Your Industry

Building and Construction

Electrical Cables - Building and Construction Eland Cables supplies quality solutions to the building and construction market, which are keenly priced to give contractors a competitive edge when tendering for business. The company helps keep costs low, which is key to maximising profit margins, but also offers installers peace of mind that the integrity and safety of their installation will be ensured by using cables from the most respected and trusted suppliers.

On mission critical applications such as emergency power in hospitals, or fire alarms and emergency lighting in safety conscious public buildings, contractors can be confident they are installing solutions they can depend on. The company's cables are used extensively in power networks, emergency power applications, security and alarm circuits, lighting, building management and control systems, elevators and escalators, data infrastructure and much more.

There is a solution to meet the needs of every application – from high temperature silicone cable for lighting applications, to arctic grade cable for site services. Our team of industry experts can offer advice on choosing the right cable to meet the appropriate industry standards, as well as directives such as RoHS, to help ensure your installation meets the latest regulations.

For contractors that need to keep stockholding on site to a minimum, Eland offers just-in-time delivery. Customers can be sure that cable supply will not hold up building works as it also boasts an on time delivery rate of over 98%. Not only does Eland take your deadlines as seriously as you do, it can also offer a project-based, cable cutting service which ultimately means less waste, faster installation and reduced costs on both skilled labour and materials. As building projects increasingly focus on sustainability, reduced waste will also contribute to delivering environmental benefits.

SWA Cable - BS5467 Steel Wire Armoured PVCSWA Cable - BS5467 Steel Wire Armoured PVC Toggle

Eland Product Group: A9S

Application: SWA Cable - power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting.

Standards: BS5467, IEC 60502

Full Product Specification

Tri-rated Cable (H07V2-K) to BS6231Tri-rated Cable (H07V2-K) to BS6231 Toggle

Eland Product Group: A2T

Application: Tri-rated Cable panel wiring is a high temperature, flame retardant cable designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers. Tri-rated Cable is sometimes referred to as BS6231 Cable, H07V2-K or Panel Wire.

Standards:
BS6231 Type CK
UL Subj.758
CSA c.22.2 No. 127 (only applicable for sizes up to 120mm²)
HD 21.7 S2*

Full Product Specification

CY Control Flexible Cable to BS6500CY Control Flexible Cable to BS6500 Toggle

Eland Product Group: A5C

Application: Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use when temporarily moved, and in conditions of medium mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.

Standards: Generally to BS6500

Full Product Specification

CY LSZH Control Flexible Cable to BS6500CY LSZH Control Flexible Cable to BS6500 Toggle

Eland Product Group: A5B

Application: For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use when temporarily moved, and in conditions of medium mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.

Standards: Generally to BS6500, IEC 60754-1

Full Product Specification

YY Control Flexible Cable to BS6500YY Control Flexible Cable to BS6500 Toggle

Eland Product Group: A5Y

Application: Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.

Standards: Generally to BS6500, VDE0250

Full Product Specification

SY Control Flexible Cable to BS6500SY Control Flexible Cable to BS6500 Toggle

Eland Product Group: A5J

Application: Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
The braided screen offers the best possible protection against mechanical damage and offers a level of Electro-magnetic shielding. The galvanised coating helps protect against corrosion.

Standards: Generally to BS6500, VDE0250

Full Product Specification

BS5308 Instrumentation Cable Part 1 Type 1BS5308 Instrumentation Cable Part 1 Type 1 Toggle

Eland Product Group: A3I

Application: BS5308 cables are used to carry voice and data services, they also serve as the interconnection between electrical equipment and instruments, particularly in and around process plants, where transducer generated signals are transmitted through to panels, controllers and other devices.

Standards: BS5308 Part 1, BS EN/IEC 60228

Full Product Specification

H07RN-F Cable to BS7919H07RN-F Cable to BS7919 Toggle

Eland Product Group: A6G and A5G

Application: These cables are designed to provide high flexibility and have the capacity to withstand weather, oils/greases, mechanical and thermal stresses. Applications include handling equipment, mobile power supplies, worksites, stage and audio visual equipment, port areas and dams. Also for use in drainage and water treatment, cold environments and severe industrial environments.

Read more about H07RN-F Cables and their applications.

Standards: BS7919, CENELEC HD22.4 S4

Full Product Specification

SWA Cable - BS6724 Steel Wire Armoured LSZHSWA Cable - BS6724 Steel Wire Armoured LSZH Toggle

Eland Product Group: A9L

Application: SWA Cable - power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment.

