With expert knowledge of supplying cables to major water treatment projects across the world, Eland Cables provides a high quality portfolio of cables designed to meet the exacting standards of the water industry.
Whether connecting equipment such as pumps to the mains supply or supplying non-toxic, waterproof cables for potable water applications, Eland has a solution that installers can rely on. From water treatment plants, to drainage and dams, the company supplies a wide range of high flexibility cables capable of withstanding extreme weather conditions, mechanical and thermal stresses, mechanical abrasion, as well as chemicals used in the water purification process. Solutions include low smoke zero halogen power cables for installation where fire, smoke emission and toxic fumes create a potential threat; steel wire armoured cable; specialist potable cable and much more.
SWA Cable - BS5467 Steel Wire Armoured PVC
Toggle
Eland Product Group: A9S
Application: SWA Cable - power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting.
Standards: BS5467, IEC 60502
H07RN-F Cable to BS7919
Toggle
Eland Product Group: A6G and A5G
Application: These cables are designed to provide high flexibility and have
the capacity to withstand weather,
oils/greases, mechanical and thermal stresses. Applications include handling equipment, mobile power supplies, worksites, stage and audio visual equipment, port areas and dams. Also for use in drainage and water treatment, cold environments and severe industrial environments.
Read more about H07RN-F Cables and their applications.
Standards: BS7919, CENELEC HD22.4 S4
BS5308 Instrumentation Cable Part 1 Type 1
Toggle
Eland Product Group: A3I
Application: BS5308 cables are used to carry voice and data services, they also serve as the interconnection between electrical equipment and instruments, particularly in and around process plants, where transducer generated signals are transmitted through to panels, controllers and other devices.
Standards: BS5308 Part 1, BS EN/IEC 60228
SWA Cable - BS6724 Steel Wire Armoured LSZH
Toggle
Eland Product Group: A9L
Application: SWA Cable - power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment.
Standards: BS6724, IEC 60754-1
11kV XLPE PVC Cable
Toggle
Eland Product Group: A9M
Application: Power cables for power networks, underground, outdoors and in cable ducting.
Standards: BS6622, BS EN/IEC 60228
11kV XLPE LSZH Cable BS7835
Toggle
Eland Product Group: A9M
Application: Power cables for power networks, underground, outdoors and in cable ducting. In particular for installation where fire, smoke emission and toxic fumes create a potential threat.
Standards: BS7835, IEC 60754-1
BS5308 Instrumentation Cable Part 1 Type 2
Toggle
Eland Product Group: A3I
Application: BS5308 cables are used to carry voice and data services, they also serve as the interconnection between electrical equipment and instruments, particularly in and around process plants, where transducer generated signals are transmitted through to panels, controllers and other devices.
Standards: BS5308 Part 1, BS EN/IEC 60228
H07BN4-F Cable (6381TQ) to BS7919
Toggle
Eland Product Group: A6Q
Application: For connecting equipment such as pumps, generators and lighting to the mains supply and generally for use in arduous industrial environments where good flexibility and resistance to mechanical abrasion is essential.
Read more about H07BN4-F Cables and their applications.
Standards:
BS7919 (Superseded BS6007 in 2003)
CEI 20-19/13
20-35 (EN60332-1) / 20-22III (EN50266) / 20-37 (EN50267)
CENELEC HD22.13.S1/A1
H07ZZ-F Cable
Toggle
Eland Product Group: A6G and A5G
Application: For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Examples of use include supplying mobile power units, UPS installations, stage lighting and audio visual equipment. This cable will withstand medium mechanical stresses and is suitable for both installation indoors and outdoors.
Standards:
CENELEC HD22-13
NFC 032-131
IEC 60332-3