
Armoured Cable
Control Flexible Cable
Rubber Flexible Cable
PVC Flexible Cable
High Temperature Cable
Fixed Wiring Cable
LSZH Flexible Cable
BS5308 Instrumentation Cable
Belden Cable
Belden Alternative Cable
Fire Performance Cable
Coaxial Cable
Data Cable
Telephone Cable
Defence Standard Cable
Aluminium Conductors
Profibus and Profinet Cable
Welding Cable
Solar Cable
Signalling Cable
Power Cable
Earthing Cable
Telecom Cable
Points Heating Cable
Overhead Line Cable
Rolling Stock
Your Industry
Automation and Process Control
Cables sourced from Eland Cables help ensure the continuous operation of automated processes, preventing costly down time in businesses which are increasingly operating production lines on a 24/7 basis. Whether supplying cables for power distribution to automated machinery, production plant and safety systems – or data communications cable for the smooth running and control of the factory floor – there is a high quality solution that users can rely on.
Unplanned maintenance can cost hundreds of thousands of pounds. However, Eland Cables offers peace of mind and helps safeguard the integrity of an installation by ensuring cables are subjected to rigorous physical testing and quality assurance.
The company’s control cables provide interference-free data and signal transmission, while meeting stringent safety standards, and are routinely used for machine tool manufacturing, plant engineering and assembly lines. Data cables can also be provided to meet the exacting demands of defence standards 61/12 parts 4 and 5, along with tri rated cables to meet BS, UL and CSA standards.
Tri-rated Cable (H07V2-K) to BS6231
Toggle
Eland Product Group: A2T
Application: Tri-rated Cable panel wiring is a high temperature, flame retardant cable designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers. Tri-rated Cable is sometimes referred to as BS6231 Cable, H07V2-K or Panel Wire.
Standards:
BS6231 Type CK
UL Subj.758
CSA c.22.2 No. 127 (only applicable for
sizes up to 120mm²)
HD 21.7 S2*
SWA Cable - BS5467 Steel Wire Armoured PVC
Toggle
Eland Product Group: A9S
Application: SWA Cable - power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting.
Standards: BS5467, IEC 60502
CY Control Flexible Cable to BS6500
Toggle
Eland Product Group: A5C
Application: Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use when temporarily moved, and in conditions of medium mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
Standards: Generally to BS6500
CY LSZH Control Flexible Cable to BS6500
Toggle
Eland Product Group: A5B
Application: For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use when temporarily moved, and in conditions of medium mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
Standards: Generally to BS6500, IEC 60754-1
YY Control Flexible Cable to BS6500
Toggle
Eland Product Group: A5Y
Application: Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
Standards: Generally to BS6500, VDE0250
YY LSZH Control Flexible Cable to BS6500
Toggle
Eland Product Group: A5L
Application: For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
Standards: Generally to BS6500, VDE0250, IEC 60332-3, IEC 60754-1
SY Control Flexible Cable to BS6500
Toggle
Eland Product Group: A5J
Application: Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
The braided screen offers the best possible protection against mechanical damage and offers a level of Electro-magnetic shielding. The galvanised coating helps protect against corrosion.
Standards: Generally to BS6500, VDE0250
BS5308 Instrumentation Cable Part 1 Type 1
Toggle
Eland Product Group: A3I
Application: BS5308 cables are used to carry voice and data services, they also serve as the interconnection between electrical equipment and instruments, particularly in and around process plants, where transducer generated signals are transmitted through to panels, controllers and other devices.
Standards: BS5308 Part 1, BS EN/IEC 60228
H07RN-F Cable to BS7919
Toggle
Eland Product Group: A6G and A5G
Application: These cables are designed to provide high flexibility and have
the capacity to withstand weather,
oils/greases, mechanical and thermal stresses. Applications include handling equipment, mobile power supplies, worksites, stage and audio visual equipment, port areas and dams. Also for use in drainage and water treatment, cold environments and severe industrial environments.
Read more about H07RN-F Cables and their applications.
