
Armoured Cable
Control Flexible Cable
Rubber Flexible Cable
PVC Flexible Cable
High Temperature Cable
Fixed Wiring Cable
LSZH Flexible Cable
BS5308 Instrumentation Cable
Belden Cable
Belden Alternative Cable
Fire Performance Cable
Coaxial Cable
Data Cable
Telephone Cable
Defence Standard Cable
Aluminium Conductors
Profibus and Profinet Cable
Welding Cable
Solar Cable
Signalling Cable
Power Cable
Earthing Cable
Telecom Cable
Points Heating Cable
Overhead Line Cable
Rolling Stock
Tri-rated Cable (H07V2-K) to BS6231
Toggle
Eland Product Group: A2T
Application: Tri-rated Cable panel wiring is a high temperature, flame retardant cable designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers. Tri-rated Cable is sometimes referred to as BS6231 Cable, H07V2-K or Panel Wire.
Standards:
BS6231 Type CK
UL Subj.758
CSA c.22.2 No. 127 (only applicable for
sizes up to 120mm²)
HD 21.7 S2*
6381Y Cable to BS6004
Toggle
Eland Product Group: A1F
Application: Suitable for AC and DC power supplies on Telecom equipment and power applications where flexibility is required.
Standards: Generally to BS6004, BS EN/IEC 60228
218-Y Flexible Cable H03VV-F to BS6500
Toggle
Eland Product Group: A3Y
Application: Light duty cable for use in domestic premises, kitchens and offices. For use with light portable appliances such as radios, table lamps and office machines.
Standards: BS6500, CENELEC HD21.5, VDE 281
2192Y Flexible Cable H03VVH2-F to BS6500
Toggle
Eland Product Group: A3Y
Application: Used as an indoor general wiring cable primarily for installations in public areas. Examples include use on pendant lighting drops or as a general supply lead.
Standards: BS6500
2491X Flexible Cable H05V-K H07V-K to BS6004
Toggle
Eland Product Group: A5V
Application: Designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers.
Standards: BS6004, CENELEC HD21.3
309-Y Flexible Cable H05V2V2-F to BS6500
Toggle
Eland Product Group: A5Y
Application: Supply leads for use as 318-Y but particularly for use in high temperature zones, for internal wiring or supply cords to electrical apparatus. Not suitable for outdoor use.
Standards: BS6500, BS7919 above 4.0mm²
318-Y Cable H05VV-F to BS6500
Toggle
Eland Product Group: A5Y and A6Y
Application: For use in household appliances such as washing machines, spin dryers and refrigerators. Generally unsuitable for outdoor use or industrial applications.
Standards:
0.5 - 2.5mm² to BS6500,
4.0mm² to BS7919
6.0mm² generally to BS7919
VDE28
CENELEC HD21.5
Alarm Cable - TCCA
Toggle
Eland Product Group: A3A
Application: Flexible alarm cable used for the wiring of burglar alarms and other low voltage circuits.
Conductor: TCCA (Tinned Copper Clad Aluminium)
Arctic Grade Cable
Toggle
Eland Product Group: A5A
Application: Designed to withstand severe external temperatures remaining flexible at temperatures as low as -40°C. Arctic Grade PVC mains cords manufactured to BS7919 will remain flexible at temperatures down to minus 40°C making them particularly suitable for outdoor applications and for use where flexibility is required at sub zero temperatures. At normal temperatures the cable is very limp and flexible, offering some of the characteristics usually found in elastomeric cables.
Standards: BS7919 Table 44, VDE281
Curly Flex PVC Cable
Toggle
Eland Product Group: A2C
Application: For use in domestic appliances, ceiling to display or cash desk equipment and indoor lighting features.
Conductor: Class 5 flexible plain copper conductors to BS EN 60228:2005 (previously BS6360), VDE0295
Elandflex Cable
Toggle
Eland Product Group: A2F
Application: Highly flexible single core conductors with a great variety of industrial applications, such as cable harnesses, panel wiring and power generation.
Standards: IEC 60332-1
Elevator Cable / Flatform Cable H05VVH6-F
Toggle
Eland Product Group: A1TR
Application: Elevator/Flatform Cable is a flat traveling PVC Cable used in conveyor and hoist equipment. This cable is suitable for internal and panoramic elevator applications with a freely suspended length up to 45 metres.
Standards: BS EN 50214
Festoon Cable - Internal
Toggle
Twinflex Battery Cable
Toggle
Eland Product Group: A1T
Application: For indoors and outdoors, in dry as well as wet location on motorised vehicles, or battery powered equipment such as fork lifts and field conveyors. Also in high quality booster cables.
Standards: Figure 8 configuration based on VDE0250
Speaker Cable
Toggle
Eland Product Group: A4S
Application: For audio installations.
Standards: EN50289, UL1581, UL758
