Armoured Cable
Control Flexible Cable
Rubber Flexible Cable
PVC Flexible Cable
High Temperature Cable
Fixed Wiring Cable
LSZH Flexible Cable
BS5308 Instrumentation Cable
Belden Cable
Belden Alternative Cable
Fire Performance Cable
Coaxial Cable
Data Cable
Telephone Cable
Defence Standard Cable
Aluminium Conductors
Profibus and Profinet Cable
Welding Cable
Solar Cable
Signalling Cable
Power Cable
Earthing Cable
Telecom Cable
Points Heating Cable
Overhead Line Cable
Rolling Stock
Your Industry
Airports
Eland’s high quality cables contribute to the smooth running and uninterrupted operation of the world’s busiest airports, where integrity of control systems, power networks and data infrastructure is mission critical. The company’s extensive portfolio ensures there is a solution to suit the diverse demands of every airport application – from the supply of power for airfield lighting, to high speed data cabling for air traffic control; solutions for the control of baggage handling systems, reliable operation of elevators, connections for emergency power and much more.
Whether you require low smoke, zero halogen, high temperature silicon or steel wired armoured specifications, solutions are available in a vast array of materials and voltages to meet the exacting demands of the aviation market.
The company offers installers peace of mind that the reliability and safety of their installation is ensured by using cables from the most respected and trusted suppliers. The broad array of power, lighting and data cables are subjected to rigorous physical testing by Eland to ensure they meet the highest levels of quality control.
Tri-rated Cable (H07V2-K) to BS6231
Toggle
Eland Product Group: A2T
Application: Tri-rated Cable panel wiring is a high temperature, flame retardant cable designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers. Tri-rated Cable is sometimes referred to as BS6231 Cable, H07V2-K or Panel Wire.
Standards:
BS6231 Type CK
UL Subj.758
CSA c.22.2 No. 127 (only applicable for
sizes up to 120mm˛)
HD 21.7 S2*
SWA Cable - BS5467 Steel Wire Armoured PVC
Toggle
Eland Product Group: A9S
Application: SWA Cable - power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting.
Standards: BS5467, IEC 60502
CY Control Flexible Cable to BS6500
Toggle
Eland Product Group: A5C
Application: Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use when temporarily moved, and in conditions of medium mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
Standards: Generally to BS6500
CY LSZH Control Flexible Cable to BS6500
Toggle
Eland Product Group: A5B
Application: For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use when temporarily moved, and in conditions of medium mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
Standards: Generally to BS6500, IEC 60754-1
YY Control Flexible Cable to BS6500
Toggle
Eland Product Group: A5Y
Application: Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
Standards: Generally to BS6500, VDE0250
YY LSZH Control Flexible Cable to BS6500
Toggle
Eland Product Group: A5L
Application: For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
Standards: Generally to BS6500, VDE0250, IEC 60332-3, IEC 60754-1
SY Control Flexible Cable to BS6500
Toggle
Eland Product Group: A5J
Application: Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
The braided screen offers the best possible protection against mechanical damage and offers a level of Electro-magnetic shielding. The galvanised coating helps protect against corrosion.
Standards: Generally to BS6500, VDE0250
H07RN-F Cable to BS7919
Toggle
Eland Product Group: A6G and A5G
Application: These cables are designed to provide high flexibility and have
the capacity to withstand weather,
oils/greases, mechanical and thermal stresses. Applications include handling equipment, mobile power supplies, worksites, stage and audio visual equipment, port areas and dams. Also for use in drainage and water treatment, cold environments and severe industrial environments.
Read more about H07RN-F Cables and their applications.
Standards: BS7919, CENELEC HD22.4 S4
SWA Cable - BS6724 Steel Wire Armoured LSZH
Toggle
Eland Product Group: A9L
Application: SWA Cable - power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment.
