Rail and Transport Industry

 Rail and Transport Industry A Link-up approved supplier, Eland Cables has a proven track record of supply to the rail industry, providing extensive knowledge and experience of working in partnership with Network Rail, and its approved contractors, to improve the safety and efficiency of UK rail infrastructure.

Eland’s expansive portfolio of Network Rail approved cables includes signalling, power, telecommunications, axle counter, points heating, overhead line and auxiliary cables. This range enables Eland to supply a broad spectrum of railway infrastructure projects from Signalling and Telecommunications to Electrification and Plant. In addition, Eland’s rail customers have the peace of mind that both Eland and our key supply partners are fully ISO 9001 accredited, allowing full batch traceability through the supply chain to the original source. (Refer to copies of accreditation, available upon request).

Eland has recently introduced additional cables to its range, specifically for main line and metro rolling stock and London Underground station track and signalling infrastructure, thus increasing its scope of supply even further.

In terms of service, to underpin its impressive range of rail cables, Eland offers just-in-time delivery to contractors that need to keep stockholding on site to a minimum – boasting an on-time delivery rate of over 98%. This allows customers to be sure that cable supply will not hold up project schedules. Furthermore, not only does Eland take your deadlines as seriously as you do, it can also offer a project-based cable cutting service which ultimately means less waste, faster installation and reduced costs on both skilled labour and materials. As rail projects increasingly focus on sustainability, reduced waste will also contribute to minimising environmental damage.

SWA Cable - BS5467 Steel Wire Armoured PVCSWA Cable - BS5467 Steel Wire Armoured PVC Toggle

Eland Product Group: A9S

Application: SWA Cable - power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting.

Standards: BS5467, IEC 60502

Full Product Specification

SWA Cable - BS5467 Steel Wire Armoured PVCSWA Cable - BS5467 Steel Wire Armoured PVC Toggle

Eland Product Group: A9S

Application: SWA Cable - power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting.

Standards: BS5467, IEC 60502

Full Product Specification

CY Control Flexible Cable to BS6500CY Control Flexible Cable to BS6500 Toggle

Eland Product Group: A5C

Application: Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use when temporarily moved, and in conditions of medium mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.

Standards: Generally to BS6500

Full Product Specification

CY LSZH Control Flexible Cable to BS6500CY LSZH Control Flexible Cable to BS6500 Toggle

Eland Product Group: A5B

Application: For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use when temporarily moved, and in conditions of medium mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.

Standards: Generally to BS6500, IEC 60754-1

Full Product Specification

YY Control Flexible Cable to BS6500YY Control Flexible Cable to BS6500 Toggle

Eland Product Group: A5Y

Application: Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.

Standards: Generally to BS6500, VDE0250

Full Product Specification

YY LSZH Control Flexible Cable to BS6500YY LSZH Control Flexible Cable to BS6500 Toggle

Eland Product Group: A5L

Application: For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.

Standards: Generally to BS6500, VDE0250, IEC 60332-3, IEC 60754-1

Full Product Specification

SY Control Flexible Cable to BS6500SY Control Flexible Cable to BS6500 Toggle

Eland Product Group: A5J

Application: Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
The braided screen offers the best possible protection against mechanical damage and offers a level of Electro-magnetic shielding. The galvanised coating helps protect against corrosion.

Standards: Generally to BS6500, VDE0250

Full Product Specification

SWA Cable - BS6724 Steel Wire Armoured LSZHSWA Cable - BS6724 Steel Wire Armoured LSZH Toggle

Eland Product Group: A9L

Application: SWA Cable - power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment.

Standards: BS6724, IEC 60754-1

Full Product Specification

Axle Counter CableAxle Counter Cable Toggle

Eland Product Group: A8A

Application: Axle Counter cable is used to connect the various elements of the AzLM Axle Counter System. It is suitable for installation in trackside cable troughing, buried duct route and installed in open air on the ballast and clipped to sleepers as required. Quad types XQS and XQZ are used to connect the EAK Junction box or termination to the EAK (Mushroom) and Multi Twisted pair types XPS and XPZ are used to connect EAK to the ACE (Axle Counter Evaluator) equipment.

