Switchgear

Switchgear Eland Cables supplies a variety of flexible cables for use in switchgear systems. Eland’s switchgear cables are compliant with the highest national and international quality standards, giving buyers peace of mind that the products are of the quality they expect; a crucial factor for applications in facilities that supply critical services such as hospitals and water supply.

Switchgear can be found in a wide range of industries, as it is an essential part of power distribution systems, and the integration of circuit protection equipment. Switchgear is a combination of electrical disconnect switches, fuses or circuit breakers used to control and protect electrical equipment, as well as isolate the circuit if a fault condition should occur. It is an integral part of power distribution and for integration of a backup power source.

Eland's British Standard Coil End Lead is a flexible supply and distribution cable with a rugged construction. Coil End Lead has a tight bend Radii, which is a great advantage as many Switchgear installations have serious space restrictions, and flexibility is key to allow system designers greater freedom in the location of the system.

Tri-rated Cable is preferred for use within the switchgear unit. This high quality harmonised cable is approved to BS, UL and CSA standards, is ideally suited to panel wiring, and provides a reliable internal connection as part of switchgear. If you a looking for an LSZH (Low Smoke Zero Halogen) alternative for this application, Eland can supply you with 2491B/6701B. This is particularly useful in applications where there is a threat to human life in the event of a fire, or in data centres where electronic equipment would be harmed by the gases produced by a fire.

Eland also stocks a range of power cables to connect the external power system to the switchgear, and can recommend either SWA PVC Cable for fixed applications, or H07RN-F Cable for flexible applications.

SWA Cable - BS5467 Steel Wire Armoured PVCSWA Cable - BS5467 Steel Wire Armoured PVC Toggle

Eland Product Group: A9S

Application: SWA Cable - power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting.

Standards: BS5467, IEC 60502

Full Product Specification

Tri-rated Cable (H07V2-K) to BS6231Tri-rated Cable (H07V2-K) to BS6231 Toggle

Eland Product Group: A2T

Application: Tri-rated Cable panel wiring is a high temperature, flame retardant cable designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers. Tri-rated Cable is sometimes referred to as BS6231 Cable, H07V2-K or Panel Wire.

Standards:
BS6231 Type CK
UL Subj.758
CSA c.22.2 No. 127 (only applicable for sizes up to 120mm²)
HD 21.7 S2*

Full Product Specification

H07RN-F Cable to BS7919H07RN-F Cable to BS7919 Toggle

Eland Product Group: A6G and A5G

Application: These cables are designed to provide high flexibility and have the capacity to withstand weather, oils/greases, mechanical and thermal stresses. Applications include handling equipment, mobile power supplies, worksites, stage and audio visual equipment, port areas and dams. Also for use in drainage and water treatment, cold environments and severe industrial environments.

Read more about H07RN-F Cables and their applications.

Standards: BS7919, CENELEC HD22.4 S4

Full Product Specification

Coil End Lead Cable to BS6195Coil End Lead Cable to BS6195 Toggle

Eland Product Group: A6K

Application: Coil leads are used mainly in electrical machinery and panel wiring. The HOFR sheath resists oil and varnish and the stranding is designed as a compromise between flexibility and positional stability. Also suitable as an alternative to tri-rated and bi-rated cable in certain applications.

Standards: BS6195 Type 4

Full Product Specification

2491B / 6701B Flexible Cable H05Z-K/H07Z-K to BS72112491B / 6701B Flexible Cable H05Z-K/H07Z-K to BS7211 Toggle

Eland Product Group: A2Z

Application: In pipes or ducts and internal wiring of appliances with maximum operating temperatures of 90°C, and generally in areas (such as public and government buildings) where smoke and toxic fumes may cause a threat to life and equipment. The cables produce no corrosive gasses when burnt which is particularly important where electronic equipment is installed.

Standards: BS7211, CENELEC HD22.9, IEC 60332-3-24

Full Product Specification

NSGAFOU CableNSGAFOU Cable Toggle

Eland Product Group: A5N

Application: Single core cable for use in switch cabinets, wiring of devices, trains and buses as well as in dry rooms.

Standards: DIN VDE 0250-602

Full Product Specification