SWA Cable - BS6724 Steel Wire Armoured LSZH
Eland Product Group: A9L
Application: SWA Cable - power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment.
Standards: BS6724, IEC 60754-1
Conductor: Class 2 stranded plain annealed copper conductor to BS EN 60228:2005 (previously BS6360)
Insulation: XLPE (Cross-Linked Polyethylene)
Bedding: LSZH (Low Smoke Zero Halogen)
Armouring:
Single Core: AWA (Aluminium Wire Armour)
Multi Core: SWA (Steel Wire Armour)
Sheath: LSZH (Low Smoke Zero Haloge
Sheath Colour: Black
Voltage Rating: 600/1000V
Temperature Rating: 0°C to +90°C
Minimum Bending Radius:
1.5mm² - 16mm²:
6 x overall diameter
25mm² and above:
8 x overall diameter
Core Identification:
1 Core: Brown
2 Cores: Brown, Blue
3 Cores: Brown, Black, Grey
4 Cores: Blue, Brown, Black, Grey
5 Cores: Green/Yellow, Blue, Brown,
Black, Grey
Alternative core identification: White Cores with Black numbers
For more information please consult a member of the Sales Team.
SWA Cable - BS6724 Steel Wire Armoured LSZH
| No. of Cores x Cross Sectional Area # x mm² |
Nominal Overall Diameter mm |
Quantities |
Color |
description |
|---|---|---|---|---|
| 1 x 50.0 | 17.5 | metres | black | 1 x 50.0 |
| 1 x 70.0 | 20.2 | metres | black | 1 x 70.0 |
| 1 x 95.0 | 22.3 | metres | black | 1 x 95.0 |
| 1 x 120.0 | 24.2 | metres | black | 1 x 120.0 |
| 1 x 150.0 | 27.4 | metres | black | 1 x 150.0 |
| 1 x 185.0 | 30.0 | metres | black | 1 x 185.0 |
| 1 x 240.0 | 32.8 | metres | black | 1 x 240.0 |
| 1 x 300.0 | 35.6 | metres | black | 1 x 300.0 |
| 1 x 400.0 | 40.4 | metres | black | 1 x 400.0 |
| 1 x 500.0 | 44.2 | metres | black | 1 x 500.0 |
| 1 x 630.0 | 48.8 | metres | black | 1 x 630.0 |
| 1 x 800.0 | 55.4 | metres | black | 1 x 800.0 |
| 1 x 1000.0 | 60.6 | metres | black | 1 x 1000.0 |
| 2 x 1.5 | 12.1 | metres | black | 2 x 1.5 |
| 2 x 2.5 | 13.6 | metres | black | 2 x 2.5 |
| 2 x 4.0 | 14.7 | metres | black | 2 x 4.0 |
| 2 x 6.0 | 15.9 | metres | black | 2 x 6.0 |
| 2 x 10.0 | 18.0 | metres | black | 2 x 10.0 |
| 2 x 16.0 | 20.4 | metres | black | 2 x 16.0 |
| 2 x 25.0 | 20.4 | metres | black | 2 x 25.0 |
| 2 x 35.0 | 23.3 | metres | black | 2 x 35.0 |
| 2 x 50.0 | 25.8 | metres | black | 2 x 50.0 |
| 2 x 70.0 | 29.0 | metres | black | 2 x 70.0 |
| 2 x 95.0 | 33.1 | metres | black | 2 x 95.0 |
| 2 x 120.0 | 36.1 | metres | black | 2 x 120.0 |
| 2 x 150.0 | 39.3 | metres | black | 2 x 150.0 |
| 2 x 185.0 | 44.7 | metres | black | 2 x 185.0 |
| 2 x 240.0 | 49.0 | metres | black | 2 x 240.0 |
| 3 x 1.5 | 12.6 | metres | black | 3 x 1.5 |
| 3 x 2.5 | 14.1 | metres | black | 3 x 2.5 |
| 3 x 4.0 | 15.3 | metres | black | 3 x 4.0 |
| 3 x 6.0 | 16.6 | metres | black | 3 x 6.0 |
| 3 x 10.0 | 19.5 | metres | black | 3 x 10.0 |