Standards: BS6724, IEC 60754-1

Full Product Specification

Cat 5E UTP PVC CableCat 5E UTP PVC Cable Toggle

Eland Product Group: A8N

Application: A multipair (usually 4 pair) high performance cable that consists of twisted pair conductors, used mainly for data transmission. Category 5E is recommended for all new and existing installations, supports a frequency range of up to 100MHz and is designed for transmission speeds of up to 1 gigabit per second (Gigabit Ethernet).

Read more about LAN Cables and the differences between these types of data cables.

Standards: ISO/IEC11801, TIA/EIA 568B

Full Product Specification

Twinflex Battery CableTwinflex Battery Cable Toggle

Eland Product Group: A1T

Application: For indoors and outdoors, in dry as well as wet location on motorised vehicles, or battery powered equipment such as fork lifts and field conveyors. Also in high quality booster cables.

Standards: Figure 8 configuration based on VDE0250

Full Product Specification

Alarm Cable - TCCAAlarm Cable - TCCA Toggle

Eland Product Group: A3A

Application: Flexible alarm cable used for the wiring of burglar alarms and other low voltage circuits.

Conductor: TCCA (Tinned Copper Clad Aluminium)

Full Product Specification

Overall Screened Single Pair Cable  (Belden Equivalent)Overall Screened Single Pair Cable (Belden Equivalent) Toggle

Eland Product Group: A3B

Application: Overall Screened Single Pair Cable (Belden Equivalent) is suitable for use in instrumentation, data and audio applications where protection against electrical interference is required. Cables with polyethylene insulation show lower signal loss than those using PVC.

Conductor: Stranded tinned copper

Full Product Specification

Overall Screened Multi-Pair Cable  (Belden Equivalent)Overall Screened Multi-Pair Cable (Belden Equivalent) Toggle

Eland Product Group: A3B

Application: Overall Screened Multi-Pair Cable (Belden Equivalent) provides protection against electrical interference. Suitable for use over long distances at high performance levels and where low signal distortion is required. Used for instrumentation control and RS232 applications.

Standards: RS232

Full Product Specification

Overall Screened Multi-Core Cable  (Belden Equivalent)Overall Screened Multi-Core Cable (Belden Equivalent) Toggle

Eland Product Group: A3B

Application: Overall Screened Multi-Core Cable (Belden Equivalent) RS232 data cable is a general purpose overall screened cable. With protection against electrical interference, this cable is suitable for RS232 applications.

Standards: RS232

Full Product Specification

NYY-J CableNYY-J Cable Toggle

Eland Product Group: A9N

Application: Power and control cable for fixed installation. Can be used indoors, outdoors, underground, in concrete and in water.

Standards: IEC60502-1
Generally to VDE0276 and VDE0271.

Full Product Specification

Multi-Core Data Cables to Def Stan 61/12 Part 5Multi-Core Data Cables to Def Stan 61/12 Part 5 Toggle

Eland Product Group: A2D

Application: These multicore flexible cables are designed for high density wiring between components and within instruments and electronic equipment. They are extensively used in aircraft, process control systems, computers, data processors, military vehicles and military equipment.

Standards: Generally to Def Stan 61-12 Part 5

Full Product Specification

Multi-Core Data Cables to Def Stan 61/12 Part 4Multi-Core Data Cables to Def Stan 61/12 Part 4 Toggle

Eland Product Group: A2D

Application: These Multi-Core flexible cables are designed for high density wiring between components and within instruments and electronic equipment. They are extensively used in aircraft, process control systems, computers, data processors, military vehicles and military equipment.

Standards: Generally to Def. Stan 61-12 Part 4

Full Product Specification

BS5308 Instrumentation Cable Part 1 Type 2BS5308 Instrumentation Cable Part 1 Type 2 Toggle

Eland Product Group: A3I

Application: BS5308 cables are used to carry voice and data services, they also serve as the interconnection between electrical equipment and instruments, particularly in and around process plants, where transducer generated signals are transmitted through to panels, controllers and other devices.

Standards: BS5308 Part 1, BS EN/IEC 60228

Full Product Specification

Individually Screened Multi-Pair Cable (Belden Equivalent)Individually Screened Multi-Pair Cable (Belden Equivalent) Toggle

Eland Product Group: A3B

Application: Individually Screened Multi-Pair Cable (Belden Equivalent) is designed to prevent cross-talk between pairs and ensures excellent protection from electrical interference. Suitable for instrumentation, computer and security applications, point of sale, control systems, and RS232 applications.