Standards: BS7919, CENELEC HD22.4 S4
SWA Cable - BS6724 Steel Wire Armoured LSZH
Toggle
Eland Product Group: A9L
Application: SWA Cable - power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment.
Standards: BS6724, IEC 60754-1
Overall Screened Single Pair Cable (Belden Equivalent)
Toggle
Eland Product Group: A3B
Application: Overall Screened Single Pair Cable (Belden Equivalent) is suitable for use in instrumentation, data and audio applications where protection against electrical interference is required. Cables with polyethylene insulation show lower signal loss than those using PVC.
Conductor: Stranded tinned copper
Overall Screened Multi-Pair Cable (Belden Equivalent)
Toggle
Eland Product Group: A3B
Application: Overall Screened Multi-Pair Cable (Belden Equivalent) provides protection against electrical interference. Suitable for use over long distances at high performance levels and where low signal distortion is required. Used for instrumentation control and RS232 applications.
Standards: RS232
Overall Screened Multi-Core Cable (Belden Equivalent)
Toggle
Eland Product Group: A3B
Application: Overall Screened Multi-Core Cable (Belden Equivalent) RS232 data cable is a general purpose overall screened cable. With protection against electrical interference, this cable is suitable for RS232 applications.
Standards: RS232
Overall Foil and Braid Screened Cable (Belden Equivalent)
Toggle
Eland Product Group: A3B
Application: Overall Foil and Braid Screened Cable (Belden Equivalent) is a 24 AWG low capacitance cable with a high level of screening. Provides interference free, high speed data transmission suitable for RS485 applications.
Standards: RS485
NSHTOU Cable
Toggle
Eland Product Group: A5N
Application: For use in hoists, transporting machines and conveyors, in power chains, as drum and drag cables and as hawsers. Wherever cables are reeled, unreeled, guided by roller trains or similar.
Standards: VDE0250, VDE0293
NSGAFOU Cable
Toggle
Eland Product Group: A5N
Application: Single core cable for use in switch cabinets, wiring of devices, trains and buses as well as in dry rooms.
Standards: DIN VDE 0250-602
Multi-Core Data Cables to Def Stan 61/12 Part 5
Toggle
Eland Product Group: A2D
Application: These multicore flexible cables are designed for high density wiring between components and within instruments and electronic equipment. They are extensively used in aircraft, process control systems, computers, data processors, military vehicles and military equipment.
Standards: Generally to Def Stan 61-12 Part 5
Multi-Core Data Cables to Def Stan 61/12 Part 4
Toggle
Eland Product Group: A2D
Application: These Multi-Core flexible cables are designed for high density wiring between components and within instruments and electronic equipment. They are extensively used in aircraft, process control systems, computers, data processors, military vehicles and military equipment.
Standards: Generally to Def. Stan 61-12 Part 4
BS5308 Instrumentation Cable Part 1 Type 2
Toggle
Eland Product Group: A3I
Application: BS5308 cables are used to carry voice and data services, they also serve as the interconnection between electrical equipment and instruments, particularly in and around process plants, where transducer generated signals are transmitted through to panels, controllers and other devices.
Standards: BS5308 Part 1, BS EN/IEC 60228
Individually Screened Multi-Pair Cable (Belden Equivalent)
Toggle
Eland Product Group: A3B
Application: Individually Screened Multi-Pair Cable (Belden Equivalent) is designed to prevent cross-talk between pairs and ensures excellent protection from electrical interference. Suitable for instrumentation, computer and security applications, point of sale, control systems, and RS232 applications.
Conductor: Stranded tinned copper
Elevator Cable / Flatform Cable H05VVH6-F
Toggle
Eland Product Group: A1TR
Application: Elevator/Flatform Cable is a flat traveling PVC Cable used in conveyor and hoist equipment. This cable is suitable for internal and panoramic elevator applications with a freely suspended length up to 45 metres.