Standards: NR/L2/SIG/30060

Full Product Specification

Copper Trackside Cable LSZHCopper Trackside Cable LSZH Toggle

Eland Product Group: A8T

Application: Suitable for installation in trackside cable troughing, and buried duct routes and generally in areas where smoke and toxic fumes may cause a threat to life and equipment. The cables produce no corrosive gasses when burnt which is particularly important where electronic equipment is installed.

PADS Approval: Certificate Number PA05/03862

Full Product Specification

Armoured Copper Trackside Cable LSZHArmoured Copper Trackside Cable LSZH Toggle

Eland Product Group: A8T

Application: Suitable for installation in trackside concrete cable troughing, buried duct route or for direct burial installations, and generally in areas where smoke and toxic fumes may cause a threat to life and equipment. The cables produce no corrosive gasses when burnt which is particularly important where electronic equipment is installed.

PADS Approval: Certificate Number PA05/03862

Full Product Specification

11kV XLPE LSZH Cable BS783511kV XLPE LSZH Cable BS7835 Toggle

Eland Product Group: A9M

Application: Power cables for power networks, underground, outdoors and in cable ducting. In particular for installation where fire, smoke emission and toxic fumes create a potential threat.

Standards: BS7835, IEC 60754-1

Full Product Specification

SWA Cable - BS6724 Steel Wire Armoured LSZHSWA Cable - BS6724 Steel Wire Armoured LSZH Toggle

Eland Product Group: A9L

Application: SWA Cable - power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment.

Standards: BS6724, IEC 60754-1

Full Product Specification

6491B Conduit Wiring Cable H07Z-R to BS72116491B Conduit Wiring Cable H07Z-R to BS7211 Toggle

Eland Product Group: A3Z

Application: Suitable for use in conduit and for fixed, protected installation. In particular for installation where fire, smoke emission and toxic fumes create a potential threat.

Standards: BS7211, BASEC approved*, BS EN/IEC 60228

Full Product Specification

Twin Datalink CableTwin Datalink Cable Toggle

Eland Product Group: A8T

Application: Interconnecting cable for Solid State Interlocking (SSI) systems.

Standards: BR1932

Full Product Specification

Trackfeeder CableTrackfeeder Cable Toggle

Eland Product Group: A3T

Application: Provides the 650/750 volt DC supply from Traction Substations and Track Paralleling Huts to conductor rails, negative cable connections and where appropriate, bonding

Standards: NR/PS/ELP/21101 (formerly RT/E/S/21101)

Full Product Specification

Signalling Cable Type A1, A2, A3Signalling Cable Type A1, A2, A3 Toggle

Eland Product Group: A5R

Application: Light Duty LSZH sheathed single and multi core generally for internal use. Smooth sheath suitable for installation in ducting

Standards: NR/PS/SIG/00005 (formerly RT/E/PS/00005)

Full Product Specification

Screening Conductor Cable PVCScreening Conductor Cable PVC Toggle

Eland Product Group: A3BR

Application: To be used for the purpose of screening telecommunication cables from electrical interference.

Standards: NR/PS/TEL/31102 (BR1817)/BS6485

Full Product Specification

Screening Conductor Cable LSZHScreening Conductor Cable LSZH Toggle

Eland Product Group: A3BR

Application: To be used for the purpose of screening telecommunication cables from electrical interference in areas where smoke and toxic fumes may cause a threat to life and equipment.

Standards: NR/PS/TEL/31102(BR1817)BS6485

Full Product Specification

SCADA / Pilot CableSCADA / Pilot Cable Toggle

Eland Product Group: A8T

Application: Paired core compound filled supervisiory cables for modem based supervisory systems operating in the VF range 300 to 3000 Hz.

Standards: NR/PS/ELP/27220 (formerly RT/E/PS/0034)

Full Product Specification

Points Heating CablePoints Heating Cable Toggle

Eland Product Group: A5RPH

Application: Designed for power distribution in points heating systems. These heavy duty cables offer protection from abrasion and mechanical impact whilst maintaining flexibility to ease installation.