| 3 x 16.0 | 21.6 | metres | black | 3 x 16.0 |
| 3 x 25.0 | 25.5 | metres | black | 3 x 25.0 |
| 3 x 35.0 | 28.0 | metres | black | 3 x 35.0 |
| 3 x 50.0 | 28.5 | metres | black | 3 x 50.0 |
| 3 x 70.0 | 32.2 | metres | black | 3 x 70.0 |
| 3 x 95.0 | 37.0 | metres | black | 3 x 95.0 |
| 3 x 120.0 | 40.4 | metres | black | 3 x 120.0 |
| 3 x 150.0 | 45.5 | metres | black | 3 x 150.0 |
| 3 x 185.0 | 49.8 | metres | black | 3 x 185.0 |
| 3 x 240.0 | 55.1 | metres | black | 3 x 240.0 |
| 3 x 300.0 | 60.2 | metres | black | 3 x 300.0 |
| 3 x 400.0 | 66.6 | metres | black | 3 x 400.0 |
| 4 x 1.5 | 13.5 | metres | black | 4 x 1.5 |
| 4 x 2.5 | 15.0 | metres | black | 4 x 2.5 |
| 4 x 4.0 | 16.4 | metres | black | 4 x 4.0 |
| 4 x 6.0 | 18.7 | metres | black | 4 x 6.0 |
| 4 x 10.0 | 21.1 | metres | black | 4 x 10.0 |
| 4 x 16.0 | 22.9 | metres | black | 4 x 16.0 |
| 4 x 25.0 | 27.6 | metres | black | 4 x 25.0 |
| 4 x 35.0 | 30.4 | metres | black | 4 x 35.0 |
| 4 x 50.0 | 32.0 | metres | black | 4 x 50.0 |
| 4 x 70.0 | 37.7 | metres | black | 4 x 70.0 |
| 4 x 95.0 | 41.7 | metres | black | 4 x 95.0 |
| 4 x 120.0 | 47.1 | metres | black | 4 x 120.0 |
| 4 x 150.0 | 51.4 | metres | black | 4 x 150.0 |
| 4 x 185.0 | 56.6 | metres | black | 4 x 185.0 |
| 4 x 240.0 | 63.0 | metres | black | 4 x 240.0 |
| 4 x 300.0 | 68.8 | metres | black | 4 x 300.0 |
| 4 x 400.0 | 78.1 | metres | black | 4 x 400.0 |
| 5 x 1.5 | 14.3 | metres | black | 5 x 1.5 |
| 5 x 2.5 | 16.3 | metres | black | 5 x 2.5 |
| 5 x 4.0 | 17.8 | metres | black | 5 x 4.0 |
| 5 x 6.0 | 20.0 | metres | black | 5 x 6.0 |
| 5 x 10.0 | 22.9 | metres | black | 5 x 10.0 |
| 5 x 16.0 | 26.6 | metres | black | 5 x 16.0 |
| 5 x 25.0 | 31.5 | metres | black | 5 x 25.0 |
| 5 x 35.0 | 34.8 | metres | black | 5 x 35.0 |
| 5 x 50.0 | 40.4 | metres | black | 5 x 50.0 |
| 5 x 70.0 | 46.3 | metres | black | 5 x 70.0 |
| 7 x 1.5 | 15.2 | metres | black | 7 x 1.5 |
| 7 x 2.5 | 17.1 | metres | black | 7 x 2.5 |
| 7 x 4.0 | 19.7 | metres | black | 7 x 4.0 |
| 12 x 1.5 | 19.4 | metres | black | 12 x 1.5 |
| 12 x 2.5 | 22.4 | metres | black | 12 x 2.5 |
| 12 x 4.0 | 25.7 | metres | black | 12 x 4.0 |
| 19 x 1.5 | 22.2 | metres | black | 19 x 1.5 |
| 19 x 2.5 | 26.6 | metres | black | 19 x 2.5 |
| 19 x 4.0 | 29.3 | metres | black | 19 x 4.0 |
| 27 x 1.5 | 26.7 | metres | black | 27 x 1.5 |
| 27 x 2.5 | 30.7 | metres | black | 27 x 2.5 |
| 27 x 4.0 | 34.4 | metres | black | 27 x 4.0 |
| 37 x 1.5 | 29.0 | metres | black | 37 x 1.5 |
| 37 x 2.5 | 33.8 | metres | black | 37 x 2.5 |
| 37 x 4.0 | 39.2 | metres | black | 37 x 4.0 |
| 48 x 1.5 | 32.7 | metres | black | 48 x 1.5 |
| 48 x 2.5 | 39.3 | metres | black | 48 x 2.5 |
| 48 x 4.0 | 44.1 | metres | black | 48 x 4.0 |