CY Control Flexible Cable to BS6500
- Eland Product Group:
- A5C
- Application:
- Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use when temporarily moved, and in conditions of medium mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors. These cables with copper screening are ideally suitable for interference free data and signal transmission in measuring and control technology.
- Standards:
- Generally to BS6500, VDE0250
- Conductor:
- Class 5 flexible plain copper conductors to BS EN 60228:2005 (previously BS6360), VDE0295, IEC 60228
- Insulation:
- PVC (Polyvinyl Chloride) Type YI2
- Separator:
- PETP (Polyethylene Terephthalate)
- Screen:
CY: TCWB (Tinned Copper Wire Braid)
STCY: Aluminium Foil and Braid- Sheath:
- PVC (Polyvinyl Chloride) Type YI2
- Sheath Colour:
- Grey
- Voltage Rating:
- 300/500V
- Temperature Rating:
Fixed: -35°C to +70°C
Flexing: -15°C to +70°C- Minimum Bending Radius:
- 10 x overall diameter
- Core Identification:
- Black with White numbers. (3 cores and above to include Green/Yellow). Coloured cores available.
RoHS Compliant
Specifications Data
Download detailed CY Control Flexible Cable to BS6500 specifications as a PDF file (197kb)
| No. of Cores x Cross Sectional Area# x mm² | Nominal Overall Diametermm | Nominal Weightkg/Km | FCGCXT Gland |
|---|---|---|---|
| 2 x 0.50 | 5.4 | 45.0 | 20SS |
| 2 x 0.75 | 6.0 | 54.0 | 20SS |
| 2 x 0.75* | 5.4 | 47.4 | 20SS |
| 2 x 1.00 | 6.2 | 60.0 | 20SS |
| 2 x 1.00* | 5.9 | 57.4 | 20SS |
| 2 x 1.50 | 6.8 | 70.0 | 20SS |
| 2 x 1.50* | 6.6 | 74.4 | 20SS |
| 2 x 2.50 | 8.0 | 104.0 | 20S |
| 3 x 0.50 | 5.8 | 53.0 | 20SS |
| 3 x 0.75 | 6.3 | 65.0 | 20SS |
| 3 x 0.75* | 5.4 | 57.8 | 20SS |
| 3 x 1.00 | 6.5 | 73.0 | 20SS |
| 3 x 1.50 | 7.2 | 90.0 | 20S |
| 3 x 1.50* | 7.5 | 100.1 | 20S |
| 3 x 2.50 | 8.6 | 140.0 | 20S |
| 4 x 0.50 | 6.3 | 63.0 | 20SS |
| 4 x 0.75 | 6.8 | 77.0 | 20SS |
| 4 x 0.75* | 6.5 | 73.6 | 20SS |
| 4 x 1.00 | 7.0 | 89.0 | 20S |
| 4 x 1.50 | 7.8 | 108.0 | 20S |
| 4 x 1.50* | 8.2 | 123.3 | 20S |
| 4 x 2.50 | 9.4 | 173.0 | 20S |
| 4 x 4.00 | 11.1 | 236.0 | 20S |
| 4 x 6.00 | 12.8 | 339.0 | 20 |
| 4 x 10.00 | 16.1 | 502.0 | 25 |
| 4 x 16.00 | 19.2 | 771.0 | 25 |
| 4 x 25.00 | 20.2 | 1420.0 | 32 |
| 5 x 0.50 | 6.7 | 76.0 | 20SS |
| 5 x 0.75 | 7.3 | 91.0 | 20S |
| 5 x 1.00 | 7.6 | 105.0 | 20S |
| 5 x 1.50 | 8.4 | 125.0 | 20S |
| 5 x 2.50 | 10.0 | 206.0 | 20S |
| 5 x 4.00 | 12.1 | 288.0 | 20 |
| 5 x 6.00 | 14.2 | 416.0 | 25 |
| 6 x 0.50 | 7.2 | 87.0 | 20S |
| 6 x 0.75 | 7.8 | 102.0 | 20S |
| 6 x 1.00 | 8.2 | 110.0 | 20S |
| 7 x 0.50 | 7.3 | 107.0 | 20S |
| 7 x 0.75 | 7.8 | 115.0 | 20S |
| 7 x 1.00 | 8.4 | 139.0 | 20S |
| 7 x 1.50 | 9.3 | 160.0 | 20S |
| 7 x 2.50 | 10.8 | 267.0 | 20S |
| 8 x 0.50 | 7.7 | 109.0 | 20S |
| 8 x 0.75 | 8.3 | 137.0 | 20S |
| 8 x 1.00 | 9.0 | 157.0 | 20S |
| 12 x 0.50 | 9.2 | 140.0 | 20S |
| 12 x 0.75 | 10.1 | 177.0 | 20S |
| 12 x 1.00 | 10.4 | 207.0 | 20S |
| 12 x 1.50 | 11.8 | 279.0 | 20 |
| 12 x 2.50 | 14.6 | 432.0 | 25 |
| 18 x 0.50 | 10.2 | 179.0 | 20S |
| 18 x 0.75 | 11.6 | 250.0 | 20 |
| 18 x 1.00 | 12.4 | 295.0 | 20 |
| 18 x 1.50 | 14.0 | 350.0 | 25 |
| 25 x 0.50 | 13.3 | 256.0 | 25 |
| 25 x 0.75 | 13.9 | 326.0 | 25 |
| 25 x 1.00 | 14.9 | 384.0 | 25 |
| 25 x 1.50 | 16.9 | 530.0 | 25 |
| 34 x 0.75 | 15.6 | 406.0 | 25 |
| 34 x 1.00 | 16.6 | 530.0 | 25 |
| 34 x 1.50 | 18.9 | 720.0 | 25 |
| 42 x 1.50 | 20.1 | 820.0 | 32 |
| 50 x 0.75 | 19.0 | 576.0 | 32 |
| 50 x 1.00 | 19.6 | 1020.0 | 32 |