Standards: BS6724, IEC 60754-1
Cat 5E UTP PVC Cable
Toggle
Eland Product Group: A8N
Application: A multipair (usually 4 pair) high performance cable that consists of twisted pair conductors, used mainly for data transmission. Category 5E is recommended for all new and existing installations, supports a frequency range of up to 100MHz and is designed for transmission speeds of up to 1 gigabit per second (Gigabit Ethernet).
Read more about LAN Cables and the differences between these types of data cables.
Standards: ISO/IEC11801, TIA/EIA 568B
Unscreened Single Pair Cable (Belden Equivalent)
Toggle
Eland Product Group: A3B
Application: Unscreened Single Pair Cable (Belden Equivalent) is suitable for use in instrumentation, security, data, bus and audio applications where protection against electrical interference is not required.
Conductor: Stranded tinned copper
Alarm Cable - TCCA
Toggle
Eland Product Group: A3A
Application: Flexible alarm cable used for the wiring of burglar alarms and other low voltage circuits.
Conductor: TCCA (Tinned Copper Clad Aluminium)
Overall Screened Single Pair Cable (Belden Equivalent)
Toggle
Eland Product Group: A3B
Application: Overall Screened Single Pair Cable (Belden Equivalent) is suitable for use in instrumentation, data and audio applications where protection against electrical interference is required. Cables with polyethylene insulation show lower signal loss than those using PVC.
Conductor: Stranded tinned copper
Overall Screened Multi-Pair Cable (Belden Equivalent)
Toggle
Eland Product Group: A3B
Application: Overall Screened Multi-Pair Cable (Belden Equivalent) provides protection against electrical interference. Suitable for use over long distances at high performance levels and where low signal distortion is required. Used for instrumentation control and RS232 applications.
Standards: RS232
Overall Screened Multi-Core Cable (Belden Equivalent)
Toggle
Eland Product Group: A3B
Application: Overall Screened Multi-Core Cable (Belden Equivalent) RS232 data cable is a general purpose overall screened cable. With protection against electrical interference, this cable is suitable for RS232 applications.
Standards: RS232
Overall Foil and Braid Screened Cable (Belden Equivalent)
Toggle
Eland Product Group: A3B
Application: Overall Foil and Braid Screened Cable (Belden Equivalent) is a 24 AWG low capacitance cable with a high level of screening. Provides interference free, high speed data transmission suitable for RS485 applications.
Standards: RS485
NSHTOU Cable
Toggle
Eland Product Group: A5N
Application: For use in hoists, transporting machines and conveyors, in power chains, as drum and drag cables and as hawsers. Wherever cables are reeled, unreeled, guided by roller trains or similar.
Standards: VDE0250, VDE0293
High Temperature Silicone Cable
Toggle
Eland Product Group: ASI
Application: Typical industrial applications include food processing, packaging, refrigeration, furnaces and lighting.
Standards: SIA/SIAF
Elevator Cable / Flatform Cable H05VVH6-F
Toggle
Eland Product Group: A1TR
Application: Elevator/Flatform Cable is a flat traveling PVC Cable used in conveyor and hoist equipment. This cable is suitable for internal and panoramic elevator applications with a freely suspended length up to 45 metres.
Standards: BS EN 50214
CW1308B Internal/External Telecom Cable
Toggle
Eland Product Group: A8T
Application: Cables primarily designed for the interconnection of telephone equipment both internally and externally. In addition these cables may be used for the interconnection of other communication and control equipment or low level signalling applications. The cable specification is further enhanced by the use of a Low Smoke Zero Halogen outer sheath.
Standards: CW1308, IEC 60754-1
CW1308 Internal Telecom Cable
Toggle
Eland Product Group: A8T
Application: Cables primarily designed for the interconnection of telephone equipment which is installed indoors. In addition these cables may be used for the interconnection of other communication and control equipment or low level signalling applications.
Standards: CW1308
CW1128/1198 Direct Burial Telephone Cable
Toggle
Eland Product Group: A8T
Application: External armoured cable primarily designed for the interconnection of telephone equipment. Suitable for direct burial. UV and moisture resistant. In addition these cables may be used for interconnection of other communication and control equipment or low level signaling applications
Standards: CW1128/1198
CW1128 Telephone Cable
Toggle
Eland Product Group: A8T
Application: Cables primarily designed for the interconnection of telephone equipment. In addition these cables may be used for interconnection of other communication and control equipment or low level signalling applications.