Conductor: Stranded tinned copper

Full Product Specification

High Temperature Silicone CableHigh Temperature Silicone Cable Toggle

Eland Product Group: ASI

Application: Typical industrial applications include food processing, packaging, refrigeration, furnaces and lighting.

Standards: SIA/SIAF

Full Product Specification

Firecel SR 114E Enhanced Fire Cable PH120Firecel SR 114E Enhanced Fire Cable PH120 Toggle

Eland Product Group: A6F

Application: Firecel SR 114E Fire Performance Cable is intended for use in fire detection and fire alarm systems, and emergency lighting circuits. Firecel 114E Enhanced cable is recommended for situations where fire cables may need to remain operating correctly for a longer period than is expected of a standard fire cable. For example, in buildings without sprinkler systems, which have a longer evacuation process due to the size, complexity or purpose of the building, or any building that has been assessed as requiring enhanced fire protection.

Standards:
BS 5839-1:2002
Code of practice for fire system design, installation, commissioning and maintenance.

BS 7629-1:2008
Low emission of smoke and corrosive gases

BS EN 50200 PH120
Temperature: 830 °C
Flame and shock for 120 minutes

BS 8434-2:2003 +A2:2009
Temperature: 930 °C
Flame and shock for 60 minutes.
+ flame, shock and water for 60 minutes

BS 6387
Category C-W-Z
C - Resistance to fire at 950ºC for 3 hours
W - Resistance to fire with water at 950ºC for 3 hours
Z - Resistance to fire with mechanical shock at 950ºC for 3 hours

LPCB approved
LPCB Logo
Download Firecel SR 114E LPCB Certification as a pdf

Full Product Specification

Festoon Cable - InternalFestoon Cable - Internal Toggle

Eland Product Group: A5F

Application: Use Indoors

Standards: IEC60502

Full Product Specification

Festoon Cable - External H05RNH-FFestoon Cable - External H05RNH-F Toggle

Eland Product Group: A5F

Application: Flexible cords suitable for use in domestic premises, kitchens and offices. Also suitable for use in hot situations such as immersion heaters. Good resistance to oil and grease.

Standards: IEC 60598-1, H05RNH-F

Full Product Specification

Elevator Cable / Flatform Cable H05VVH6-F Elevator Cable / Flatform Cable H05VVH6-F Toggle

Eland Product Group: A1TR

Application: Elevator/Flatform Cable is a flat traveling PVC Cable used in conveyor and hoist equipment. This cable is suitable for internal and panoramic elevator applications with a freely suspended length up to 45 metres.

Standards: BS EN 50214

Full Product Specification

CW1308B Internal/External Telecom CableCW1308B Internal/External Telecom Cable Toggle

Eland Product Group: A8T

Application: Cables primarily designed for the interconnection of telephone equipment both internally and externally. In addition these cables may be used for the interconnection of other communication and control equipment or low level signalling applications. The cable specification is further enhanced by the use of a Low Smoke Zero Halogen outer sheath.

Standards: CW1308, IEC 60754-1

Full Product Specification

CW1308 Internal Telecom CableCW1308 Internal Telecom Cable Toggle

Eland Product Group: A8T

Application: Cables primarily designed for the interconnection of telephone equipment which is installed indoors. In addition these cables may be used for the interconnection of other communication and control equipment or low level signalling applications.

Standards: CW1308

Full Product Specification

CW1128/1198 Direct Burial Telephone CableCW1128/1198 Direct Burial Telephone Cable Toggle

Eland Product Group: A8T

Application: External armoured cable primarily designed for the interconnection of telephone equipment. Suitable for direct burial. UV and moisture resistant. In addition these cables may be used for interconnection of other communication and control equipment or low level signaling applications

Standards: CW1128/1198

Full Product Specification

CW1128 Telephone CableCW1128 Telephone Cable Toggle

Eland Product Group: A8T

Application: Cables primarily designed for the interconnection of telephone equipment. In addition these cables may be used for interconnection of other communication and control equipment or low level signalling applications.

Standards: CW1128

Full Product Specification

Curly Flex TPR CableCurly Flex TPR Cable Toggle

Eland Product Group: A2C

Application: Intended for use in machinery, lifting platforms, conveyor and transport belts, agricultural equipment, construction machinery or trucks with high chemical, thermal or mechanical stress.

