Armoured Cable
Control Flexible Cable
Rubber Flexible Cable
PVC Flexible Cable
High Temperature Cable
Fixed Wiring Cable
LSZH Flexible Cable
BS5308 Instrumentation Cable
Belden Cable
Belden Alternative Cable
Fire Performance Cable
Coaxial Cable
Data Cable
Telephone Cable
Defence Standard Cable
Aluminium Conductors
Profibus and Profinet Cable
Welding Cable
Solar Cable
Signalling Cable
Power Cable
Earthing Cable
Telecom Cable
Points Heating Cable
Overhead Line Cable
Rolling Stock
SWA Cable - BS5467 Steel Wire Armoured PVC
Toggle
Eland Product Group: A9S
Application: SWA Cable - power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting.
Standards: BS5467, IEC 60502
SWA Cable - BS6724 Steel Wire Armoured LSZH
Toggle
Eland Product Group: A9L
Application: SWA Cable - power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment.
Standards: BS6724, IEC 60754-1
Aluminium Power Cable
Toggle
Eland Product Group: A3T
Application: BR880 solid sector shaped conductors for trackside signalling power supplies.
Standards: BR880, BS5467, BS6346
MV Power Cable
Toggle
Eland Product Group: A9M
Application: Cable used to distribute three phase a.c. electrical power supplies at nominal system voltages of 33kV to traction substations on D.C. electrified lines.
Standards: NR/PS/ELP/00008 (formerly RT/E/PS/00008) BS6622, BS6234, BS7454, IEC 60502-2, IEC 60840
Trackfeeder Cable
Toggle
Eland Product Group: A3T
Application: Provides the 650/750 volt DC supply from Traction Substations and Track Paralleling Huts to conductor rails, negative cable connections and where appropriate, bonding
Standards: NR/PS/ELP/21101 (formerly RT/E/S/21101)
11kV XLPE PVC Cable
Toggle
Eland Product Group: A9M
Application: Power cables for power networks, underground, outdoors and in cable ducting.
Standards: BS6622, BS EN/IEC 60228
11kV XLPE LSZH Cable BS7835
Toggle
Eland Product Group: A9M
Application: Power cables for power networks, underground, outdoors and in cable ducting. In particular for installation where fire, smoke emission and toxic fumes create a potential threat.
Standards: BS7835, IEC 60754-1
33kV XLPE Cable
Toggle
Eland Product Group: A9M
Application: Power cables for power networks, underground, outdoors and in cable ducting.
Standards: BS6622
11kV XLPE MDPE Cable
Toggle
Eland Product Group: A9M
Application: Power cables for power networks, underground and in cable ducting.
Standards: BS6622