High Temperature Cables

Tri-rated Cable (H07V2-K) to BS6231

Restriction of the use of Hazardous SubstancesBritish Standards InstituteCenelecCSA InternationalHarmonized Commodity Description<br>and Coding SystemUnderwriters Laboratories

Eland Product Group: A2T

Application: Tri-rated Cable panel wiring is a high temperature, flame retardant cable designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers. Tri-rated Cable is sometimes referred to as BS6231 Cable, H07V2-K or Panel Wire.

Standards:
BS6231 Type CK
UL Subj.758
CSA c.22.2 No. 127 (only applicable for sizes up to 120mm²)
HD 21.7 S2*

Ul Style Number:
1015: 0.50mm² - 6.00mm²
1015(1028): 10.00mm²
1015(1283): 16.00mm² - 35.00mm²
1015(1284): 50.00mm² - 240.00mm²

Conductor: Class 5 flexible plain copper conductors to BS EN 60228:2005 (previously BS6360)

Insulation: PVC (Polyvinyl Chloride)

Insulation Colour: Black, Red, Blue, Light Blue, Dark Blue, Yellow, Green/Yellow, Grey, Brown, Orange, White, Violet, Green, Pink

Voltage Rating:
BS6231: 600/1000V
UL, CSA: 600V
HD21.7 S2: 300V / 500V, 450V / 750V

Temperature Rating:
BS6231: 90°C (105°C for 15,000 hours)
UL, CSA: 105°C

Minimum Bending Radius: 6 x overall diameter

Note: Cables above 120mm² in size are referred to as Bi-rated since the CSA standard applies only to sizes up to and including 120mm².

HD 21.7 S2 covers conductor sizes up to 35mm”, cables above this size are generally to the specification.

Where it is intended to connect cables contained within this datasheet to equipment or accessories confirmation should be obtained to ensure that they are capable of withstanding the operating temperature of the cable.

In the event of the equipment or accessories having a lower temperature range the cables should be de-rated accordingly as per BS 7671 Regulation 512.1.5.

For more information please consult a member of the Sales Team.

Tri-rated Cable (H07V2-K) to BS6231

Eland Part Number
No. of Cores
x Nominal
Cross Sectional
Area
# x mm²
Nominal
Overall
Diameter
mm
A2T*0005 1 x 0.50 2.50
A2T*00075** 1 x 0.75 2.70
A2T*0010 1 x 1.00 2.95
A2T*0015 1 x 1.50 3.20
A2T*0025 1 x 2.50 3.65
A2T*0040 1 x 4.00 4.20
A2T*0060 1 x 6.00 4.70
A2T*010 1 x 10.00 6.50
A2T*016L 1 x 16.00 8.00
A2T*025D 1 x 25.00 9.40
A2T*035 1 x 35.00 10.60
A2T*050 1 x 50.00 12.90
A2T*070 1 x 70.00 14.60
A2T*095 1 x 95.00 16.10
A2T*120 1 x 120.00 17.90
A2T*150 1 x 150.00 20.20
A2T*185 1 x 185.00 22.85
A2T*240 1 x 240.00 24.40

Copper Tube Terminals

Copper Tube Terminals

Uninsulated Cord End Terminals

Uninsulated Cord End Terminals

Heat Shrink

Heat Shrink