Your Industry

Communication and Telecommunication

Eland Cables - Communications and Telecommunication Eland Cables supplies a wide range of cables for fast and reliable transmission of data and telecommunications – from instrumentation control and computer applications, to interconnection of telephone equipment, audio and network infrastructures.

Sourced from the most respected manufacturers, there are a variety of high quality solutions available – designed to meet the demands of industry standards such as RS485, RS232 and RS422.

The company's extensive portfolio includes high performance Cat 5 and Cat 6 cables designed to support a frequency range of up to 100M Hz with transmission speeds of up to 1 gigabit per second (Gigabit Ethernet). Whether the installation requires screened multi pair or single pair cables, foil and braid screened cables, or individually screened multi pair cable, there is a specification to suit your exact requirements. Whatever the size of project, the company can ensure quick availability and competitive prices.

H07RN-F Cable to BS7919H07RN-F Cable to BS7919 Toggle

Eland Product Group: A6G and A5G

Application: These cables are designed to provide high flexibility and have the capacity to withstand weather, oils/greases, mechanical and thermal stresses. Applications include handling equipment, mobile power supplies, worksites, stage and audio visual equipment, port areas and dams. Also for use in drainage and water treatment, cold environments and severe industrial environments.

Read more about H07RN-F Cables and their applications.

Standards: BS7919, CENELEC HD22.4 S4

Full Product Specification

BS5308 Instrumentation Cable Part 1 Type 1BS5308 Instrumentation Cable Part 1 Type 1 Toggle

Eland Product Group: A3I

Application: BS5308 cables are used to carry voice and data services, they also serve as the interconnection between electrical equipment and instruments, particularly in and around process plants, where transducer generated signals are transmitted through to panels, controllers and other devices.

Standards: BS5308 Part 1, BS EN/IEC 60228

Full Product Specification

Cat 5E UTP PVC CableCat 5E UTP PVC Cable Toggle

Eland Product Group: A8N

Application: A multipair (usually 4 pair) high performance cable that consists of twisted pair conductors, used mainly for data transmission. Category 5E is recommended for all new and existing installations, supports a frequency range of up to 100MHz and is designed for transmission speeds of up to 1 gigabit per second (Gigabit Ethernet).

Read more about LAN Cables and the differences between these types of data cables.

Standards: ISO/IEC11801, TIA/EIA 568B

Full Product Specification

Overall Screened Multi-Core Cable  (Belden Equivalent)Overall Screened Multi-Core Cable (Belden Equivalent) Toggle

Eland Product Group: A3B

Application: Overall Screened Multi-Core Cable (Belden Equivalent) RS232 data cable is a general purpose overall screened cable. With protection against electrical interference, this cable is suitable for RS232 applications.

Standards: RS232

Full Product Specification

Overall Screened Multi-Pair Cable  (Belden Equivalent)Overall Screened Multi-Pair Cable (Belden Equivalent) Toggle

Eland Product Group: A3B

Application: Overall Screened Multi-Pair Cable (Belden Equivalent) provides protection against electrical interference. Suitable for use over long distances at high performance levels and where low signal distortion is required. Used for instrumentation control and RS232 applications.

Standards: RS232

Full Product Specification

Overall Foil and Braid Screened Cable  (Belden Equivalent)Overall Foil and Braid Screened Cable (Belden Equivalent) Toggle

Eland Product Group: A3B

Application: Overall Foil and Braid Screened Cable (Belden Equivalent) is a 24 AWG low capacitance cable with a high level of screening. Provides interference free, high speed data transmission suitable for RS485 applications.

Standards: RS485

Full Product Specification

Overall Screened Single Pair Cable  (Belden Equivalent)Overall Screened Single Pair Cable (Belden Equivalent) Toggle

Eland Product Group: A3B

Application: Overall Screened Single Pair Cable (Belden Equivalent) is suitable for use in instrumentation, data and audio applications where protection against electrical interference is required. Cables with polyethylene insulation show lower signal loss than those using PVC.