Standards: CW1128
Curly Flex TPR Cable
Toggle
Eland Product Group: A2C
Application: Intended for use in machinery, lifting platforms, conveyor and transport belts, agricultural equipment, construction machinery or trucks with high chemical, thermal or mechanical stress.
Conductor: Class 5 flexible tinned copper conductors to BS EN 60228:2005 (previously BS6360)
Coil End Lead Cable to BS6195
Toggle
Eland Product Group: A6K
Application: Coil leads are used mainly in electrical machinery and panel wiring. The HOFR sheath resists oil and varnish and the stranding is designed as a compromise between flexibility and positional stability. Also suitable as an alternative to tri-rated and bi-rated cable in certain applications.
Standards: BS6195 Type 4
Cat 6 LSZH Cable
Toggle
Eland Product Group: A8N
Application: A multipair (usually 4 pair) high
performance cable that consists of
twisted pair conductors, used mainly
for data transmission.
Category 6 is recommended for
all new and existing installations, supports a
frequency range of up to 250MHz
and is designed for transmission
speeds of up to 1 gigabit per
second (Gigabit Ethernet).
Read more about LAN Cables and the differences between these types of data cables.
Standards: ISO/IEC11801, TIA/EIA 568B
Cat 5E UTP PE External Cable
Toggle
Eland Product Group: A8N
Application: A multipair (usually 4 pair) high
performance cable that consists of
twisted pair conductors, used mainly
for data transmission. Category
5 E is recommended for all new and existing
installations, supports a frequency
range of up to 100MHz and is
designed for transmission speeds of
up to 1 gigabit per second (Gigabit
Ethernet). Cat 5E UTP is suitable for
outdoor use.
Read more about LAN Cables and the differences between these types of data cables.
Standards: ISO/IEC 11801, TIA/EIA 568B
Cat 5E UTP LSZH Cable
Toggle
Eland Product Group: A8N
Application: A multipair (usually 4 pair) high performance cable that consists of twisted pair conductors, used mainly for data transmission. Category 5 E is recommended for all new and existing installations, supports a frequency range of up to 100MHz and is designed for transmission speeds of up to 1 gigabit per second (Gigabit Ethernet).
Read more about LAN Cables and the differences between these types of data cables.
Standards: ISO/IEC11801, TIA/EIA 568B
6491X Cable H07V-R/H07V-U to BS6004
Toggle
Eland Product Group: A2X
Application: 6491X Cable H07V-R/H07V-U to BS6004 is suitable for power and lighting circuits and building wiring. The cable is intended for use in semi-flush exposed conduits and embedded conduits as well as in closed installation ducts, and is ideal for the internal wiring of appliances and apparatus.
Standards: BS6004, BASEC approved*
6491B Conduit Wiring Cable H07Z-R to BS7211
Toggle
Eland Product Group: A3Z
Application: Suitable for use in conduit and for fixed, protected installation. In particular for installation where fire, smoke emission and toxic fumes create a potential threat.
Standards: BS7211, BASEC approved*, BS EN/IEC 60228
H07BN4-F Cable (6381TQ) to BS7919
Toggle
Eland Product Group: A6Q
Application: For connecting equipment such as pumps, generators and lighting to the mains supply and generally for use in arduous industrial environments where good flexibility and resistance to mechanical abrasion is essential.
Read more about H07BN4-F Cables and their applications.
Standards:
BS7919 (Superseded BS6007 in 2003)
CEI 20-19/13
20-35 (EN60332-1) / 20-22III (EN50266) / 20-37 (EN50267)
CENELEC HD22.13.S1/A1
33kV XLPE Cable
Toggle
Eland Product Group: A9M
Application: Power cables for power networks, underground, outdoors and in cable ducting.