Standards: NR/SP/ELP/40045 (formerly RT/E/PS/40045) BS7919

Full Product Specification

Junction BlocksJunction Blocks Toggle

Eland Product Group: A8B

Application: Designed for power distribution in railway points heating applications, the 4 way and 8 way jumper blocks offer a reliable method of connecting clamplock or strip heaters to their power supplies

Standards: NR/SP/ELP/40045 (formerly RT/E/S/40045)

Full Product Specification

MV Power CableMV Power Cable Toggle

Eland Product Group: A9M

Application: Cable used to distribute three phase a.c. electrical power supplies at nominal system voltages of 33kV to traction substations on D.C. electrified lines.

Standards: NR/PS/ELP/00008 (formerly RT/E/PS/00008) BS6622, BS6234, BS7454, IEC 60502-2, IEC 60840

Full Product Specification

Firecel SR 114E Enhanced Fire Cable PH120Firecel SR 114E Enhanced Fire Cable PH120 Toggle

Eland Product Group: A6F

Application: Firecel SR 114E Fire Performance Cable is intended for use in fire detection and fire alarm systems, and emergency lighting circuits. Firecel 114E Enhanced cable is recommended for situations where fire cables may need to remain operating correctly for a longer period than is expected of a standard fire cable. For example, in buildings without sprinkler systems, which have a longer evacuation process due to the size, complexity or purpose of the building, or any building that has been assessed as requiring enhanced fire protection.

Standards:
BS 5839-1:2002
Code of practice for fire system design, installation, commissioning and maintenance.

BS 7629-1:2008
Low emission of smoke and corrosive gases

BS EN 50200 PH120
Temperature: 830 °C
Flame and shock for 120 minutes

BS 8434-2:2003 +A2:2009
Temperature: 930 °C
Flame and shock for 60 minutes.
+ flame, shock and water for 60 minutes

BS 6387
Category C-W-Z
C - Resistance to fire at 950ºC for 3 hours
W - Resistance to fire with water at 950ºC for 3 hours
Z - Resistance to fire with mechanical shock at 950ºC for 3 hours

LPCB approved
LPCB Logo
Download Firecel SR 114E LPCB Certification as a pdf

Full Product Specification

Fibre Trackside CableFibre Trackside Cable Toggle

Eland Product Group: A8T

Application: Fibre communications cable for use in high traffic and data rate requirements.

Standards: NR/PS/TEL/00014 (formerly RT/E/PS/00014)

Full Product Specification

Festoon Cable - External H05RNH-FFestoon Cable - External H05RNH-F Toggle

Eland Product Group: A5F

Application: Flexible cords suitable for use in domestic premises, kitchens and offices. Also suitable for use in hot situations such as immersion heaters. Good resistance to oil and grease.

Standards: IEC 60598-1, H05RNH-F

Full Product Specification

Copper Trackside CableCopper Trackside Cable Toggle

Eland Product Group: A8T

Application: Suitable for installation in trackside concrete cable troughing or buried duct routes.

PADS Approval: Certificate Number PA05/03862

Full Product Specification

Bare ConductorBare Conductor Toggle

Eland Product Group: A3BR

Application: To be used for the purpose of screening telecommunication cables from electrical interference.

Standards: NR/PS/TEL/31102(BR1817)/BS6485

Full Product Specification

Armoured Fibre TracksideArmoured Fibre Trackside Toggle

Eland Product Group: A8T

Application: Armoured fibre communications cable for use in high traffic and data rate requirements

Standards: NR/PS/TEL/00014 (formerly RT/E/PS/00014)

Full Product Specification

Armoured Copper Trackside CableArmoured Copper Trackside Cable Toggle

Eland Product Group: A8T

Application: Suitable for installation in trackside concrete cable troughing, buried duct route or for direct burial installations.

PADS Approval: Certificate Number PA05/03862

Full Product Specification

Arctic Grade CableArctic Grade Cable Toggle

Eland Product Group: A5A

Application: Designed to withstand severe external temperatures remaining flexible at temperatures as low as -40°C. Arctic Grade PVC mains cords manufactured to BS7919 will remain flexible at temperatures down to minus 40°C making them particularly suitable for outdoor applications and for use where flexibility is required at sub zero temperatures. At normal temperatures the cable is very limp and flexible, offering some of the characteristics usually found in elastomeric cables.