Conductor: Stranded tinned copper

Full Product Specification

Unscreened Single Pair Cable  (Belden Equivalent)Unscreened Single Pair Cable (Belden Equivalent) Toggle

Eland Product Group: A3B

Application: Unscreened Single Pair Cable (Belden Equivalent) is suitable for use in instrumentation, security, data, bus and audio applications where protection against electrical interference is not required.

Conductor: Stranded tinned copper

Full Product Specification

Individually Screened Multi-Pair Cable (Belden Equivalent)Individually Screened Multi-Pair Cable (Belden Equivalent) Toggle

Eland Product Group: A3B

Application: Individually Screened Multi-Pair Cable (Belden Equivalent) is designed to prevent cross-talk between pairs and ensures excellent protection from electrical interference. Suitable for instrumentation, computer and security applications, point of sale, control systems, and RS232 applications.

Conductor: Stranded tinned copper

Full Product Specification

Cat 5E UTP LSZH CableCat 5E UTP LSZH Cable Toggle

Eland Product Group: A8N

Application: A multipair (usually 4 pair) high performance cable that consists of twisted pair conductors, used mainly for data transmission. Category 5 E is recommended for all new and existing installations, supports a frequency range of up to 100MHz and is designed for transmission speeds of up to 1 gigabit per second (Gigabit Ethernet).

Read more about LAN Cables and the differences between these types of data cables.

Standards: ISO/IEC11801, TIA/EIA 568B

Full Product Specification

Cat 5E UTP PE External CableCat 5E UTP PE External Cable Toggle

Eland Product Group: A8N

Application: A multipair (usually 4 pair) high performance cable that consists of twisted pair conductors, used mainly for data transmission. Category 5 E is recommended for all new and existing installations, supports a frequency range of up to 100MHz and is designed for transmission speeds of up to 1 gigabit per second (Gigabit Ethernet). Cat 5E UTP is suitable for outdoor use.

Read more about LAN Cables and the differences between these types of data cables.

Standards: ISO/IEC 11801, TIA/EIA 568B

Full Product Specification

Cat 6 LSZH CableCat 6 LSZH Cable Toggle

Eland Product Group: A8N

Application: A multipair (usually 4 pair) high performance cable that consists of twisted pair conductors, used mainly for data transmission. Category 6 is recommended for all new and existing installations, supports a frequency range of up to 250MHz and is designed for transmission speeds of up to 1 gigabit per second (Gigabit Ethernet).

Read more about LAN Cables and the differences between these types of data cables.

Standards: ISO/IEC11801, TIA/EIA 568B

Full Product Specification

CW1308B Internal/External Telecom CableCW1308B Internal/External Telecom Cable Toggle

Eland Product Group: A8T

Application: Cables primarily designed for the interconnection of telephone equipment both internally and externally. In addition these cables may be used for the interconnection of other communication and control equipment or low level signalling applications. The cable specification is further enhanced by the use of a Low Smoke Zero Halogen outer sheath.

Standards: CW1308, IEC 60754-1

Full Product Specification

CW1308 Internal Telecom CableCW1308 Internal Telecom Cable Toggle

Eland Product Group: A8T

Application: Cables primarily designed for the interconnection of telephone equipment which is installed indoors. In addition these cables may be used for the interconnection of other communication and control equipment or low level signalling applications.

Standards: CW1308

Full Product Specification

CW1128/1198 Direct Burial Telephone CableCW1128/1198 Direct Burial Telephone Cable Toggle

Eland Product Group: A8T

Application: External armoured cable primarily designed for the interconnection of telephone equipment. Suitable for direct burial. UV and moisture resistant. In addition these cables may be used for interconnection of other communication and control equipment or low level signaling applications

Standards: CW1128/1198

Full Product Specification

CW1128 Telephone CableCW1128 Telephone Cable Toggle

Eland Product Group: A8T

Application: Cables primarily designed for the interconnection of telephone equipment. In addition these cables may be used for interconnection of other communication and control equipment or low level signalling applications.

Standards: CW1128

Full Product Specification

Coaxial CT CableCoaxial CT Cable Toggle

Eland Product Group: A7E

Application: Ideal for professional TV and CCTV system installations including digital satellite, terrestrial and Cable TV.

Which CT Cable is right for me?

Read more about Coaxial Cable.