Conductor: Class 5 flexible tinned copper conductors to BS EN 60228:2005 (previously BS6360)

Full Product Specification

Coaxial CT CableCoaxial CT Cable Toggle

Eland Product Group: A7E

Application: Ideal for professional TV and CCTV system installations including digital satellite, terrestrial and Cable TV.

Which CT Cable is right for me?

Read more about Coaxial Cable.

Conductor: Solid plain copper

Full Product Specification

Cat 6 LSZH CableCat 6 LSZH Cable Toggle

Eland Product Group: A8N

Application: A multipair (usually 4 pair) high performance cable that consists of twisted pair conductors, used mainly for data transmission. Category 6 is recommended for all new and existing installations, supports a frequency range of up to 250MHz and is designed for transmission speeds of up to 1 gigabit per second (Gigabit Ethernet).

Read more about LAN Cables and the differences between these types of data cables.

Standards: ISO/IEC11801, TIA/EIA 568B

Full Product Specification

Cat 5E UTP PE External CableCat 5E UTP PE External Cable Toggle

Eland Product Group: A8N

Application: A multipair (usually 4 pair) high performance cable that consists of twisted pair conductors, used mainly for data transmission. Category 5 E is recommended for all new and existing installations, supports a frequency range of up to 100MHz and is designed for transmission speeds of up to 1 gigabit per second (Gigabit Ethernet). Cat 5E UTP is suitable for outdoor use.

Read more about LAN Cables and the differences between these types of data cables.

Standards: ISO/IEC 11801, TIA/EIA 568B

Full Product Specification

Cat 5E UTP LSZH CableCat 5E UTP LSZH Cable Toggle

Eland Product Group: A8N

Application: A multipair (usually 4 pair) high performance cable that consists of twisted pair conductors, used mainly for data transmission. Category 5 E is recommended for all new and existing installations, supports a frequency range of up to 100MHz and is designed for transmission speeds of up to 1 gigabit per second (Gigabit Ethernet).

Read more about LAN Cables and the differences between these types of data cables.

Standards: ISO/IEC11801, TIA/EIA 568B

Full Product Specification

Arctic Grade CableArctic Grade Cable Toggle

Eland Product Group: A5A

Application: Designed to withstand severe external temperatures remaining flexible at temperatures as low as -40°C. Arctic Grade PVC mains cords manufactured to BS7919 will remain flexible at temperatures down to minus 40°C making them particularly suitable for outdoor applications and for use where flexibility is required at sub zero temperatures. At normal temperatures the cable is very limp and flexible, offering some of the characteristics usually found in elastomeric cables.

Standards: BS7919 Table 44, VDE281

Full Product Specification

6491X Cable H07V-R/H07V-U to BS60046491X Cable H07V-R/H07V-U to BS6004 Toggle

Eland Product Group: A2X

Application: 6491X Cable H07V-R/H07V-U to BS6004 is suitable for power and lighting circuits and building wiring. The cable is intended for use in semi-flush exposed conduits and embedded conduits as well as in closed installation ducts, and is ideal for the internal wiring of appliances and apparatus.

Standards: BS6004, BASEC approved*

Full Product Specification

6491B Conduit Wiring Cable H07Z-R to BS72116491B Conduit Wiring Cable H07Z-R to BS7211 Toggle

Eland Product Group: A3Z

Application: Suitable for use in conduit and for fixed, protected installation. In particular for installation where fire, smoke emission and toxic fumes create a potential threat.

Standards: BS7211, BASEC approved*, BS EN/IEC 60228

Full Product Specification

H07BN4-F Cable (6381TQ) to BS7919H07BN4-F Cable (6381TQ) to BS7919 Toggle

Eland Product Group: A6Q

Application: For connecting equipment such as pumps, generators and lighting to the mains supply and generally for use in arduous industrial environments where good flexibility and resistance to mechanical abrasion is essential.

Read more about H07BN4-F Cables and their applications.

Standards:
BS7919 (Superseded BS6007 in 2003)
CEI 20-19/13
20-35 (EN60332-1) / 20-22III (EN50266) / 20-37 (EN50267)
CENELEC HD22.13.S1/A1

Full Product Specification

6381 LSZH Cable6381 LSZH Cable Toggle

Eland Product Group: A1F LS

Application: Suitable for D.C. power supplies on Telecom equipment and power applications where flexibility is required. The cables produce no corrosive gases when burnt which is important where electronic equipment is installed.

