11kV XLPE LSZH Cable BS7835
- Eland Product Group:
- A9M
- Application:
- Power cables for power networks, underground, outdoors and in cable ducting. In particular for installation where fire, smoke emission and toxic fumes create a potential threat.
- Standards:
- BS7835
- Conductor:
- Class 2 stranded plain copper conductor to BS EN 60228:2005 (previously BS6360)
- Conductor Screen:
- Semi-conducting material
- Insulation:
- XLPE (Cross-Linked Polyethylene) Type GP8 to BS7655
- Insulation Screen:
- Semi-conducting material
- Metallic Screen:
- Individual and overall copper tape screen to BS6622
- Filler:
- PETP (Polyethylene Terephthalate) fibres
- Separator:
- Binding tape
- Bedding:
- LSZH (Low Smoke Zero Halogen)
- Armouring:
Single Core: Aluminium Wire Armoured (AWA)
MultiCore: Steel Wire Armoured (SWA)- Sheath:
- LSZH (Low Smoke Zero Halogen)
- Colour:
- Red or Black
- Voltage Rating:
- 6350/11000V
- Temperature Rating:
- 0°C to +90°C
- Combustion Characteristics:
Oxygen index: 35
Temperature index: 280°C
HCL emission: 0.5% in accordance with BS EN 50267-2-1
Low smoke classification based on 3 metre cube test
Completed cables comply with the requirements of fire test BS4066-3 Category 3- Minimum Bending Radius:
Single Core: 15 x overall diameter
Three Core: 12 x overall diameter
(Single Core 12 x overall diameter and 3 core 10 x overall diameter where bands are positioned adjacent to joint or terminations provided that the bending is carefully controlled by the use of a former)
| Cable Type | No. of Cores x Nominal Cross Sectional Area# x mm² | Nominal Diameter Under Armourmm | Nominal Diameter Over Armourmm | Nominal Diameter Overallmm | Nominal Weightkg/Km | Continuous Current Rating in Ground - TrefoilAmps | Continuous Current Rating in Ground - FlatAmps |
|---|---|---|---|---|---|---|---|
| Copper | 1 x 50 | 21.7 | 24.9 | 28.5 | 1200 | 220 | 230 |
| Copper | 1 x 70 | 23.0 | 26.2 | 30.0 | 1500 | 270 | 280 |
| Copper | 1 x 95 | 24.7 | 27.9 | 31.7 | 1600 | 320 | 335 |
| Copper | 1 x 120 | 26.7 | 29.9 | 33.9 | 2100 | 360 | 380 |
| Copper | 1 x 150 | 27.5 | 31.5 | 35.7 | 2500 | 410 | 430 |
| Copper | 1 x 185 | 29.3 | 33.3 | 37.5 | 2900 | 455 | 485 |
| Copper | 1 x 240 | 31.6 | 35.6 | 40.0 | 3600 | 520 | 560 |
| Copper | 1 x 300 | 34.6 | 38.6 | 43.0 | 4300 | 580 | 640 |
| Copper | 1 x 400 | 37.0 | 41.0 | 45.8 | 5200 | 650 | 730 |
| Copper | 1 x 500 | 40.5 | 45.5 | 50.5 | 6500 | 710 | 830 |
| Copper | 1 x 630 | 44.6 | 49.6 | 54.8 | 8000 | 760 | 940 |
| Copper | 1 x 800 | 48.8 | 53.8 | 59.2 | 9850 | 810 | 1060 |
| Copper | 1 x 1000 | 53.5 | 58.5 | 64.3 | 12100 | 860 | 1170 |
| Copper | 3 x 25 | 39.0 | 44.0 | 48.8 | 4300 | 140 | 140 |
| Copper | 3 x 35 | 41.6 | 46.6 | 51.6 | 4700 | 170 | 170 |
| Copper | 3 x 50 | 44.4 | 49.4 | 54.6 | 5300 | 210 | 210 |
| Copper | 3 x 70 | 48.1 | 53.1 | 58.5 | 6300 | 255 | 250 |
| Copper | 3 x 95 | 52.0 | 57.0 | 62.6 | 7300 | 300 | 300 |
| Copper | 3 x 120 | 55.6 | 60.6 | 66.6 | 8400 | 340 | 340 |
| Copper | 3 x 150 | 58.6 | 63.6 | 69.8 | 9600 | 380 | 380 |
| Copper | 3 x 185 | 62.7 | 67.7 | 74.1 | 11000 | 430 | 430 |
| Copper | 3 x 240 | 68.1 | 74.4 | 81.2 | 14000 | 490 | 500 |
| Copper | 3 x 300 | 73.5 | 79.8 | 87.0 | 16600 | 540 | 540 |
| Copper | 3 x 400 | 81.1 | 87.4 | 95.0 | 19500 | 590 | 600 |
| Aluminium | 1 x 50 | 30.9 | 34.9 | 39.3 | 1740 | 170 | 175 |
| Aluminium | 1 x 70 | 32.6 | 36.6 | 41.0 | 1850 | 210 | 215 |
| Aluminium | 1 x 95 | 34.3 | 38.3 | 42.9 | 2100 | 250 | 260 |
| Aluminium | 1 x 120 | 35.9 | 39.9 | 44.5 | 2250 | 280 | 295 |
| Aluminium | 1 x 150 | 37.5 | 42.5 | 47.3 | 2600 | 320 | 330 |
| Aluminium | 1 x 185 | 39.3 | 44.3 | 49.3 | 2850 | 360 | 375 |
| Aluminium | 1 x 240 | 41.7 | 46.7 | 51.7 | 3150 | 415 | 440 |
| Aluminium | 1 x 300 | 44.2 | 49.2 | 54.4 | 3600 | 475 | 495 |
| Aluminium | 1 x 400 | 47.3 | 52.3 | 57.7 | 4000 | 540 | 570 |
| Aluminium | 1 x 500 | 50.5 | 55.5 | 61.1 | 4500 | 610 | 650 |
| Aluminium | 1 x 630 | 54.2 | 59.2 | 65.0 | 5250 | 680 | 750 |
| Aluminium | 1 x 800 | 60.5 | 65.5 | 71.6 | 6150 | 770 | 860 |
| Aluminium | 1 x 1000 | 65.0 | 70.0 | 76.5 | 7200 | 859 | 960 |
| Aluminium | 3 x 50 | 65.1 | 71.4 | 78.2 | 8300 | 160 | 160 |
| Aluminium | 3 x 70 | 68.8 | 75.1 | 82.1 | 9050 | 195 | 195 |
| Aluminium | 3 x 95 | 72.6 | 78.9 | 86.1 | 9800 | 230 | 230 |
| Aluminium | 3 x 120 | 76.3 | 82.6 | 90.0 | 10600 | 265 | 265 |
| Aluminium | 3 x 150 | 79.3 | 85.6 | 93.2 | 11350 | 300 | 300 |
| Aluminium | 3 x 185 | 83.4 | 89.7 | 97.5 | 12250 | 335 | 335 |
| Aluminium | 3 x 240 | 88.8 | 95.1 | 103.3 | 13700 | 380 | 380 |
| Aluminium | 3 x 300 | 93.9 | 100.2 | 108.8 | 15500 | 435 | 435 |
| Aluminium | 3 x 400 | 100.8 | 107.1 | 116.1 | 16750 | 490 | 490 |