Standards: BS7919 Table 44, VDE281

Full Product Specification

Aluminium Power CableAluminium Power Cable Toggle

Eland Product Group: A3T

Application: BR880 solid sector shaped conductors for trackside signalling power supplies.

Standards: BR880, BS5467, BS6346

Full Product Specification

6491X Cable H07V-R/H07V-U to BS60046491X Cable H07V-R/H07V-U to BS6004 Toggle

Eland Product Group: A2X

Application: 6491X Cable H07V-R/H07V-U to BS6004 is suitable for power and lighting circuits and building wiring. The cable is intended for use in semi-flush exposed conduits and embedded conduits as well as in closed installation ducts, and is ideal for the internal wiring of appliances and apparatus.

Standards: BS6004, BASEC approved*

Full Product Specification

6491B Conduit Wiring Cable H07Z-R to BS72116491B Conduit Wiring Cable H07Z-R to BS7211 Toggle

Eland Product Group: A3Z

Application: Suitable for use in conduit and for fixed, protected installation. In particular for installation where fire, smoke emission and toxic fumes create a potential threat.

Standards: BS7211, BASEC approved*, BS EN/IEC 60228

Full Product Specification

33kV XLPE Cable33kV XLPE Cable Toggle

Eland Product Group: A9M

Application: Power cables for power networks, underground, outdoors and in cable ducting.

Standards: BS6622

Full Product Specification

11kV XLPE PVC Cable11kV XLPE PVC Cable Toggle

Eland Product Group: A9M

Application: Power cables for power networks, underground, outdoors and in cable ducting.

Standards: BS6622, BS EN/IEC 60228

Full Product Specification

0361TQ Orange Welding Cable to BS6380361TQ Orange Welding Cable to BS638 Toggle

Eland Product Group: A1E

Application: For the transmission of high currents from the electric welding machine to the welding tool. Suitable for flexible use under rough conditions, on assembly lines and conveyor systems, in machine tool and motor car manufacturing, ship building, for manually and automatically operated line and spot welding machines.

Standards: BS638 Part 4* BS EN 60332-1-2

Full Product Specification

0361TQ Black Welding Cable to BS6380361TQ Black Welding Cable to BS638 Toggle

Eland Product Group: A1G

Application: For the transmission of high currents from the electric welding machine to the welding tool. Suitable for flexible use under rough conditions, on assembly lines and conveyor systems, in machine tool and motor car manufacturing, ship building, for manually and automatically operated line and spot welding machines.

Standards: BS638 Part 4* BS EN 60332-1-2

Full Product Specification

FTN Screening Conductor Cable PVCFTN Screening Conductor Cable PVC Toggle

Eland Product Group: A3BR

Application: To be used for the purpose of screening telecommunication cables from electrical interference.

Standards: NR/PS/TEL/31102 (BR1817)/BS6485

Full Product Specification

RIA21 CableRIA21 Cable Toggle

Eland Product Group: A6R

Application: Cables are designed for use in protected or exposed installation on traction and rolling stock within vehicles. May also find application in the connection of coil winding and flexible power leads.

Standards: RIA21

Full Product Specification

Signalling Cable Type B1, B2Signalling Cable Type B1, B2 Toggle

Eland Product Group: A5R

Application: Heavy Duty EPR insulated and Heavy Duty PCP sheathed single, twin and multicore cables

Standards: NR/PS/SIG/00005 (formerly RT/E/PS/00005)

Full Product Specification

Signalling Cable Type C1, C2, C3Signalling Cable Type C1, C2, C3 Toggle

Eland Product Group: A5R

Application: Heavy Duty Signalling cable suitable for tails

Standards: NR/PS/SIG/00005 (formerly RT/E/PS/00005)

Full Product Specification

Signalling Cable Type D1, D2Signalling Cable Type D1, D2 Toggle

Eland Product Group: A5R

Application: LSZH single, twin and multicore cables

Standards: NR/PS/SIG/00005 (formerly RT/E/PS/00005)

Full Product Specification

Signalling Cable Type E1, E2, E3Signalling Cable Type E1, E2, E3 Toggle

Eland Product Group: A5R

Application: LSZH signalling cable suitable for tails

Standards: NR/PS/SIG/00005 (formerly RT/E/PS/00005

Full Product Specification