Conductor: Class 5 flexible annealed plain copper conductors to BS EN 60228:2005 (previously BS6360)

Full Product Specification

6181Y Double Insulated Wiring Cable to BS60046181Y Double Insulated Wiring Cable to BS6004 Toggle

Eland Product Group: A1Y

Application: Fixed Installation in dry or damp areas for domestic and light industrial wiring.

Standards: BS6004

Full Product Specification

318-Y Cable H05VV-F to BS6500318-Y Cable H05VV-F to BS6500 Toggle

Eland Product Group: A5Y and A6Y

Application: For use in household appliances such as washing machines, spin dryers and refrigerators. Generally unsuitable for outdoor use or industrial applications.

Standards:
0.5 - 2.5mm² to BS6500,
4.0mm² to BS7919
6.0mm² generally to BS7919
VDE28
CENELEC HD21.5

Full Product Specification

318-B LSZH Cable H05Z1Z1-F318-B LSZH Cable H05Z1Z1-F Toggle

Eland Product Group: A5Z

Application: Used as an indoor general wiring cable primarily for installations in public areas. Examples include use on pendant lighting drops or as a general supply lead within hospital or airport projects. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment.

Standards: IEC 60092-353

Full Product Specification

309-Y Flexible Cable H05V2V2-F to BS6500309-Y Flexible Cable H05V2V2-F to BS6500 Toggle

Eland Product Group: A5Y

Application: Supply leads for use as 318-Y but particularly for use in high temperature zones, for internal wiring or supply cords to electrical apparatus. Not suitable for outdoor use.

Standards: BS6500, BS7919 above 4.0mm²

Full Product Specification

2491B / 6701B Flexible Cable H05Z-K/H07Z-K to BS72112491B / 6701B Flexible Cable H05Z-K/H07Z-K to BS7211 Toggle

Eland Product Group: A2Z

Application: In pipes or ducts and internal wiring of appliances with maximum operating temperatures of 90°C, and generally in areas (such as public and government buildings) where smoke and toxic fumes may cause a threat to life and equipment. The cables produce no corrosive gasses when burnt which is particularly important where electronic equipment is installed.

Standards: BS7211, CENELEC HD22.9, IEC 60332-3-24

Full Product Specification

2192Y Flexible Cable H03VVH2-F to BS65002192Y Flexible Cable H03VVH2-F to BS6500 Toggle

Eland Product Group: A3Y

Application: Used as an indoor general wiring cable primarily for installations in public areas. Examples include use on pendant lighting drops or as a general supply lead.

Standards: BS6500

Full Product Specification

218-Y Flexible Cable H03VV-F to BS6500218-Y Flexible Cable H03VV-F to BS6500 Toggle

Eland Product Group: A3Y

Application: Light duty cable for use in domestic premises, kitchens and offices. For use with light portable appliances such as radios, table lamps and office machines.

Standards: BS6500, CENELEC HD21.5, VDE 281

Full Product Specification

0361TQ Orange Welding Cable to BS6380361TQ Orange Welding Cable to BS638 Toggle

Eland Product Group: A1E

Application: For the transmission of high currents from the electric welding machine to the welding tool. Suitable for flexible use under rough conditions, on assembly lines and conveyor systems, in machine tool and motor car manufacturing, ship building, for manually and automatically operated line and spot welding machines.

Standards: BS638 Part 4* BS EN 60332-1-2

Full Product Specification

0361TQ Black Welding Cable to BS6380361TQ Black Welding Cable to BS638 Toggle

Eland Product Group: A1G

Application: For the transmission of high currents from the electric welding machine to the welding tool. Suitable for flexible use under rough conditions, on assembly lines and conveyor systems, in machine tool and motor car manufacturing, ship building, for manually and automatically operated line and spot welding machines.

Standards: BS638 Part 4* BS EN 60332-1-2

Full Product Specification

 6381Y Cable to BS6004 6381Y Cable to BS6004 Toggle

Eland Product Group: A1F

Application: Suitable for AC and DC power supplies on Telecom equipment and power applications where flexibility is required.

Standards: Generally to BS6004, BS EN/IEC 60228

Full Product Specification

Coaxial BT3002/RA7000 Eq. CableCoaxial BT3002/RA7000 Eq. Cable Toggle

Eland Product Group: A7E

Application: Manufactured to BT specifications and used for interconnecting of data or telecoms equipment.

Read more about Coaxial Cable.