Conductor: Solid plain copper

Full Product Specification

H07BN4-F Cable (6381TQ) to BS7919H07BN4-F Cable (6381TQ) to BS7919 Toggle

Eland Product Group: A6Q

Application: For connecting equipment such as pumps, generators and lighting to the mains supply and generally for use in arduous industrial environments where good flexibility and resistance to mechanical abrasion is essential.

Read more about H07BN4-F Cables and their applications.

Standards:
BS7919 (Superseded BS6007 in 2003)
CEI 20-19/13
20-35 (EN60332-1) / 20-22III (EN50266) / 20-37 (EN50267)
CENELEC HD22.13.S1/A1

Full Product Specification

6381 LSZH Cable6381 LSZH Cable Toggle

Eland Product Group: A1F LS

Application: Suitable for D.C. power supplies on Telecom equipment and power applications where flexibility is required. The cables produce no corrosive gases when burnt which is important where electronic equipment is installed.

Conductor: Class 5 flexible annealed plain copper conductors to BS EN 60228:2005 (previously BS6360)

Full Product Specification

 6381Y Cable to BS6004 6381Y Cable to BS6004 Toggle

Eland Product Group: A1F

Application: Suitable for AC and DC power supplies on Telecom equipment and power applications where flexibility is required.

Standards: Generally to BS6004, BS EN/IEC 60228

Full Product Specification

Multi-Core Data Cables to Def Stan 61/12 Part 5Multi-Core Data Cables to Def Stan 61/12 Part 5 Toggle

Eland Product Group: A2D

Application: These multicore flexible cables are designed for high density wiring between components and within instruments and electronic equipment. They are extensively used in aircraft, process control systems, computers, data processors, military vehicles and military equipment.

Standards: Generally to Def Stan 61-12 Part 5

Full Product Specification

Multi-Core Data Cables to Def Stan 61/12 Part 4Multi-Core Data Cables to Def Stan 61/12 Part 4 Toggle

Eland Product Group: A2D

Application: These Multi-Core flexible cables are designed for high density wiring between components and within instruments and electronic equipment. They are extensively used in aircraft, process control systems, computers, data processors, military vehicles and military equipment.

Standards: Generally to Def. Stan 61-12 Part 4

Full Product Specification

Twinaxial Cables (Belden Equivalent)Twinaxial Cables (Belden Equivalent) Toggle

Eland Product Group: A3B

Application: Paired computer cables. These cables were originally developed for I/O switching and process control applications and are now widely used in commercial applications for building management systems.

Conductor:
9207 LSF: 1 Tinned copper and 1 Bare Copper
9272 LSF: Tinned copper
9463 LSF: Tinned copper

Full Product Specification

BS5308 Instrumentation Cable Part 1 Type 2BS5308 Instrumentation Cable Part 1 Type 2 Toggle

Eland Product Group: A3I

Application: BS5308 cables are used to carry voice and data services, they also serve as the interconnection between electrical equipment and instruments, particularly in and around process plants, where transducer generated signals are transmitted through to panels, controllers and other devices.

Standards: BS5308 Part 1, BS EN/IEC 60228

Full Product Specification

Coaxial RG/URM/Composite CableCoaxial RG/URM/Composite Cable Toggle

Eland Product Group: A7E

Application: High quality RG Type Coaxial cables, 50 or 75 Ohm is suitable for many applications, including low power video, video signal, and broadband signals. Many types are available in Duct Grade, LSF or LSZH versions.

Conductor:
RG6: CCS (Copper Clad Steel)
RG11: TCW (Tinned Copper Wire)
RG58: TCW (Tinned Copper Wire)
RG59: CCS (Copper Clad Steel)
RG179: TCW (Tinned Copper Wire)
RG213 PVC: PCW (Plain Copper Wire)
RG213 LSZH: PCW (Plain Copper Wire)
URM67: PCW (Plain Copper Wire)
URM70: PCW (Plain Copper Wire)
75 Ohm Coax + 1Pair: PCW (Plain Copper Wire) + TCW (Tinned Copper Wire)
75 Ohm Coax + 1Pair: PCW (Plain Copper Wire) + TCW (Tinned Copper Wire)

Full Product Specification

Coaxial BT3002/RA7000 Eq. CableCoaxial BT3002/RA7000 Eq. Cable Toggle

Eland Product Group: A7E

Application: Manufactured to BT specifications and used for interconnecting of data or telecoms equipment.

