Standards: BS6500, CENELEC HD21.5, VDE 281
2192Y Flexible Cable H03VVH2-F to BS6500
Toggle
Eland Product Group: A3Y
Application: Used as an indoor general wiring cable primarily for installations in public areas. Examples include use on pendant lighting drops or as a general supply lead.
Standards: BS6500
309-Y Flexible Cable H05V2V2-F to BS6500
Toggle
Eland Product Group: A5Y
Application: Supply leads for use as 318-Y but particularly for use in high temperature zones, for internal wiring or supply cords to electrical apparatus. Not suitable for outdoor use.
Standards: BS6500, BS7919 above 4.0mm˛
318-Y Cable H05VV-F to BS6500
Toggle
Eland Product Group: A5Y and A6Y
Application: For use in household appliances such as washing machines, spin dryers and refrigerators. Generally unsuitable for outdoor use or industrial applications.
Standards:
0.5 - 2.5mm˛ to BS6500,
4.0mm˛ to BS7919
6.0mm˛ generally to BS7919
VDE28
CENELEC HD21.5
318-TQ Cable H05BN4-F
Toggle
Eland Product Group: A5Q
Application: Flexible cords suitable for use in domestic premises, kitchens and offices. Also suitable for use in hot situations such as immersion heaters. Good resistance to oil and grease.
Standards: BS6500, VDE 0282