Eland Cables has an extensive range of switchgear cables – such as Tri-rated Cable to BS6231 - used in switchgear systems. Switchgear cables are designed to isolate electrical equipment used in automation, process control and the building and construction industry.
These low voltage switch gear cables can help control power to buildings or machinery.
2491B / 6701B Flexible Cable H05Z-K/H07Z-K to BS7211
Toggle
Eland Product Group: A2Z
Application: In pipes or ducts and internal wiring of appliances with maximum operating temperatures of 90°C, and generally in areas (such as public and government buildings) where smoke and toxic fumes may cause a threat to life and equipment. The cables produce no corrosive gasses when burnt which is particularly important where electronic equipment is installed.
Standards: BS7211, CENELEC HD22.9, IEC 60332-3-24
Tri-rated Cable (H07V2-K) to BS6231
Toggle
Eland Product Group: A2T
Application: Tri-rated Cable panel wiring is a high temperature, flame retardant cable designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers. Tri-rated Cable is sometimes referred to as BS6231 Cable, H07V2-K or Panel Wire.
Standards:
BS6231 Type CK
UL Subj.758
CSA c.22.2 No. 127 (only applicable for
sizes up to 120mm²)
HD 21.7 S2*
CY Control Flexible Cable to BS6500
Toggle
Eland Product Group: A5C
Application: Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use when temporarily moved, and in conditions of medium mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
Standards: Generally to BS6500
YY Control Flexible Cable to BS6500
Toggle
Eland Product Group: A5Y
Application: Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
Standards: Generally to BS6500, VDE0250
SY Control Flexible Cable to BS6500
Toggle
Eland Product Group: A5J
Application: Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
The braided screen offers the best possible protection against mechanical damage and offers a level of Electro-magnetic shielding. The galvanised coating helps protect against corrosion.
Standards: Generally to BS6500, VDE0250
Coil End Lead Cable to BS6195
Toggle
Eland Product Group: A6K
Application: Coil leads are used mainly in electrical machinery and panel wiring. The HOFR sheath resists oil and varnish and the stranding is designed as a compromise between flexibility and positional stability. Also suitable as an alternative to tri-rated and bi-rated cable in certain applications.
Standards: BS6195 Type 4