Read more about Coaxial Cable.

Conductor: Solid plain copper

Full Product Specification

Cat 5E FTP PVC CableCat 5E FTP PVC Cable Toggle

Eland Product Group: A8N

Application: A multipair (usually 4 pair) high performance cable that consists of twisted pair conductors, used mainly for data transmission. Category 5E is recommended for all new and existing installations, supports a frequency range of up to 100MHz and is designed for transmission speeds of up to 1 gigabit per second (Gigabit Ethernet).

Read more about LAN Cables and the differences between these types of data cables.

Standards: ISO/IEC11801, TIA/EIA 568B

Full Product Specification

Individually Screened Multi-Pair Low Cap RS422 Cable (Belden Equivalent)Individually Screened Multi-Pair Low Cap RS422 Cable (Belden Equivalent) Toggle

Eland Product Group: A3B

Application: Individually Screened Multi-Pair Low Cap RS422 Cable (Belden Equivalent) is a low capacitance 24 AWG cable with protection against cross-talk, and is screened to ensure excellent protection from electrical interference. Suitable for CAD/CAM & RS422 applications. This cable is used widely in the security industry and in instrumentation, audio and computer applications, where there is a need for screening from external sources.

Standards: RS422

Full Product Specification

Cat 5E PE FTP GSWB LSZH CableCat 5E PE FTP GSWB LSZH Cable Toggle

Eland Product Group: A8N

Application: Also known as Armoured Cat 5E Cable, this cable is used for horizontal wiring in a local area network (LAN) in areas requiring mechanical protection.

Read more about LAN Cables and the differences between these types of data cables.

Standards: ISO/IEC11801, TIA/EIA 568B

Full Product Specification

H07ZZ-F CableH07ZZ-F Cable Toggle

Eland Product Group: A6G and A5G

Application: For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Examples of use include supplying mobile power units, UPS installations, stage lighting and audio visual equipment. This cable will withstand medium mechanical stresses and is suitable for both installation indoors and outdoors.

Standards:
CENELEC HD22-13
NFC 032-131
IEC 60332-3

Full Product Specification

Belden 9844 Multi-Conductor Low Capacitance Computer CableBelden 9844 Multi-Conductor Low Capacitance Computer Cable Toggle

Eland Product Group: A4B

Application: Used widely for audio, instrumentation and computer networks and for use in electronics. Also used for Controller Area Networks (CANopen solutions) which enable the communication between devices of different manufacturers and guarantee an interchangeability of devices.

Standards: EIA RS485

Full Product Specification

Belden 8162 Multi-Conductor Low Capacitance Computer CableBelden 8162 Multi-Conductor Low Capacitance Computer Cable Toggle

Eland Product Group: A4B

Application: Used widely in audio, process control, instrumentation and computer applications where there is a need for screening from external sources and low levels of cross-talk between pairs.

Standards: EIA RS232, RS422

Full Product Specification

Cat 5E 25 Pair UTP LSZH CableCat 5E 25 Pair UTP LSZH Cable Toggle

Eland Product Group: A8N

Application: This 25 pair LSZH backbone cable is suitable for 100Base-T, Gigabit Ethernet, 155 Mbps ATM, TP-PMD Audio, Multimedia and Telephone networks.

Read more about LAN Cables and the differences between these types of data cables.

Conductor: Class 1 solid plain copper

Full Product Specification

Cat 5E 25 Pair UTP RBS Duct Grade CableCat 5E 25 Pair UTP RBS Duct Grade Cable Toggle

Eland Product Group: A8N

Application: This 25 pair high performance backbone cable is suitable for outdoor use (in a duct). It can be installed in 100Base-T, Gigabit Ethernet, 155 Mbps ATM, TP-PMD Audio, Multimedia and Telephone networks.

Read more about LAN Cables and the differences between these types of data cables.

Conductor: Class 1 solid plain copper

Full Product Specification