Standards: BS6622
318-B LSZH Cable H05Z1Z1-F
Toggle
Eland Product Group: A5Z
Application: Used as an indoor general wiring cable primarily for installations in public areas. Examples include use on pendant lighting drops or as a general supply lead within hospital or airport projects. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment.
Standards: IEC 60092-353
11kV XLPE PVC Cable
Toggle
Eland Product Group: A9M
Application: Power cables for power networks, underground, outdoors and in cable ducting.
Standards: BS6622, BS EN/IEC 60228
11kV XLPE LSZH Cable BS7835
Toggle
Eland Product Group: A9M
Application: Power cables for power networks, underground, outdoors and in cable ducting. In particular for installation where fire, smoke emission and toxic fumes create a potential threat.
Standards: BS7835, IEC 60754-1
Coaxial BT3002/RA7000 Eq. Cable
Toggle
Eland Product Group: A7E
Application: Manufactured to BT specifications and used for interconnecting of data or telecoms equipment.
Read more about Coaxial Cable.
Conductor: Solid plain copper
Coaxial RG/URM/Composite Cable
Toggle
Eland Product Group: A7E
Application: High quality RG Type Coaxial cables, 50 or 75 Ohm is suitable for many applications, including low power video, video signal, and broadband signals. Many types are available in Duct Grade, LSF or LSZH versions.
Conductor:
RG6: CCS (Copper Clad Steel)
RG11: TCW (Tinned Copper Wire)
RG58: TCW (Tinned Copper Wire)
RG59: CCS (Copper Clad Steel)
RG179: TCW (Tinned Copper Wire)
RG213 PVC: PCW (Plain Copper Wire)
RG213 LSZH: PCW (Plain Copper Wire)
URM67: PCW (Plain Copper Wire)
URM70: PCW (Plain Copper Wire)
75 Ohm Coax + 1Pair: PCW (Plain Copper Wire)
+ TCW (Tinned Copper Wire)
75 Ohm Coax + 1Pair: PCW (Plain Copper Wire)
+ TCW (Tinned Copper Wire)
Curly Flex PVC Cable
Toggle
Eland Product Group: A2C
Application: For use in domestic appliances, ceiling to display or cash desk equipment and indoor lighting features.
Conductor: Class 5 flexible plain copper conductors to BS EN 60228:2005 (previously BS6360), VDE0295
Curly Flex PUR Cable
Toggle
Eland Product Group: A2C
Application: For use in power tools, hoists, scissor lifts and roller doors within harsh industrial environments.
Conductor: Class 5 flexible plain copper conductors to BS EN 60228:2005 (previously BS6360), VDE0295
RV-K Powerflex Cable
Toggle
Eland Product Group: A9R
Application: A flexible power and control cable designed for fixed applications. Manufactured with flexible conductors in order to facilitate installations with sinuous courses.
Standards: UNE 21123-2, 60502-1, EN 50265, IEC 60332-1
RIA21 Cable
Toggle
Eland Product Group: A6R
Application: Cables are designed for use in protected or exposed installation on traction and rolling stock within vehicles. May also find application in the connection of coil winding and flexible power leads.
Standards: RIA21
H07ZZ-F Cable
Toggle
Eland Product Group: A6G and A5G
Application: For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Examples of use include supplying mobile power units, UPS installations, stage lighting and audio visual equipment. This cable will withstand medium mechanical stresses and is suitable for both installation indoors and outdoors.
Standards:
CENELEC HD22-13
NFC 032-131
IEC 60332-3
NHXMH-J Cable
Toggle
Eland Product Group: A9H
Application: These cables are intended for fixed installation in dry and moist rooms as well as in masonry and concrete, in and under plaster; not for underground installation. NHXMH-J/O are especially used in buildings with a high concentration of persons or valuable property, where improved fire characteristics are needed. This product conforms to 73/23/EW G directive (low voltage directive) CE.
Standards: VDE 0250 (part 214), VDE 0482 (part 266-2-4, test type C)