Standards: BS EN 50214
Curly Flex TPR Cable
Toggle
Eland Product Group: A2C
Application: Intended for use in machinery, lifting platforms, conveyor and transport belts, agricultural equipment, construction machinery or trucks with high chemical, thermal or mechanical stress.
Conductor: Class 5 flexible tinned copper conductors to BS EN 60228:2005 (previously BS6360)
Coil End Lead Cable to BS6195
Toggle
Eland Product Group: A6K
Application: Coil leads are used mainly in electrical machinery and panel wiring. The HOFR sheath resists oil and varnish and the stranding is designed as a compromise between flexibility and positional stability. Also suitable as an alternative to tri-rated and bi-rated cable in certain applications.
Standards: BS6195 Type 4
2491B / 6701B Flexible Cable H05Z-K/H07Z-K to BS7211
Toggle
Eland Product Group: A2Z
Application: In pipes or ducts and internal wiring of appliances with maximum operating temperatures of 90°C, and generally in areas (such as public and government buildings) where smoke and toxic fumes may cause a threat to life and equipment. The cables produce no corrosive gasses when burnt which is particularly important where electronic equipment is installed.
Standards: BS7211, CENELEC HD22.9, IEC 60332-3-24
0361TQ Orange Welding Cable to BS638
Toggle
Eland Product Group: A1E
Application: For the transmission of high currents from the electric welding machine to the welding tool. Suitable for flexible use under rough conditions, on assembly lines and conveyor systems, in machine tool and motor car manufacturing, ship building, for manually and automatically operated line and spot welding machines.
Standards: BS638 Part 4* BS EN 60332-1-2
0361TQ Black Welding Cable to BS638
Toggle
Eland Product Group: A1G
Application: For the transmission of high currents from the electric welding machine to the welding tool. Suitable for flexible use under rough conditions, on assembly lines and conveyor systems, in machine tool and motor car manufacturing, ship building, for manually and automatically operated line and spot welding machines.
Standards: BS638 Part 4* BS EN 60332-1-2
Elandflex Cable
Toggle
Eland Product Group: A2F
Application: Highly flexible single core conductors with a great variety of industrial applications, such as cable harnesses, panel wiring and power generation.
Standards: IEC 60332-1
2491X Flexible Cable H05V-K H07V-K to BS6004
Toggle
Eland Product Group: A5V
Application: Designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers.
Standards: BS6004, CENELEC HD21.3
Curly Flex PVC Cable
Toggle
Eland Product Group: A2C
Application: For use in domestic appliances, ceiling to display or cash desk equipment and indoor lighting features.
Conductor: Class 5 flexible plain copper conductors to BS EN 60228:2005 (previously BS6360), VDE0295
Curly Flex PUR Cable
Toggle
Eland Product Group: A2C
Application: For use in power tools, hoists, scissor lifts and roller doors within harsh industrial environments.
Conductor: Class 5 flexible plain copper conductors to BS EN 60228:2005 (previously BS6360), VDE0295
Intemp 250 Cable
Toggle
Eland Product Group: A8I
Application: This high performance cable is designed to operate under more arduous high temperature conditions, providing moisture resistance, toughness, flexibility and a continous conductor operating temperature of 250°C.
Conductor: Class 5 flexible nickel-plated copper conductor
H07ZZ-F Cable
Toggle
Eland Product Group: A6G and A5G
Application: For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Examples of use include supplying mobile power units, UPS installations, stage lighting and audio visual equipment. This cable will withstand medium mechanical stresses and is suitable for both installation indoors and outdoors.
Standards:
CENELEC HD22-13
NFC 032-131
IEC 60332-3
Profibus PA Cable
Toggle
Eland Product Group: A3P
Application: For the cabling of industrial field bus systems particularly developed for process automation and instrumentation application in hazardous and intrinsically safe areas.
Filler: Unspecified material
Profibus DP Q-Strip Cable
Toggle
Eland Product Group: A3P
Application: For the cabling of industrial field bus systems, particularly developed for factory automation applications.
Standards: IEC 60754-1*