Conductor: Solid plain copper

Full Product Specification

Coaxial RG/URM/Composite CableCoaxial RG/URM/Composite Cable Toggle

Eland Product Group: A7E

Application: High quality RG Type Coaxial cables, 50 or 75 Ohm is suitable for many applications, including low power video, video signal, and broadband signals. Many types are available in Duct Grade, LSF or LSZH versions.

Conductor:
RG6: CCS (Copper Clad Steel)
RG11: TCW (Tinned Copper Wire)
RG58: TCW (Tinned Copper Wire)
RG59: CCS (Copper Clad Steel)
RG179: TCW (Tinned Copper Wire)
RG213 PVC: PCW (Plain Copper Wire)
RG213 LSZH: PCW (Plain Copper Wire)
URM67: PCW (Plain Copper Wire)
URM70: PCW (Plain Copper Wire)
75 Ohm Coax + 1Pair: PCW (Plain Copper Wire) + TCW (Tinned Copper Wire)
75 Ohm Coax + 1Pair: PCW (Plain Copper Wire) + TCW (Tinned Copper Wire)

Full Product Specification

2491X Flexible Cable H05V-K H07V-K to BS6004 2491X Flexible Cable H05V-K H07V-K to BS6004 Toggle

Eland Product Group: A5V

Application: Designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers.

Standards: BS6004, CENELEC HD21.3

Full Product Specification

Curly Flex PVC CableCurly Flex PVC Cable Toggle

Eland Product Group: A2C

Application: For use in domestic appliances, ceiling to display or cash desk equipment and indoor lighting features.

Conductor: Class 5 flexible plain copper conductors to BS EN 60228:2005 (previously BS6360), VDE0295

Full Product Specification

Curly Flex PUR CableCurly Flex PUR Cable Toggle

Eland Product Group: A2C

Application: For use in power tools, hoists, scissor lifts and roller doors within harsh industrial environments.

Conductor: Class 5 flexible plain copper conductors to BS EN 60228:2005 (previously BS6360), VDE0295

Full Product Specification

Cat 5E PE FTP GSWB LSZH CableCat 5E PE FTP GSWB LSZH Cable Toggle

Eland Product Group: A8N

Application: Also known as Armoured Cat 5E Cable, this cable is used for horizontal wiring in a local area network (LAN) in areas requiring mechanical protection.

Read more about LAN Cables and the differences between these types of data cables.

Standards: ISO/IEC11801, TIA/EIA 568B

Full Product Specification

RV-K Powerflex CableRV-K Powerflex Cable Toggle

Eland Product Group: A9R

Application: A flexible power and control cable designed for fixed applications. Manufactured with flexible conductors in order to facilitate installations with sinuous courses.

Standards: UNE 21123-2, 60502-1, EN 50265, IEC 60332-1

Full Product Specification

H07ZZ-F CableH07ZZ-F Cable Toggle

Eland Product Group: A6G and A5G

Application: For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Examples of use include supplying mobile power units, UPS installations, stage lighting and audio visual equipment. This cable will withstand medium mechanical stresses and is suitable for both installation indoors and outdoors.

Standards:
CENELEC HD22-13
NFC 032-131
IEC 60332-3

Full Product Specification

NHXMH-J CableNHXMH-J Cable Toggle

Eland Product Group: A9H

Application: These cables are intended for fixed installation in dry and moist rooms as well as in masonry and concrete, in and under plaster; not for underground installation. NHXMH-J/O are especially used in buildings with a high concentration of persons or valuable property, where improved fire characteristics are needed. This product conforms to 73/23/EW G directive (low voltage directive) CE.

Standards: VDE 0250 (part 214), VDE 0482 (part 266-2-4, test type C)

Full Product Specification

NYCWY Power CableNYCWY Power Cable Toggle

Eland Product Group: A9N

Application: For use where increased electrical and mechanical protection is required, preferably for underground laying, especially in subscriber networks, power stations as well as control cables for the transmission of control impulses and test data.

Standards: VDE0276 part 603, CENELEC HD603 S1, IEC 60502

Full Product Specification

NYCY Power CableNYCY Power Cable Toggle

Eland Product Group: A9N

Application: For use indoors, in cable ducts, outdoors and in earth for power plants, industrial plants, as well as in local power networks, if increased mechanical and electrical protection is required.

Standards: VDE0276 part 603, CENELEC HD603 S1, IEC 60502
7 cores and above to VDE0276 part 627, CENELEC HD627 S1, IEC 60502

Full Product Specification